SETECNA EPC S.r.l. Modbus templates
All 5 available SETECNA EPC S.r.l. templates for ModbusCloud.
Flush-mount SETECNA EPC temperature and humidity sensors plus a Modbus-to-OpenTherm gateway via Modbus RTU.
- Templates
- 5
- Connection
- Modbus RTU
- Registers
- 4 to 23 per template
- Compatible models
- MB-THL-SXX · MB-TH-SXX · MB-THL-9K6 · MB-OTG · MB-TH-9K6-SXX
- Last updated
SETECNA EPC S.r.l. templates
5 via Modbus RTU
Flush-mounting microprocessor sensors for ambient temperature and humidity measurement with display baud rate 19200Measures ambient temperature and humidity with LED display and setpoint controlModbus RTU6 read, 8 write
Flush-mounting microprocessor sensors for ambient temperature and humidity measurement baud rate 19200Measures ambient temperature and humidity via flush-mounted microprocessor sensor.Modbus RTU4 read, 2 write
Flush-mounting microprocessor sensors for ambient temperature and humidity measurement with display baud rate 9600Measures ambient temperature and humidity with setpoint and mode control via Modbus RTUModbus RTU6 read, 8 write
MB-OTG 1-Channel Modbus-to-OpenTherm GatewayBridges Modbus RTU to OpenTherm for boiler monitoring and controlModbus RTU21 read, 5 write
Flush-mounting microprocessor sensors for ambient temperature and humidity measurement baud rate 9600Measures ambient temperature and humidity via flush-mounted microprocessor sensor.Modbus RTU4 read, 2 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

SETECNA EPC S.r.l. is an Italian building-automation specialist producing flush-mount microprocessor sensors and gateways designed to integrate into civil wiring series such as BTicino, Vimar, Gewiss and ABB. The 5 SETECNA EPC Modbus RTU templates in our library cover flush-mount temperature and humidity sensors at 9600 and 19200 baud (with and without LED display variants) and the MB-OTG 1-channel Modbus-to-OpenTherm gateway.
With ModbusCloud and these SETECNA EPC Modbus RTU templates you read temperature with 0.1 °C resolution and relative humidity with 0.1 % RH resolution, and you apply calibration offsets per register. The display variants accept temperature setpoints, seasonal limit parameters and touch-button configuration remotely. The MB-OTG gateway bridges OpenTherm boilers to Modbus RTU, exposing boiler flow/return temperatures, modulation level and alarms plus writable setpoints and enable controls.
All 5 SETECNA EPC templates are free to browse. Import one into your ModbusCloud portal to integrate Italian civil-series room sensors and OpenTherm heat generators into a single Modbus dashboard.
What you can read out
- Temperature (0.1 °C resolution)
- Relative humidity (0.1 % RH resolution)
- Boiler modulation level (MB-OTG)
- Boiler flow and return temperatures
- OpenTherm alarm status
Typical installations
- Italian residential retrofits with civil-series flush-mount sensors
- OpenTherm boiler integration into commercial BMS
- Hospitality rooms with touch-button setpoint adjustment
Want to see how it works?