KOSTAL KOSTAL PLENTICORE plus Modbus TCP template

KOSTAL PLENTICORE plus

Hybrid PV inverter with battery input, power control and energy meter values over Modbus TCP.

The KOSTAL PLENTICORE plus is a three-phase hybrid inverter that converts solar power, charges and discharges a home battery and reads a grid energy meter. This Modbus TCP template reads PV, AC, battery, grid and home consumption values and yield counters, and lets you write power limits, battery setpoints and SOC limits from ModbusCloud.

Protocol
Modbus TCP
Connection
Ethernet, Modbus TCP
Registers
157, read and write
Brand
KOSTAL
Key readings
PV power per string · AC active power · Battery state of charge · Battery power · Grid power · Home consumption · Daily and total yield
Available commands
Active power limit · Battery charge power · Battery charge and discharge limits · Minimum and maximum SOC · Switched outputs
Compatible models
PLENTICORE plus · PLENTICORE plus G2 · PLENTICORE G3 · PLENTICORE MP G3 · PLENTICORE BI · PIKO IQ
Last updated

Registers (157)

156 read, 27 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Total DC PowerWRead
Total AC Active PowerWRead
Total AC Reactive PowervarRead
Total AC Apparent PowerVARead
Grid FrequencyHzRead
Actual Cos PhiRead
Phase 1 CurrentARead
Phase 1 Active PowerWRead
Phase 1 VoltageVRead
Phase 2 CurrentARead
Phase 2 Active PowerWRead
Phase 2 VoltageVRead
Phase 3 CurrentARead
Phase 3 Active PowerWRead
Phase 3 VoltageVRead
DC1 CurrentARead
DC1 PowerWRead
DC1 VoltageVRead
DC2 CurrentARead
DC2 PowerWRead
DC2 VoltageVRead
DC3 CurrentARead
DC3 PowerWRead
DC3 VoltageVRead
Home Consumption From PVWRead
Home Consumption From BatteryWRead
Home Consumption From GridWRead
Total Home Consumption Rate%Read
Battery State Of Charge%Read
Battery Actual SOC%Read
Battery Charge Discharge PowerWRead
Battery Charge Discharge CurrentARead
Battery Charge CurrentARead
Battery VoltageVRead
Battery Temperature°CRead
Battery CyclesRead
Battery Ready FlagRead
PSSB Fuse StateRead
Battery Gross CapacityRead
Battery Work CapacityWhRead
Battery Work Capacity FloatWhRead
Max Charge Power From BatteryWRead
Max Discharge Power From BatteryWRead
Battery TypeRead
Battery Management ModeRead
Installed Sensor TypeRead
Meter Total Active PowerWRead
Meter Total Reactive PowervarRead
Meter Total Apparent PowerVARead
Meter FrequencyHzRead
Meter Cos PhiRead
Meter Phase 1 CurrentARead
Meter Phase 1 Active PowerWRead
Meter Phase 1 Reactive PowervarRead
Meter Phase 1 Apparent PowerVARead
Meter Phase 1 VoltageVRead
Meter Phase 2 CurrentARead
Meter Phase 2 Active PowerWRead
Meter Phase 2 Reactive PowervarRead
Meter Phase 2 Apparent PowerVARead
Meter Phase 2 VoltageVRead
Meter Phase 3 CurrentARead
Meter Phase 3 Active PowerWRead
Meter Phase 3 Reactive PowervarRead
Meter Phase 3 Apparent PowerVARead
Meter Phase 3 VoltageVRead
Inverter StateRead
Energy Manager StateRead
Controller PCB Temperature°CRead
Isolation ResistanceΩRead
Power Limit From EVU%Read
Active Power Setpoint%Read and write
Reactive Power Setpoint%Read and write
Delta Cos Phi SetpointRead and write
Low Priority Active Power SetpointWWrite
Low Priority Setpoint Scale FactorRead
Battery Charge Power AC SetpointWRead and write
Battery Power Scale FactorRead
Battery Charge Power AC AbsoluteWRead and write
Battery Charge Current DC Relative%Read and write
Battery Charge Power AC Relative%Read and write
Battery Charge Current DC AbsoluteARead and write
Battery Charge Power DC AbsoluteWRead and write
Battery Charge Power DC Relative%Read and write
Battery Max Charge Power LimitWRead and write
Battery Max Discharge Power LimitWRead and write
Minimum SOC%Read and write
Maximum SOC%Read and write
Max Battery Charge PowerWRead and write
Max Battery Discharge PowerWRead and write
Max Battery Charge Power FallbackWRead and write
Max Battery Discharge Power FallbackWRead and write
Time Until FallbacksRead and write
Switched Output 1Read and write
Switched Output 2Read and write
Switched Output 3Read and write
Switched Output 4Read and write
Modbus EnableRead and write
Modbus Unit IDRead and write
Modbus Byte OrderRead and write
Total YieldWhRead
Daily YieldWhRead
Monthly YieldWhRead
Yearly YieldWhRead
Total Home ConsumptionWhRead
Total Home Consumption PVWhRead
Total Home Consumption BatteryWhRead
Total Home Consumption GridWhRead
Total DC Charge EnergyWhRead
Total DC Discharge EnergyWhRead
Total AC Charge EnergyWhRead
Total AC Discharge Energy To GridWhRead
Total AC Charge Energy From GridWhRead
Total DC PV EnergyWhRead
Total DC Energy PV1WhRead
Total DC Energy PV2WhRead
Total DC Energy PV3WhRead
Total Energy AC To GridWhRead
Total DC Power SumWRead
Total Real Energy ExportedWhRead
Total Real Energy ImportedWhRead
WorktimesRead
Generation PowerWRead
Power Scale FactorRead
Generation EnergyWhRead
Energy Scale FactorRead
Inverter Max PowerWRead
Inverter Max Power Scale FactorRead
Inverter Article NumberRead
Inverter Serial NumberRead
Number Of Bidirectional ConvertersRead
Number Of AC PhasesRead
Number Of PV StringsRead
Hardware VersionRead
Software Version MCRead
Software Version IOCRead
Power IDRead
Overall Software VersionRead
Inverter Network NameRead
IP EnableRead
Manual IP Or Auto IPRead
IP AddressRead
IP Subnet MaskRead
IP GatewayRead
IP Auto DNSRead
IP DNS1Read
IP DNS2Read
Firmware MaincontrollerRead
Battery ManufacturerRead
Battery Model IDRead
Battery Serial NumberRead
Battery Serial Number BMRead
Battery FirmwareRead
Inverter ManufacturerRead
Inverter Serial Number LongRead
Product NameRead
Power ClassRead

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Show PV, battery, grid and home power of one installation on a single ModbusCloud dashboard.
  • Get an email alert when the battery state of charge stays below a threshold or the inverter state changes to a fault.
  • Compare daily yield per PV input in the history to spot a shaded or failing string.
  • Set a feed-in limit or battery charge limit remotely when the grid operator or the customer asks for it.
  • Export a year of yield and battery energy counters as CSV for a performance report.

Installation

  1. Connect the inverter LAN port to the network where the ModbusCloud Gateway is connected, and give the inverter a fixed IP address.

  2. In the inverter web interface, enable Modbus/SunSpec (TCP) and keep the byte order on little-endian (CDAB).

  3. In ModbusCloud, add a Modbus TCP device with the inverter IP address, port 1502 and unit ID 71, then import this template.

  4. Check that Total AC Active Power and Battery State Of Charge show plausible values.

  5. For battery control, select external battery management via Modbus in the inverter before you write battery setpoints.

Things to watch for

The Gateway gets no answer from the inverter. What should I check?

Check that Modbus/SunSpec (TCP) is enabled in the inverter web interface, that you use port 1502 and not 502, and unit ID 71 unless it was changed. The inverter and the ModbusCloud Gateway must be in the same network, and the inverter needs a fixed IP address.

Why do all power and energy values look like nonsense?

The values are 32-bit floats and their word order follows the byte order setting in the inverter. This template expects the default little-endian (CDAB). If someone switched the inverter to big-endian (ABCD) for SunSpec, set it back or change the word order of the registers.

Why does writing a battery setpoint have no effect?

The inverter only follows battery setpoints when external battery management via Modbus is selected in its settings; Battery Management Mode then reads External via Modbus. Writing registers from ModbusCloud is off per gateway by default and is switched on by request on the control tab.

Why does the battery charge limit fall back after a while?

Max Battery Charge Power and Max Battery Discharge Power must be rewritten before Time Until Fallback runs out (30 to 10800 seconds); then the fallback limits apply. Set Time Until Fallback longer than your write interval, for example with a scheduled automation in ModbusCloud.

Are power limits kept after a restart?

No. The active power, reactive power and cos phi setpoints are not stored and the inverter drops them when it restarts or resets. Write them again after a restart if you need them, and check the grid code before you change reactive power or cos phi.