ONOKOM AIR ME-1-MB-B
Controls Mitsubishi Electric air conditioners via the ONOKOM ME-1-MB-B gateway over Modbus RTU.
This template connects Mitsubishi Electric air conditioners via the ONOKOM ME-1-MB-B gateway over Modbus RTU. It reads indoor temperature and AC status, and provides control over operation mode, fan speed, target temperature, and vane positions.
- Protocol
- Modbus RTU
- Connection
- RS485, 9600 baud
- Registers
- 11, read and write
- Brand
- Onokom
- Key readings
- Indoor air temperature · AC connected · Quiet mode status · Vertical vanes status · Horizontal vanes status
- Available commands
- Target temperature · Active (on/off) · Smart fan speed · Operation mode
- Compatible models
- ONOKOM ME-1-MB-B
- Last updated
Registers (11)
5 read, 9 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| Indoor air temperature | °C | Read | |||
| AC connected | Read | ||||
| Quiet mode (Status) | Read and write | ||||
| Vertical vanes (Status) | Read and write | ||||
| Horizontal vanes | Read and write | ||||
| Active (Control) | Write | ||||
| Loxone modes (Control) | Write | ||||
| Smart fan speed | Write | ||||
| Target temperature | °C | Write | |||
| Vanes swing | Write | ||||
| Modbus address (Service) | Write |
Loading registers…
Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Monitor indoor air temperature and AC status remotely on a live ModbusCloud dashboard.
- Control target temperature and operation mode for Mitsubishi Electric AC units from any location.
- Create an alert when the indoor temperature deviates more than 2 degrees from the setpoint.
- Adjust fan speed and vane positions remotely to optimize comfort without a site visit.
- Track quiet mode status across multiple AC units in a multi-zone commercial building.
- Log historical temperature and operating mode data for energy analysis and reporting.
Installation
Connect the ONOKOM ME-1-MB-B gateway to the Mitsubishi Electric indoor unit using the AC unit's communication port as described in the ONOKOM installation manual.
Wire the Modbus RTU lines (A, B, and GND) from the ONOKOM ME-1-MB-B to the RS-485 port on your ModbusCloud Gateway.
Set the baud rate on the ModbusCloud gateway to 9600 to match the ONOKOM ME-1-MB-B default settings.
If multiple ONOKOM gateways share the same bus, assign each a unique Modbus address using service register 128.
Import the ONOKOM AIR ME-1-MB-B template from the ModbusCloud template library and assign it to the correct Modbus address.
Verify communication by checking that indoor air temperature and AC connection status appear on the ModbusCloud dashboard.
Things to watch for
How do I change the Modbus address of the ONOKOM ME-1-MB-B?
Write the desired address to service register 128 on the gateway. This is necessary when multiple ONOKOM gateways are connected on the same Modbus RTU bus to avoid address conflicts.
What baud rate should I use?
The default baud rate is 9600. Make sure your ModbusCloud gateway RS-485 port is also configured to 9600 baud, 8 data bits, no parity, and 1 stop bit (8N1) unless the ONOKOM documentation specifies otherwise.
Can I control vane positions and quiet mode, or are they read-only?
The quiet mode, vertical vane, and horizontal vane registers are both readable and writable. You can monitor their current state and change them remotely through the template.
Do I need one ONOKOM gateway per air conditioner?
Yes. Each ONOKOM ME-1-MB-B gateway connects to a single Mitsubishi Electric indoor unit. For multi-unit installations, use one gateway per AC unit and assign unique Modbus addresses.
Want to see how it works?