Onokom Modbus templates
All 21 available Onokom templates for ModbusCloud.
Connect AUX, Daikin, Midea, Mitsubishi, Hisense and other AC brands to your BMS via ONOKOM Modbus RTU gateways.
- Templates
- 21
- Connection
- Modbus RTU
- Registers
- 8 to 513 per template
- Compatible models
- ONOKOM HS-3-MB-B · ONOKOM MD-3-MB-B · ONOKOM MH-2-MB-B · ONOKOM GR-1-MB-B · ONOKOM HR-1-MB-B · MD-VRF-MB-B · ONOKOM AIR HT-1-MB-B · TCL-6-MB-B · ONOKOM AUX-1-MB-B · ONOKOM HS-6-MB-B · ONOKOM ME-1-MB-B · ONOKOM MD-1-MB-B · ONOKOM DK-5-MB-B · ONOKOM GR-3-MB-B · ONOKOM HS-VRF-MB-B · ONOKOM DK-1-MB-B · CG-VRF-MB-B · ONOKOM HS-5-MB-B · TCL-1-MB-B · ONOKOM TN-1-MB-B · Tion 4S · ONOKOM TCL-3-MB-B
- Last updated
Onokom templates
21 via Modbus RTU
ONOKOM AIR HS-3-MB-BControls Hisense air conditioners via the ONOKOM HS-3-MB-B Modbus gateway.Modbus RTU14 read, 12 write
ONOKOM AIR MD-3-MB-BControls Midea air conditioners via the ONOKOM MD-3-MB-B Modbus gateway.Modbus RTU9 read, 8 write
ONOKOM AIR MH-2-MB-BControls Mitsubishi Heavy air conditioners via the ONOKOM MH-2-MB-B Modbus gateway.Modbus RTU5 read, 8 write
ONOKOM AIR GR-1-MB-BControls Gree air conditioners via the ONOKOM GR-1-MB-B Modbus gateway.Modbus RTU12 read, 15 write
ONOKOM AIR HR-1-MB-BControls Haier air conditioners via the ONOKOM HR-1-MB-B Modbus gateway.Modbus RTU11 read, 14 writeONOKOM AIR MD-VRF-MB-BControls Midea air conditioners via the ONOKOM MD-VRF-MB-B gatewayModbus RTU0 read, 0 write
ONOKOM AIR HT-1-MB-BControls Hitachi air conditioners via the ONOKOM HS-3-MB-B gateway over Modbus RTU.Modbus RTU3 read, 5 write
ONOKOM AIR TCL-6-MB-BControls TCL air conditioners via the ONOKOM TCL-6-MB-B Modbus gateway.Modbus RTU9 read, 11 write
ONOKOM AIR AUX-1-MB-BControls AUX air conditioners via the ONOKOM AUX-1-MB-B Modbus gatewayModbus RTU13 read, 15 write
ONOKOM AIR HS-6-MB-BControls Hisense air conditioners via the ONOKOM HS-6-MB-B Modbus gateway.Modbus RTU5 read, 7 write
ONOKOM AIR ME-1-MB-BControls Mitsubishi Electric air conditioners via the ONOKOM ME-1-MB-B gateway over Modbus RTU.Modbus RTU5 read, 9 write
ONOKOM AIR MD-1-MB-BControls Midea air conditioners via the ONOKOM MD-1-MB-B Modbus gateway.Modbus RTU5 read, 8 write
ONOKOM AIR DK-5-MB-BControls Daikin air conditioners via the ONOKOM DK-5-MB-B Modbus gateway.Modbus RTU6 read, 7 write
ONOKOM AIR GR-3-MB-BControls Gree air conditioners via the ONOKOM GR-3-MB-B Modbus gateway.Modbus RTU15 read, 14 write
ONOKOM AIR HS-VRF-MB-BControls Hisense VRF air conditioners via the ONOKOM HS-VRF-MB-B gateway over Modbus RTU.Modbus RTU192 read, 385 write
ONOKOM AIR DK-1-MB-BControls Daikin air conditioners via the ONOKOM DK-1-MB-B Modbus gateway.Modbus RTU12 read, 13 writeONOKOM AIR CG-VRF-MB-BControls Chigo air conditioners via the ONOKOM CG-VRF-MB-B gatewayModbus RTU0 read, 0 write
ONOKOM AIR HS-5-MB-BControls Hisense air conditioners via the ONOKOM HS-5-MB-B Modbus gateway.Modbus RTU4 read, 8 write
ONOKOM AIR TCL-1-MB-BControls TCL air conditioners via the ONOKOM TCL-1-MB-B Modbus gateway.Modbus RTU22 read, 19 write
ONOKOM AIR TN-1-MB-BControls a Tion 4S breezer via ONOKOM TN-1-MB-B Modbus gatewayModbus RTU16 read, 12 write
ONOKOM AIR TCL-3-MB-BControls TCL air conditioners via the ONOKOM TCL-3-MB-B Modbus gateway.Modbus RTU10 read, 13 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

ONOKOM is a Russian OEM that makes Modbus RTU bridge gateways for a wide range of air conditioner brands. The MB-B series lets a single ONOKOM gateway translate the proprietary bus of an AC brand, Hisense HS, Daikin DK, Midea MD, Mitsubishi Heavy MH, Gree GR, TCL, Haier HR, AUX, Hitachi, into standard Modbus RTU registers that any BMS or monitoring platform can read. Because the protocol translation happens inside the gateway, the AC itself keeps its native controls and warranty.
With ModbusCloud, an ONOKOM gateway gives you remote visibility into indoor and outdoor temperatures, AC connection status, error codes, fan speed, vane positions, and operating mode. Modbus RTU writes let you set modes, fan speed, vanes, and target temperature for each connected unit. For VRF/VRV variants (HS-VRF, MD-VRF, CG-VRF), a single ONOKOM gateway exposes up to 64 indoor units as separate addressable register blocks.
All 21 ONOKOM templates are free to browse. Import one with a click into your ModbusCloud portal to start reading live AC data within minutes, no protocol reverse-engineering, no register hunting through manufacturer PDFs.
What you can read out
- Indoor and outdoor air temperatures
- Operating mode and fan speed status
- Error codes and AC connection status
- Vane position per indoor unit
- Target temperature setpoint
Typical installations
- Multi-tenant buildings where each tenant runs a different AC brand
- Commercial VRF installations with mixed AC manufacturers
- Retail and office fit-outs where the AC was specified before the BMS