Schneider Electric Altivar ATV340 configuration and settings
Drive setup of the Altivar ATV340: motor data, ramps, speed limits, I/O, PID and protections.
The Schneider Electric Altivar ATV340 is a variable speed drive for machines such as conveyors, hoists and packaging lines. This Modbus RTU template reads its configuration, from motor data and ramps to I/O assignment, PID and protections, and lets you change those settings from ModbusCloud.
- Protocol
- Modbus RTU
- Connection
- RS485, 19200 baud
- Registers
- 937, read and write
- Brand
- Schneider Electric
- Key readings
- Low and high speed · Acceleration and deceleration · Motor nominal data · Input and output assignment · PID settings · Fault handling settings
- Available commands
- Speed limits · Ramp times · Motor parameters · I/O assignment · PID setpoints · Protection settings
- Compatible models
- Altivar Machine ATV340 · Schneider Electric Altivar Machine ATV340 variable speed drive
- Last updated
Registers (937)
937 read, 898 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| Low Speed (LSP) | Hz | Read and write | 3105 | FC03 / FC06 | uint16 |
| High Speed (HSP) | Hz | Read and write | 3104 | FC03 / FC06 | uint16 |
| High Speed 2 (HSP2) | Hz | Read and write | 15110 | FC03 / FC06 | uint16 |
| High Speed 3 (HSP3) | Hz | Read and write | 15111 | FC03 / FC06 | uint16 |
| High Speed 4 (HSP4) | Hz | Read and write | 15112 | FC03 / FC06 | uint16 |
| 2 High Speed Assign. (SH2) | Read and write | ||||
| 4 High Speed Assign. (SH4) | Read and write | ||||
| Motor Thermal Current (ITH) | Read and write | ||||
| Inertia Factor (SPGU) | % | Read and write | |||
| Speed Proportional Gain (SPG) | % | Read and write | |||
| Speed Time Integral (SIT) | ms | Read and write | |||
| K Speed Loop Filter (SFC) | Read and write | ||||
| Inertia Coefficient Of The Application (JACO) | Read and write | ||||
| Speed Loop Type (SSL) | Read and write | ||||
| Estimated Application Inertia (JEST) | Read | ||||
| Application Inertia (JAPL) | Read and write | ||||
| Inertia Multiplying Coefficient (JMUL) | Read | ||||
| Feed Forward Value (FFP) | % | Read and write | |||
| Feed Forward Bandwidth (FFV) | % | Read and write | |||
| Filter Time Of The Estimated Speed (FFH) | ms | Read and write | |||
| Filter Time Of The Current (CRTF) | ms | Read and write | |||
| Notch Filter Activation (NFA) | Read and write | ||||
| Notch Filter 1 - Frequency (NFF1) | Hz | Read and write | |||
| Notch Filter 1 - Bandwidth (NFB1) | % | Read and write | |||
| Notch Filter 1 - Depth (NFD1) | % | Read and write | |||
| Notch Filter 2 - Frequency (NFF2) | Hz | Read and write | |||
| Notch Filter 2 - Bandwidth (NFB2) | % | Read and write | |||
| Notch Filter 2 - Depth (NFD2) | % | Read and write | |||
| High Current Threshold (CTD) | Read and write | ||||
| High Torque Threshold (TTH) | % | Read and write | |||
| Low Torque Threshold (TTL) | % | Read and write | |||
| Pulse Warning Threshold (FQL) | Hz | Read and write | |||
| Motor Frequency Threshold (FTD) | Hz | Read and write | |||
| Frequency Threshold 2 (F2D) | Hz | Read and write | |||
| Skip Frequency 2 (JF2) | Hz | Read and write | |||
| Skip Frequency (JPF) | Hz | Read and write | |||
| Skip Freq. Hysteresis (JFH) | Hz | Read and write | |||
| 3rd Skip Frequency (JF3) | Hz | Read and write | |||
| Motor Standard (BFR) | Read and write | ||||
| Nominal Motor Power (NPR) | Read and write | ||||
| Motor 1 Cosinus Phi (COS) | Read and write | ||||
| Nominal Motor Voltage (UNS) | V | Read and write | |||
| Nominal Motor Current (NCR) | Read and write | ||||
| Nominal Motor Frequency (FRS) | Hz | Read and write | |||
| Nominal Motor Speed (NSP) | rpm | Read and write | |||
| Max Frequency (TFR) | Hz | Read and write | |||
| Autotuning (TUN) | Read and write | ||||
| Rotation Tune Enable (TUNR) | Read and write | ||||
| First Id Min Current Level In Rotation (IDL1) | % | Read and write | |||
| First Id Max Current Level In Rotation (IDH1) | % | Read and write | |||
| Second Id Min Current Level In Rotation (IDL2) | % | Read and write | |||
| Second Id Max Current Level In Rotation (IDH2) | % | Read and write | |||
| Rotation Tune Type (EFAP) | Read and write | ||||
| Number Of Autotuning Sequence Repetitions (TNBR) | Read and write | ||||
| Tangential Main Inductance (L0A) | Read and write | ||||
| Flux Saturation Curve Coefficient A (ALFA) | % | Read and write | |||
| Flux Saturation Curve Coefficient B (BET0) | % | Read and write | |||
| Automatic Autotune (AUT) | Read and write | ||||
| Autotuning Status (TUS) | Read | ||||
| Rotation Tune Status (TURS) | Read | ||||
| Rotation Tune Status PMSM (TRS2) | Read | ||||
| Rotation Tune Status SynRm (TRS3) | Read | ||||
| Motor Control Type (CTT) | Read and write | ||||
| Volt Point 1 On 5pt V/F (U1) | V | Read and write | |||
| Freq Point 1on 5pt V/F (F1) | Hz | Read and write | |||
| Volt Point 2 On 5pt V/F (U2) | V | Read and write | |||
| Freq Point 2 On 5pt V/F (F2) | Hz | Read and write | |||
| Volt Point 3 On 5pt V/F (U3) | V | Read and write | |||
| Freq Point 3 On 5pt V/F (F3) | Hz | Read and write | |||
| Volt Point 4 On 5pt V/F (U4) | V | Read and write | |||
| Freq Point 4 On 5pt V/F (F4) | Hz | Read and write | |||
| Volt Point 5 On 5pt V/F (U5) | V | Read and write | |||
| Freq Point 5 On 5pt V/F (F5) | Hz | Read and write | |||
| Sync Motor Nominal Current (NCRS) | Read and write | ||||
| Nominal Synchronous Motor Speed (NSPS) | rpm | Read and write | |||
| Pole Pairs Number (Sync) (PPNS) | Read and write | ||||
| Nominal Motor Torque (TQS) | Read and write | ||||
| Sync. EMF Constant (PHS) | Read and write | ||||
| Sync Motor D Inductance (LDS) | Read and write | ||||
| Sync Motor Q Inductance (LQS) | Read and write | ||||
| Calculated SyncMotor Stator R (RSAS) | Read and write | ||||
| IR Compensation (UFR) | % | Read and write | |||
| Slip Compensation (SLP) | % | Read and write | |||
| Number Of Pairs Of Poles Calculated (PPN) | Read | ||||
| Frequency Loop Gain (FLG) | % | Read and write | |||
| Frequency Loop Stability (STA) | % | Read and write | |||
| AsyncMotor Stator Resistance (RSA) | Read and write | ||||
| Magnetizing Current (IDA) | Read and write | ||||
| AsyncMotor Leakage Inductance (LFA) | Read and write | ||||
| Rotor Time Constant (TRA) | Read and write | ||||
| Synchronous Motor Nominal Freq (FRSS) | Hz | Read | |||
| Switching Frequency (SFR) | Read and write | ||||
| Current Limitation (CLI) | Read and write | ||||
| Switching Frequency Type (SFT) | Read and write | ||||
| Motor Noise Reduction (NRD) | Read and write | ||||
| Boost Activation (BOA) | Read and write | ||||
| Motor Surge Limitation (SVL) | Read and write | ||||
| Attenuation Time (SOP) | Read and write | ||||
| Braking Level (VBR) | V | Read and write | |||
| Braking Resistor Monitoring (BRO) | Read and write | ||||
| Braking Resistor Power (BRP) | kW | Read and write | |||
| Braking Resistor Value (BRV) | Ω | Read and write | |||
| Braking Resistor Time Constant (BRTC) | s | Read and write | |||
| Load Sharing (LBA) | Read and write | ||||
| Load Correction (LBC) | Hz | Read and write | |||
| Correction Min Speed (LBC1) | Hz | Read and write | |||
| Correction Max Speed (LBC2) | Hz | Read and write | |||
| Torque Offset (LBC3) | % | Read and write | |||
| Sharing Filter (LBF) | ms | Read and write | |||
| Fan Mode (FFM) | Read and write | ||||
| 2/3-Wire Control (TCC) | Read and write | ||||
| Type Of 2-Wire Control (TCT) | Read and write | ||||
| Reverse Assignment (RRS) | Read and write | ||||
| Reference Frequency Template Selection (BSP) | Read and write | ||||
| Configuration Of AI1 (AI1T) | Read and write | ||||
| AI1 Voltage Scaling Parameter Of 0% (UIL1) | V | Read and write | |||
| AI1 Voltage Scaling Parameter Of 100% (UIH1) | V | Read and write | |||
| AI1 Filter (AI1F) | s | Read and write | |||
| AI1 Intermediate Point X (AI1E) | % | Read and write | |||
| AI1 Intermediate Point Y (AI1S) | % | Read and write | |||
| Configuration Of AI2 (AI2T) | Read and write | ||||
| AI2 Voltage Scaling Parameter Of 0% (UIL2) | V | Read and write | |||
| AI2 Voltage Scaling Parameter Of 100% (UIH2) | V | Read and write | |||
| AI2 Filter (AI2F) | s | Read and write | |||
| AI2 Intermediate Point X (AI2E) | % | Read and write | |||
| AI2 Intermediate Point Y (AI2S) | % | Read and write | |||
| Configuration Of AI3 (AI3T) | Read and write | ||||
| AI3 Current Scaling Parameter Of 0% (CRL3) | mA | Read and write | |||
| AI3 Current Scaling Parameter Of 100% (CRH3) | mA | Read and write | |||
| AI3 Filter (AI3F) | s | Read and write | |||
| AI3 Intermediate Point X (AI3E) | % | Read and write | |||
| AI3 Intermediate Point Y (AI3S) | % | Read and write | |||
| AQ1 Assignment (AO1) | Read and write | ||||
| AQ1 Type (AO1T) | Read and write | ||||
| AQ1 Min Output Value (AOL1) | mA | Read and write | |||
| AQ1 Max Output Value (AOH1) | mA | Read and write | |||
| AQ1 Minimum Output (UOL1) | V | Read and write | |||
| AQ1 Maximum Output (UOH1) | V | Read and write | |||
| Scaling AQ1 Min (ASL1) | % | Read and write | |||
| Scaling AQ1 Max (ASH1) | % | Read and write | |||
| AQ1 Filter (AO1F) | s | Read and write | |||
| Configuration Reference Frequency 1 (FR1) | Read and write | ||||
| Reverse Direction Disable (RIN) | Read and write | ||||
| Stop Key Enable (PST) | Read and write | ||||
| Control Mode Configuration (CHCF) | Read and write | ||||
| Command Switching (CCS) | Read and write | ||||
| Command Channel 1 Assign (CD1) | Read and write | ||||
| Command Channel 2 Assign (CD2) | Read and write | ||||
| Freq Switching Assignment (RFC) | Read and write | ||||
| Configuration Reference Frequency 2 (FR2) | Read and write | ||||
| Copy Ch.1-Ch.2 (COP) | Read and write | ||||
| F1 Key Assignment (FN1) | Read and write | ||||
| F2 Key Assignment (FN2) | Read and write | ||||
| F3 Key Assignment (FN3) | Read and write | ||||
| F4 Key Assignment (FN4) | Read and write | ||||
| HMI Local/Remote Command (BMP) | Read and write | ||||
| Select Switching (1 To 1B) (RCB) | Read and write | ||||
| Configuration Ref. 1B (FR1B) | Read and write | ||||
| Summing Input 2 (SA2) | Read and write | ||||
| Summing Input 3 (SA3) | Read and write | ||||
| Subtract Reference Frequency 2 (DA2) | Read and write | ||||
| Subtract Reference Frequency 3 (DA3) | Read and write | ||||
| Reference Frequency 2 Multiply (MA2) | Read and write | ||||
| Reference Frequency 3 Multiply (MA3) | Read and write | ||||
| Type Of Ramp (RPT) | Read and write | ||||
| Ramp Increment (INR) | Read and write | ||||
| Acceleration Ramp Time (ACC) | Read and write | ||||
| Deceleration Ramp Time (DEC) | Read and write | ||||
| Start ACC Ramp Rounding (TA1) | % | Read and write | |||
| End ACC Ramp Rounding (TA2) | % | Read and write | |||
| Start DEC Ramp Rounding (TA3) | % | Read and write | |||
| End DEC Ramp Rounding (TA4) | % | Read and write | |||
| Ramp 2 Frequency Threshold (FRT) | Hz | Read and write | |||
| Ramp Switching Assignment (RPS) | Read and write | ||||
| Acceleration 2 Ramp Time (AC2) | Read and write | ||||
| Deceleration 2 (DE2) | Read and write | ||||
| Decel Ramp Adaptation (BRA) | Read and write | ||||
| Braking Balance (BBA) | Read and write | ||||
| Type Of Stop (STT) | Read and write | ||||
| Freewheel Stop Threshold (FFT) | Hz | Read and write | |||
| Freewheel Stop (NST) | Read and write | ||||
| Fast Stop Assignment (FST) | Read and write | ||||
| Fast Stop Ramp Divider (DCF) | Read and write | ||||
| DC Injection Assignment (DCI) | Read and write | ||||
| DC Injection Level 1 (IDC) | Read and write | ||||
| DC Injection Time 1 (TDI) | s | Read and write | |||
| DC Injection Level 2 (IDC2) | Read and write | ||||
| DC Injection Time 2 (TDC) | s | Read and write | |||
| Automatic DC Injection (ADC) | Read and write | ||||
| Auto DC Injection Level 1 (SDC1) | Read and write | ||||
| Auto DC Injection Time 1 (TDC1) | s | Read and write | |||
| Auto DC Injection Level 2 (SDC2) | Read and write | ||||
| Auto DC Injection Time 2 (TDC2) | s | Read and write | |||
| Jog Assignment (JOG) | Read and write | ||||
| Jog Frequency (JGF) | Hz | Read and write | |||
| Jog Delay (JGT) | s | Read and write | |||
| 2 Preset Freq Assignment (PS2) | Read and write | ||||
| 4 Preset Freq Assignment (PS4) | Read and write | ||||
| 8 Preset Freq Assignment (PS8) | Read and write | ||||
| 16 Preset Freq Assignment (PS16) | Read and write | ||||
| Preset Speed 2 (SP2) | Hz | Read and write | |||
| Preset Speed 3 (SP3) | Hz | Read and write | |||
| Preset Speed 4 (SP4) | Hz | Read and write | |||
| Preset Speed 5 (SP5) | Hz | Read and write | |||
| Preset Speed 6 (SP6) | Hz | Read and write | |||
| Preset Speed 7 (SP7) | Hz | Read and write | |||
| Preset Speed 8 (SP8) | Hz | Read and write | |||
| Preset Speed 9 (SP9) | Hz | Read and write | |||
| Preset Speed 10 (SP10) | Hz | Read and write | |||
| Preset Speed 11 (SP11) | Hz | Read and write | |||
| Preset Speed 12 (SP12) | Hz | Read and write | |||
| Preset Speed 13 (SP13) | Hz | Read and write | |||
| Preset Speed 14 (SP14) | Hz | Read and write | |||
| Preset Speed 15 (SP15) | Hz | Read and write | |||
| Preset Speed 16 (SP16) | Hz | Read and write | |||
| + Speed Assignment (USP) | Read and write | ||||
| - Speed Assignment (DSP) | Read and write | ||||
| Reference Frequency Save (STR) | Read and write | ||||
| + Speed Assignment (USI) | Read and write | ||||
| - Speed Assignment (DSI) | Read and write | ||||
| Stop Forward Limit Assignment (LAF) | Read and write | ||||
| Stop Reverse Limit Assignment (LAR) | Read and write | ||||
| Stop Type On Limit Switch (LAS) | Read and write | ||||
| +/- Speed Limitation (SRP) | % | Read and write | |||
| Reference Frequency Memory Assignment (SPM) | Read and write | ||||
| Motor Fluxing Configure (FLU) | Read and write | ||||
| Fluxing Input Assignment (FLI) | Read and write | ||||
| Auto Angle Setting Type (AST) | Read and write | ||||
| Angle Auto-Test (ASA) | Read and write | ||||
| Angle Test Assignment (ASL) | Read and write | ||||
| Angle Setting Activation Mode (ATA) | Read and write | ||||
| Activation Of HF Injection (HFI) | Read and write | ||||
| Bandwidth Of The HF PLL (SPB) | % | Read and write | |||
| Current Level Of The HF Alignment (ILR) | % | Read and write | |||
| Boost Level For IPMA Alignment (SIR) | % | Read and write | |||
| Maximum Current Of PSI Alignment (MCR) | % | Read and write | |||
| Angle Position Error Compensation (PEC) | % | Read and write | |||
| Brake Assignment (BLC) | Read and write | ||||
| Motion Type Selection (BST) | Read and write | ||||
| Brake Contact Input (BCI) | Read and write | ||||
| Brake Release Pulse (BIP) | Read and write | ||||
| Brake Release Current (IBR) | Read and write | ||||
| Rev. Brake Release Curr. (IRD) | Read and write | ||||
| Brake Release Time (BRT) | s | Read and write | |||
| Brake Release Frequency (BIR) | Hz | Read and write | |||
| Brake Engage Frequency (BEN) | Hz | Read and write | |||
| Brake Engage Delay (TBE) | s | Read and write | |||
| Brake Engage Time (BET) | s | Read and write | |||
| Brake Engage At Reversal (BED) | Read and write | ||||
| Jump At Reversal (JDC) | Hz | Read and write | |||
| Brake Engage At 0 Speed (BECD) | s | Read and write | |||
| Time To Restart (TTR) | s | Read and write | |||
| Brake Feedback Filter (FBCI) | ms | Read and write | |||
| Brake Hidden (BRH) | Read and write | ||||
| BRH_b4 Frequency Threshold Detection (BFTD) | Hz | Read and write | |||
| Load Maintain Time (MDFT) | min | Read and write | |||
| Current Ramp Time (BRR) | s | Read and write | |||
| High Speed Hoisting (HSO) | Read and write | ||||
| Motor Speed Coefficient (COF) | % | Read and write | |||
| Generator Speed Coefficient (COR) | % | Read and write | |||
| Load Measuring Time (TOS) | s | Read and write | |||
| Measurement Speed (OSP) | Hz | Read and write | |||
| High Speed I Limit (CLO) | Read and write | ||||
| Current Limit. Frequency (SCL) | Hz | Read and write | |||
| Rope Slack Torque Level (RSTL) | % | Read and write | |||
| Rope Slack Configuration (RSD) | Read and write | ||||
| PID Controller Feedback (PIF) | Read and write | ||||
| Minimum PID Feedback (PIF1) | Read and write | ||||
| Maximum PID Feedback (PIF2) | Read and write | ||||
| Minimum PID Process (PIP1) | Read and write | ||||
| Maximum PID Process (PIP2) | Read and write | ||||
| Internal PID Reference (PII) | Read and write | ||||
| Internal PID Reference (RPI) | Read and write | ||||
| PID Proportional Gain (RPG) | Read and write | ||||
| PID Controller Integral Gain (RIG) | Read and write | ||||
| PID Derivative Gain (RDG) | Read and write | ||||
| PID Ramp (PRP) | s | Read and write | |||
| PID Inversion (PIC) | Read and write | ||||
| PID Controller Min. Output (POL) | Hz | Read and write | |||
| PID Controller Max. Output (POH) | Hz | Read and write | |||
| Minimum Feedback Level Warning (PAL) | Read and write | ||||
| Maximum Feedback Level Warning (PAH) | Read and write | ||||
| PID Error Warning (PER) | Read and write | ||||
| PID Integral Disabled (PIS) | Read and write | ||||
| Predictive Speed Reference (FPI) | Read and write | ||||
| PID Speed Input % Ref (PSR) | % | Read and write | |||
| Auto/Manual Select Input (PAU) | Read and write | ||||
| Manual PID Reference (PIM) | Read and write | ||||
| Low Speed Timeout (TLS) | s | Read and write | |||
| 2 PID Preset Assignment (PR2) | Read and write | ||||
| 4 PID Preset Assignment (PR4) | Read and write | ||||
| 2nd PID Preset Reference (RP2) | Read and write | ||||
| 3rd PID Preset Reference (RP3) | Read and write | ||||
| 4th PID Preset Reference (RP4) | Read and write | ||||
| Torque Limit. Activation (TLA) | Read and write | ||||
| Torque Increment (INTP) | Read and write | ||||
| Motoring Torque Limit (TLIM) | Read and write | ||||
| Generator Torque Limit (TLIG) | Read and write | ||||
| Reference Torque Assignment (TAA) | Read and write | ||||
| Torque Analog Limit. Activ (TLC) | Read and write | ||||
| Torque/Speed Switching Control Mode (TSS) | Read and write | ||||
| Channel For Torque Reference (TR1) | Read and write | ||||
| Torque Reference Sign Switching (TSD) | Read and write | ||||
| Torque Regulation Negative Deadband (DBN) | Hz | Read and write | |||
| Torque Regulation Positive Deadband (DBP) | Hz | Read and write | |||
| Torque Ratio (TRT) | % | Read and write | |||
| Torque Ramp Time (TRP) | s | Read and write | |||
| Torque Control Stop Type (TST) | Read and write | ||||
| Response To Torque Control Error (TOB) | Read and write | ||||
| Torque Control Time Out (RTO) | s | Read and write | |||
| Spin Time (SPT) | s | Read and write | |||
| Torque Ratio Assignment (TQR) | Read and write | ||||
| Torque Offset Assignment (TQO) | Read and write | ||||
| Torque Reference Assignment (TRI) | Read and write | ||||
| Torque Reference 2 Channel (TR2) | Read and write | ||||
| Current Limitation 2 (LC2) | Read and write | ||||
| Current Limitation 2 Value (CL2) | Read and write | ||||
| Reference Torque Switch Assignment (TASU) | Read and write | ||||
| Reference Torque 2 Assignment (TAA2) | Read and write | ||||
| Mains Contactor Control (LLC) | Read and write | ||||
| Device Lock Assignment (LES) | Read and write | ||||
| Mains V. Time Out (LCT) | s | Read and write | |||
| Fwd Stop Limit Input Assig (SAF) | Read and write | ||||
| RV Stop Limit Input Assign (SAR) | Read and write | ||||
| Forward Slowdown Limit (DAF) | Read and write | ||||
| Reverse Slowdown Limit (DAR) | Read and write | ||||
| Disable Limit Switch (CLS) | Read and write | ||||
| Stop Type (PAS) | Read and write | ||||
| Deceleration Type (DSF) | Read and write | ||||
| Stop Distance (STD) | m | Read and write | |||
| Rated Linear Speed (NLS) | m/s | Read and write | |||
| Distance Stop Corrector (SFD) | % | Read and write | |||
| Multimotors Selection (CHM) | Read and write | ||||
| 2 Configurations Assignt. (CNF1) | Read and write | ||||
| 3 Configurations Assignt. (CNF2) | Read and write | ||||
| Autotuning Input Assignment (TUL) | Read and write | ||||
| Fault Reset Input Assignment (RSF) | Read and write | ||||
| Product Restart (RP) | Read and write | ||||
| Product Restart Assignment (RPA) | Read and write | ||||
| Automatic Fault Reset (ATR) | Read and write | ||||
| Fault Reset Time (TAR) | Read and write | ||||
| Catch On Fly (FLR) | Read and write | ||||
| Motor Thermal Monitoring Mode (THT) | Read and write | ||||
| Motor Thermal Threshold (TTD) | % | Read and write | |||
| Motor 2 Thermal Threshold (TTD2) | % | Read and write | |||
| Motor 3 Thermal Threshold (TTD3) | % | Read and write | |||
| Motor 4 Thermal Threshold (TTD4) | % | Read and write | |||
| Motor Overtemp Error Response (OLL) | Read and write | ||||
| Output Phase Loss Assignment (OPL) | Read and write | ||||
| Output Phase Loss Delay (ODT) | s | Read and write | |||
| Input Phase Loss Assignment (IPL) | Read and write | ||||
| Drive Overtemp Error Response (OHL) | Read and write | ||||
| Device Thermal State Warning (THA) | % | Read and write | |||
| External Error Assignment (ETF) | Read and write | ||||
| Device Response To External Error (EPL) | Read and write | ||||
| Response To Undervoltage (USB) | Read and write | ||||
| Evacuation Mains Voltage (URES) | Read and write | ||||
| Undervoltage Level (USL) | V | Read and write | |||
| Undervoltage Timeout (UST) | s | Read and write | |||
| Stop Type On Power Loss (STP) | Read and write | ||||
| Undervolt. Restart Time (TSM) | s | Read and write | |||
| Under V Prevention Level (UPL) | V | Read and write | |||
| Load Slip Detection (SDD) | Read and write | ||||
| Maximum Stop Time (STM) | s | Read and write | |||
| DC Bus Charge Assignment (DCO) | Read and write | ||||
| DC Bus Charge Opt. Time (DCT) | s | Read and write | |||
| DC Bus Maintain Time (TBS) | s | Read and write | |||
| Output Short Circuit Test (STRT) | Read and write | ||||
| Catch On Fly Mode (COFM) | Read and write | ||||
| Response To 4-20mA Loss On AI3 (LFL3) | Read and write | ||||
| Disable Error Detection (INH) | Read and write | ||||
| Response To Fieldbus Module Communication Interruption (CLL) | Read and write | ||||
| Response To CANopen Error (COL) | Read and write | ||||
| Response To Modbus Interruption (SLL) | Read and write | ||||
| Stop Type - Torque/I Limit (SSB) | Read and write | ||||
| Torque/I Limit. Timeout (STO) | ms | Read and write | |||
| Response To Autotuning Error (TNL) | Read and write | ||||
| Pairing Password (PPI) | Read and write | ||||
| Fall Back Speed (LFF) | Hz | Read and write | |||
| Frequency Meter (FQF) | Read and write | ||||
| Pulse Scaling Divisor (FQC) | Read and write | ||||
| Overspd. Pulse Threshold (FQA) | Hz | Read and write | |||
| Pulse Overspeed Delay (TDS) | s | Read and write | |||
| Level Freq. Pulse Ctrl (FDT) | Hz | Read and write | |||
| Pulse Threshold Wo Run (FQT) | Hz | Read and write | |||
| Dynamic Load Time (TLD) | s | Read and write | |||
| Dynamic Load Threshold (DLD) | % | Read and write | |||
| Dynamic Load Mgt. (DLB) | Read and write | ||||
| Scan Output 1 Address (NCA1) | Read and write | ||||
| Scan Output 2 Address (NCA2) | Read and write | ||||
| Scan Output 3 Address (NCA3) | Read and write | ||||
| Scan Output 4 Address (NCA4) | Read and write | ||||
| Scan Output 5 Address (NCA5) | Read and write | ||||
| Scan Output 6 Address (NCA6) | Read and write | ||||
| Scan Output 7 Address (NCA7) | Read and write | ||||
| Scan Output 8 Address (NCA8) | Read and write | ||||
| Scan Input 1 Address (NMA1) | Read and write | ||||
| Scan Input 2 Address (NMA2) | Read and write | ||||
| Scan Input 3 Address (NMA3) | Read and write | ||||
| Scan Input 4 Address (NMA4) | Read and write | ||||
| Scan Input 5 Address (NMA5) | Read and write | ||||
| Scan Input 6 Address (NMA6) | Read and write | ||||
| Scan Input 7 Address (NMA7) | Read and write | ||||
| Scan Input 8 Address (NMA8) | Read and write | ||||
| Scan Input 1 Address (OMA1) | Read and write | ||||
| Scan Input 2 Address (OMA2) | Read and write | ||||
| Scan Input 3 Address (OMA3) | Read and write | ||||
| Scan Input 4 Address (OMA4) | Read and write | ||||
| Scan Input 5 Address (OMA5) | Read and write | ||||
| Scan Input 6 Address (OMA6) | Read and write | ||||
| Scan Output 1 Address (OCA1) | Read and write | ||||
| Scan Output 2 Address (OCA2) | Read and write | ||||
| Scan Output 3 Address (OCA3) | Read and write | ||||
| Scan Output 4 Address (OCA4) | Read and write | ||||
| Scan Output 5 Address (OCA5) | Read and write | ||||
| Scan Output 6 Address (OCA6) | Read and write | ||||
| Device Modbus Address (ADD) | Read and write | ||||
| Mdb Add Comm. Module (AMOC) | Read and write | ||||
| Modbus Baud Rate (TBR) | Read and write | ||||
| Modbus Format (TFO) | Read and write | ||||
| Modbus Timeout (TTO) | s | Read and write | |||
| Device CANopen Address (ADCO) | Read and write | ||||
| CANopen Baudrate (BDCO) | Read and write | ||||
| CANopen Error (ERCO) | Read | ||||
| Forced Local Assignment (FLO) | Read and write | ||||
| Forced Local Channel Assignment (FLOC) | Read and write | ||||
| Time-Out Forc. Local (FLOT) | s | Read and write | |||
| Device Address (ADRC) | Read and write | ||||
| PPO Profile Used (PRFL) | Read and write | ||||
| Configured Assembly (CIOA) | Read and write | ||||
| Comm. Option Baudrate (BDR) | Read and write | ||||
| Data Rate Used (BDRU) | Read and write | ||||
| Rate And Duplex Setting (RDS) | Read and write | ||||
| Actual Rate And Duplex (ARD) | Read | ||||
| DI1 Delay (L1D) | ms | Read and write | |||
| R1 Assignment (R1) | Read and write | ||||
| R2 Assignment (R2) | Read and write | ||||
| DI2 Delay (L2D) | ms | Read and write | |||
| R1 Delay Time (R1D) | ms | Read and write | |||
| R2 Delay Time (R2D) | ms | Read and write | |||
| DI3 Delay (L3D) | ms | Read and write | |||
| R1 Active Level (R1S) | Read and write | ||||
| R2 Active Level (R2S) | Read and write | ||||
| DI4 Delay (L4D) | ms | Read and write | |||
| R1 Holding Time (R1H) | ms | Read and write | |||
| R2 Holding Time (R2H) | ms | Read and write | |||
| DI5 Delay (L5D) | ms | Read and write | |||
| DI6 Delay (L6D) | ms | Read and write | |||
| DI7 Delay (L7D) | ms | Read and write | |||
| DI8 Delay (L8D) | ms | Read and write | |||
| DQ1 Assignment (DO1) | Read and write | ||||
| DQ2 Assignment (DO2) | Read and write | ||||
| DQ1 Delay Time (DO1D) | ms | Read and write | |||
| DQ1 Holding Time (DO1H) | ms | Read and write | |||
| DQ1 Active Level (DO1S) | Read and write | ||||
| FRH High Resolution (FRHT) | Read | ||||
| LCR Without Filter (SLCR) | Read | ||||
| RFR Without Filter (SRFR) | Hz | Read | |||
| Measured Output Freq. (MMF) | Hz | Read | |||
| Motor Torque (% Of Cn Motor In Q12) Without Filter (SOTR) | Read | ||||
| ULN Without Filter (SULN) | V | Read | |||
| OPR Without Filter (SOPR) | % | Read | |||
| Number Of Pulses (PGI) | Read and write | ||||
| AB Encoder Type Configuration (ENS) | Read and write | ||||
| Encoder Usage (ENU) | Read and write | ||||
| Encoder Check (ENC) | Read and write | ||||
| Encoder Coupling Monitoring (ECC) | Read and write | ||||
| Encoder Check Time (ECT) | s | Read and write | |||
| Resolver Poles Nbr (RPPN) | Read and write | ||||
| Encoder Type (UECP) | Read and write | ||||
| Encoder Supply Voltage (UECV) | Read and write | ||||
| Inversion Of Encoder Rotation Direction (ENRI) | Read and write | ||||
| Encoder Feeback Filter Activation (FFA) | Read and write | ||||
| Encoder Feedback Filter Value (FFR) | ms | Read and write | |||
| Underload Detection Delay (ULT) | s | Read and write | |||
| Hysteresis Frequency (SRB) | Hz | Read and write | |||
| Response To Underload Error (UDL) | Read and write | ||||
| Unld. Freq.Thr. Detection (RMUD) | Hz | Read and write | |||
| Unld.Thr. At O Speed (LUL) | % | Read and write | |||
| Unld.Thr. At Nom. Speed (LUN) | % | Read and write | |||
| Overload Detection Delay (TOL) | s | Read and write | |||
| Response To Overload Error (ODL) | Read and write | ||||
| PID Acceleration Time (ACCP) | Read and write | ||||
| AI4 Intermediate Point X (AI4E) | % | Read and write | |||
| AI4 Filter (AI4F) | s | Read and write | |||
| AI4 Intermediate Point Y (AI4S) | % | Read and write | |||
| Configuration Of AI4 (AI4T) | Read and write | ||||
| AI5 Intermediate Point X (AI5E) | % | Read and write | |||
| AI5 Filter (AI5F) | s | Read and write | |||
| AI5 Delinearization Output Level (AI5S) | % | Read and write | |||
| Configuration Of AI5 (AI5T) | Read and write | ||||
| Channel Assignment For Virtual Analog Input AIV1 (AIC1) | Read and write | ||||
| AQ2 Assignment (AO2) | Read and write | ||||
| AQ2 Filter (AO2F) | s | Read and write | |||
| AQ2 Type (AO2T) | Read and write | ||||
| AQ2 Max Output Value (AOH2) | mA | Read and write | |||
| AQ2 Min Output Value (AOL2) | mA | Read and write | |||
| Scaling AQ2 Max (ASH2) | % | Read and write | |||
| Scaling AQ2 Min (ASL2) | % | Read and write | |||
| Customer Warning Clearing (CAR) | Read and write | ||||
| Configuration Of Customer Warning 1 (CCA1) | Read and write | ||||
| Configuration Of Customer Warning 2 (CCA2) | Read and write | ||||
| Configuration Of Customer Warning 3 (CCA3) | Read and write | ||||
| Configuration Of Customer Warning 4 (CCA4) | Read and write | ||||
| Configuration Of Customer Warning 5 (CCA5) | Read and write | ||||
| Configuration Counter Limit 1 (CCL1) | s | Read and write | |||
| Configuration Counter Limit 2 (CCL2) | s | Read and write | |||
| Configuration Counter Limit 3 (CCL3) | s | Read and write | |||
| Configuration Counter Limit 4 (CCL4) | s | Read and write | |||
| Configuration Counter Limit 5 (CCL5) | s | Read and write | |||
| Configuration Counter Source 1 (CCS1) | Read and write | ||||
| Configuration Counter Source 2 (CCS2) | Read and write | ||||
| Configuration Counter Source 3 (CCS3) | Read and write | ||||
| Configuration Counter Source 4 (CCS4) | Read and write | ||||
| Configuration Counter Source 5 (CCS5) | Read and write | ||||
| Date Time Warning 1 (CDT1) | Read and write | ||||
| Date Time Warning 2 (CDT2) | Read and write | ||||
| Date Time Warning 3 (CDT3) | Read and write | ||||
| Date Time Warning 4 (CDT4) | Read and write | ||||
| Date Time Warning 5 (CDT5) | Read and write | ||||
| AI1 Current Scaling Parameter Of 100% (CRH1) | mA | Read and write | |||
| AI4 Current Scaling Parameter Of 100% (CRH4) | mA | Read and write | |||
| AI5 Current Scaling Parameter Of 100% (CRH5) | mA | Read and write | |||
| AI1 Current Scaling Parameter Of 0% (CRL1) | mA | Read and write | |||
| AI4 Current Scaling Parameter Of 0% (CRL4) | mA | Read and write | |||
| AI5 Current Scaling Parameter Of 0% (CRL5) | mA | Read and write | |||
| Low Current Threshold (CTDL) | Read and write | ||||
| DQ11 Activation Delay (D11D) | ms | Read and write | |||
| DQ11 Holding Delay (D11H) | ms | Read and write | |||
| DQ11 Status (Output Active Level) (D11S) | Read and write | ||||
| DQ12 Activation Delay (D12D) | ms | Read and write | |||
| DQ12 Holding Delay (D12H) | ms | Read and write | |||
| DQ12 Status (Output Active Level) (D12S) | Read and write | ||||
| DO11 Assignment (DO11) | Read and write | ||||
| DO12 Assignment (DO12) | Read and write | ||||
| Dual Rating State (DRT) | Read and write | ||||
| CO2 Ratio (ECO2) | Read and write | ||||
| KWh Cost (ECST) | Read and write | ||||
| Ethernet Error Response (ETHL) | Read and write | ||||
| 2 Frequency Threshold (F2DL) | Hz | Read and write | |||
| Low Freq. Threshold (FTDL) | Hz | Read and write | |||
| Ovld Time Before Restart (FTO) | min | Read and write | |||
| Unld Time Before Restart (FTU) | min | Read and write | |||
| Ground Fault Activation (GRFL) | % | Read and write | |||
| NCR Current Scaling (INRC) | Read | ||||
| LFA Inductance Scaling (INRL) | Read | ||||
| NPR Power Scaling (INRP) | Read | ||||
| RSA Resistance Scaling (INRR) | Read | ||||
| Torque Scaling (INRT) | Read and write | ||||
| TRA Time Scaling (INTI) | Read | ||||
| DI11 Delay (L11D) | ms | Read and write | |||
| DI12 Delay (L12D) | ms | Read and write | |||
| DI13 Delay (L13D) | ms | Read and write | |||
| DI14 Delay (L14D) | ms | Read and write | |||
| DI15 Delay (L15D) | ms | Read and write | |||
| DI16 Delay (L16D) | ms | Read and write | |||
| Log Distribution Data 1 (LDD1) | Read and write | ||||
| Log Distribution Data 2 (LDD2) | Read and write | ||||
| Log Distribution Data 3 (LDD3) | Read and write | ||||
| Log Distribution Data 4 (LDD4) | Read and write | ||||
| Logging Distribution State (LDEN) | Read and write | ||||
| Distribution Data Max Value 1 (LDM1) | Read and write | ||||
| Distribution Data Max Value 2 (LDM2) | Read and write | ||||
| Distribution Data Max Value 3 (LDM3) | Read and write | ||||
| Distribution Data Max Value 4 (LDM4) | Read and write | ||||
| Logging Distribution Sample Time (LDST) | Read and write | ||||
| Response To 4-20mA Loss On AI1 (LFL1) | Read and write | ||||
| Response To 4-20mA Loss On AI4 (LFL4) | Read and write | ||||
| Response To 4-20mA Loss On AI5 (LFL5) | Read and write | ||||
| Current Overload Threshold (LOC) | % | Read and write | |||
| Number Of Motor Starts (NSM) | Read and write | ||||
| Sinus Filter Activation (OFI) | Read and write | ||||
| Over-Consumption Threshold (PCAH) | % | Read and write | |||
| Under-Consumption Threshold (PCAL) | % | Read and write | |||
| Over/Under-Consumption Time Delay (PCAT) | min | Read and write | |||
| DI7 Frequency Filter (PFI7) | ms | Read and write | |||
| DI8 Frequency Filter (PFI8) | ms | Read and write | |||
| Output Phase Rotation (PHR) | Read and write | ||||
| DI7 PulseInput High Frequency (PIH7) | Read and write | ||||
| DI8 PulseInput High Frequency (PIH8) | Read and write | ||||
| DI7 PulseInput Low Frequency (PIL7) | Hz | Read and write | |||
| DI8 PulseInput Low Frequency (PIL8) | Hz | Read and write | |||
| R3 Assignment (R3) | Read and write | ||||
| R3 Delay Time (R3D) | ms | Read and write | |||
| R3 Holding Time (R3H) | ms | Read and write | |||
| R3 Active Level (R3S) | Read and write | ||||
| R4 Assignment (R4) | Read and write | ||||
| R4 Delay Time (R4D) | ms | Read and write | |||
| R4 Holding Time (R4H) | ms | Read and write | |||
| R4 Active Level (R4S) | Read and write | ||||
| R5 Assignment (R5) | Read and write | ||||
| R5 Delay Time (R5D) | ms | Read and write | |||
| R5 Holding Time (R5H) | ms | Read and write | |||
| R5 Active Level (R5S) | Read and write | ||||
| R6 Assignment (R6) | Read and write | ||||
| R6 Activation Delay Time (R6D) | ms | Read and write | |||
| R6 Holding Delay Time (R6H) | ms | Read and write | |||
| R6 Active Level (R6S) | Read and write | ||||
| Reference High Threshold (RTD) | Hz | Read and write | |||
| Reference Low Threshold (RTDL) | Hz | Read and write | |||
| PID Start Ref Frequency (SFS) | Hz | Read and write | |||
| Sleep Offset Threshold (SLE) | Hz | Read and write | |||
| Motor Stall Max Time (STP1) | s | Read and write | |||
| Stall Monitoring Current Level (STP2) | % | Read and write | |||
| Stall Monitoring Frequency Level (STP3) | Hz | Read and write | |||
| Stall Monitoring Activation (STPC) | Read and write | ||||
| Modbus 2 Baud Rate (TBR2) | Read and write | ||||
| Modbus 2 Format (TFO2) | Read and write | ||||
| Thermal Warning Level For AI1 (TH1A) | Read and write | ||||
| Response To Thermal Error For AI1 (TH1B) | Read and write | ||||
| Thermal Warning Level For AI3 (TH3A) | Read and write | ||||
| Thermal Error Level For AI1 (TH1F) | Read and write | ||||
| Response To Thermal Error For AI3 (TH3B) | Read and write | ||||
| Activation Of The Thermal Monitoring On AI1 (TH1S) | Read and write | ||||
| Thermal Error Level For AI3 (TH3F) | Read and write | ||||
| Activation Of The Thermal Monitoring On AI3 (TH3S) | Read and write | ||||
| Thermal Warning Level For AI4 (TH4A) | Read and write | ||||
| Response To Thermal Error For AI4 (TH4B) | Read and write | ||||
| Thermal Error Level For AI4 (TH4F) | Read and write | ||||
| Activation Of The Thermal Monitoring On AI4 (TH4S) | Read and write | ||||
| Thermal Warning Level For AI5 (TH5A) | Read and write | ||||
| Response To Thermal Error For AI5 (TH5B) | Read and write | ||||
| Thermal Error Level For AI5 (TH5F) | Read and write | ||||
| Activation Of The Thermal Monitoring On AI5 (TH5S) | Read and write | ||||
| Type Of Control (TOCT) | Read and write | ||||
| Pulse Without Run Delay (TQB) | s | Read and write | |||
| Ethernet Embedded : Time-Out (TTOB) | s | Read and write | |||
| AI3 Voltage Scaling Parameter Of 100% (UIH3) | V | Read and write | |||
| AI4 Voltage Scaling Parameter Of 100% (UIH4) | V | Read and write | |||
| AI5 Voltage Scaling Parameter Of 100% (UIH5) | V | Read and write | |||
| AI3 Voltage Scaling Parameter Of 0% (UIL3) | V | Read and write | |||
| AI4 Voltage Scaling Parameter Of 0% (UIL4) | V | Read and write | |||
| AI5 Voltage Scaling Parameter Of 0% (UIL5) | V | Read and write | |||
| AQ2 Maximum Output (UOH2) | V | Read and write | |||
| AQ2 Minimum Output (UOL2) | V | Read and write | |||
| Catch On Fly Sensitivity (VCB) | V | Read and write | |||
| Reference Power Without Drive (PREF) | Read and write | ||||
| High Torque (HTQ) | % | Read and write | |||
| Low Torque (LTQ) | % | Read and write | |||
| Braking Resistor Connected (BRC) | Read and write | ||||
| PTO Maximum Output Frequency (PTOH) | Read and write | ||||
| PTO Assignment (PTO) | Read and write | ||||
| SSI Code Type (SSCD) | Read and write | ||||
| SSI Parity (SSCP) | Read and write | ||||
| SSI Frame Size (SSFS) | Read and write | ||||
| Number Of Revolutions (ENMR) | Read and write | ||||
| Turn Bit Resolution (ENTR) | Read and write | ||||
| Resolver Excitation Frequency (REFQ) | Read and write | ||||
| Clock Frequency (ENSP) | Read and write | ||||
| Reset Position Assignment (RPOS) | Read and write | ||||
| AB Encoder Maximum Frequency (ABMF) | Read and write | ||||
| Autotuning Type (TUNT) | Read and write | ||||
| Memo Stop (MSTP) | Read and write | ||||
| Priority Restart (PRST) | Read and write | ||||
| Backlash Mode (BQM) | Read and write | ||||
| Response To Backlash Error (BQFB) | Read and write | ||||
| Backlash Reference Frequency (BQSL) | Hz | Read and write | |||
| Backlash Acceleration (BQA) | Read and write | ||||
| Backlash Torque Limitation Value (BQTL) | % | Read and write | |||
| Backlash Torque Limitation Monitoring Delay (BQT) | s | Read and write | |||
| Backlash Start Delay (BQST) | s | Read and write | |||
| Backlash Timeout (BQFD) | s | Read and write | |||
| Backlash Type (BQMM) | Read and write | ||||
| Backlash On Slave(S) Feedback (BQMC) | Read and write | ||||
| Backlash Time (BQMT) | s | Read and write | |||
| PTI Mode (PTIM) | Read and write | ||||
| PTI Direction Inversion (PTII) | Read and write | ||||
| PTI Filter Time Inp (PTIS) | Read and write | ||||
| PTI Low Freq (PTIL) | Hz | Read and write | |||
| PTI High Frequency (PTIH) | Hz | Read and write | |||
| PTI Filter Time Analog (PTIT) | ms | Read and write | |||
| PTO Mode Selection (PTOM) | Read and write | ||||
| PTO Low Frequency (PTOB) | Hz | Read and write | |||
| PTO High Frequency (PTOU) | Hz | Read and write | |||
| Frequency Min Value (PEIL) | Read and write | ||||
| Frequency Max Value (PEFR) | Read and write | ||||
| M/S Device Selection (MSDN) | Read and write | ||||
| Application Selection (APPT) | Read and write | ||||
| Motor Parameter Choice (MPC) | Read and write | ||||
| Internal Currents Filter Time (CRFA) | ms | Read and write | |||
| Autotuning Usage (TUNU) | Read and write | ||||
| Level Of Current For Autotuning (TCR) | % | Read and write | |||
| Alignment Rotational Current Level (RCL) | % | Read and write | |||
| RCI Alignment With Transformer (RCIR) | Read and write | ||||
| RCI Maximum Output Frequency (RCSP) | Hz | Read and write | |||
| Encoder Thermal Sensor Type (THET) | Read and write | ||||
| Response To Thermal Error For Encoder (THEB) | Read and write | ||||
| Thermal Error Level For Encoder (THEF) | Read and write | ||||
| Thermal Warning Level For Encoder (THEA) | Read and write | ||||
| Boost (BOO) | % | Read and write | |||
| Boost On Deceleration (BOO2) | % | Read and write | |||
| Frequency Boost (FAB) | Hz | Read and write | |||
| External Feed Forward Assignment (TEFF) | Read and write | ||||
| Frequency Of The HF Injection Signal (FRI) | Hz | Read and write | |||
| M/S Communication Mode (MSCM) | Read and write | ||||
| Master Or Slave ID Selection (MSID) | Read and write | ||||
| Master Or Slave Selection (MSDT) | Read and write | ||||
| M/S Number Of Slaves (MSSN) | Read and write | ||||
| M/S Master Speed Reference Input Assignment (MSSI) | Read and write | ||||
| M/S Master Torque Reference Input Assignment (MSTI) | Read and write | ||||
| M/S Speed Reference Output Assignment (MSSO) | Read and write | ||||
| M/S Torque Reference Output Assignment (MSTO) | Read and write | ||||
| M/S Local Mode Assignment (MSDI) | Read and write | ||||
| MultiDrive Link Communication Timeout (MLTO) | s | Read and write | |||
| M/S Response To Communication Error (MSCB) | Read and write | ||||
| M/S Response To Device Error (MSDB) | Read and write | ||||
| M/S Device Error Delay (MSDD) | s | Read and write | |||
| M/S Mechanical Coupling Type (MSMC) | Read and write | ||||
| M/S Control Type (MSCT) | Read and write | ||||
| Speed Reference Direction (SSD) | Read and write | ||||
| Torque Reference Offset (TQOP) | % | Read and write | |||
| Torque Filter Activation (TRF) | Read and write | ||||
| Torque Filter Bandwidth (TRW) | Hz | Read and write | |||
| M/S Advanced Filter Activation (MSFE) | Read and write | ||||
| M/S Advanced Filter Frequency (MSFF) | Hz | Read and write | |||
| M/S Advanced Filter Bandwidth (MSFB) | % | Read and write | |||
| M/S Advanced Filter Depth (MSFD) | % | Read and write | |||
| M/S Advanced Filter Gain (MSFG) | % | Read and write | |||
| M/S Advanced Filter Coefficient (MSFC) | % | Read and write | |||
| M/S Load Balancing Torque Reference Selection (MSIB) | Read and write | ||||
| M/S Master Torque Reference Entry In Control Chain (MSIT) | Read and write | ||||
| M/S Output Torque Reference Selection (MSOT) | Read and write | ||||
| M/S Master Speed Reference Entry In Control Chain (MSIS) | Read and write | ||||
| M/S Output Speed Reference Selection (MSOS) | Read and write | ||||
| Maximum Power In Motor Mode (TPMM) | % | Read and write | |||
| Maximum Power In Generator Mode (TPMG) | % | Read and write | |||
| PTO Min Output Frequency (PTOL) | Read and write | ||||
| Resolver Transformation Ratio (TRES) | Read and write | ||||
| Sincos Lines Count (UELC) | Read and write | ||||
| Stop On Next Top Z Detection (TOST) | Read and write | ||||
| Drive Overload Monitoring Activation (TLOL) | Read and write | ||||
| Terminal Modbus: Word Order (TWO) | Read and write | ||||
| Terminal Modbus 2: Word Order (TWO2) | Read and write | ||||
| FDR Error Status (FDR1) | Read | ||||
| FDR Operating State (FDS1) | Read | ||||
| FDR Action (FDA1) | Read and write | ||||
| Enable FDR Function (FDV1) | Read and write | ||||
| Control Scope Assignment 1 (PSA1) | Read and write | ||||
| Control Scope Assignment 2 (PSA2) | Read and write | ||||
| Control Scope Assignment 3 (PSA3) | Read and write | ||||
| Control Scope Assignment 4 (PSA4) | Read and write | ||||
| Upload Rights (ULR) | Read and write | ||||
| Download Rights (DLR) | Read and write | ||||
| Drive Systems Pre-Settings Unlock (PSRT) | Read and write | ||||
| AIV1 Assignment (AV1A) | Read | ||||
| PTO Assignment (PTOE) | Read and write | ||||
| Modbus Reference Frequency (LFR1) | Read and write | ||||
| CANopen Reference Frequency (LFR2) | Read and write | ||||
| Communication Module Reference Frequency (LFR3) | Read and write | ||||
| Embedded Ethernet Reference Frequency (LFR5) | Read and write | ||||
| Extended Fault Reset Activation (HRFC) | Read and write | ||||
| Fieldbus Communication Loss Fallback Channel (AFFL) | Read and write | ||||
| AI Loss Inhibition (INLF) | Read and write | ||||
| Emb. Enc. Type (EECP) | Read and write | ||||
| Emb. Enc. Numb. Of Pulses (EPGI) | Read and write | ||||
| Emb. Enc. Sincos Lines Cnt (EELC) | Read and write | ||||
| Emb. Enc. Usage (EENU) | Read and write | ||||
| Emb. Enc. Rotation Inv. (EERI) | Read and write | ||||
| Emb. Enc. Supply Volt. (EECV) | Read and write | ||||
| Torque Filter Time (TQTF) | ms | Read and write | |||
| Field Weakening Correction Bandwidth (FWBW) | Hz | Read and write | |||
| Maximum Braking Current Level (BDCL) | % | Read and write | |||
| Slip Compensation In Generator Mode (SLPC) | Read and write | ||||
| Nominal Mechanical Power (NMP) | Read | ||||
| Nominal Motor Torque Scaling (TQNC) | Read and write | ||||
| Advanced Motor Control (AEMC) | Read and write | ||||
| Speed Measurement Feedback Performance (SMFP) | Read and write | ||||
| Speed Measurement Bandwidth (SMBW) | Hz | Read and write | |||
| Profidrive Profile - RFG Tolerance Parameter (PTR) | % | Read and write | |||
| Profidrive Profile - RFG Tmax Parameter (PTM) | Read and write | ||||
| Profinet ModbusTCP Word Order (TWOP) | Read and write | ||||
| IPar Service Activation (IPAV) | Read and write | ||||
| IPar Autosave Activation (IPAS) | Read and write | ||||
| IPAR Local Configuration (ICFG) | Read and write | ||||
| IPar Response To Detected Error (IPAF) | Read and write | ||||
| IPar Autosave Timer (IPAT) | Read and write | ||||
| IPar Service Status (IPAE) | Read and write | ||||
| IPAR Action (IPAA) | Read and write | ||||
| IPAR Action Status (IPAC) | Read | ||||
| IPAR Configuration Selection (IPAM) | Read and write | ||||
| PNU 1000 Behavior (PNU) | Read and write | ||||
| Embedded RSTP Configuration (ST0C) | Read and write | ||||
| RSTP Option Module Configuration (ST1C) | Read and write | ||||
| Receive PDO3-1 (RP31) | Read | ||||
| Receive PDO3-2 (RP32) | Read | ||||
| Receive PDO3-3 (RP33) | Read | ||||
| Receive PDO3-4 (RP34) | Read | ||||
| Transmit PDO3-1 (TP31) | Read | ||||
| Transmit PDO3-2 (TP32) | Read | ||||
| Transmit PDO3-3 (TP33) | Read | ||||
| Transmit PDO3-4 (TP34) | Read | ||||
| Number Of TX PDO (NBTP) | Read | ||||
| Number Of RX PDO (NBRP) | Read | ||||
| Configuration Of Virtual Analog Input AIV1 (AV1T) | Read and write | ||||
| EPF2 (External Error Detected By Fieldbus) Info (EPF2) | Read and write | ||||
| DC Injection Angle (TAFI) | ° | Read and write | |||
| Delay To Close O/P Cont. (DBS) | s | Read and write | |||
| Delay To Open Contactor (DAS) | s | Read and write | |||
| Output Contactor Fdbk (RCA) | Read and write | ||||
| Output Contactor Control Assignment (OCC) | Read and write | ||||
| Power Backup Input Assignment (RFT) | Read and write | ||||
| Power Backup Voltage (RSU) | V | Read and write | |||
| Power Backup Reference Frequency (RSP) | Hz | Read and write | |||
| Torque Filter Time (TPFV) | ms | Read and write | |||
| Motor Run Time (RTHH) | h | Read and write | |||
| Power-On Time (PTHH) | h | Read and write | |||
| Memo Slowdown (MSLO) | Read and write | ||||
| Brake Relay Feedback (BRI) | Read and write | ||||
| Brake Relay Feedback Filter (FBRI) | ms | Read and write | |||
| Id Current Magnetic Saturation Curve For SynRM Law (Point (ID1) | Read and write | ||||
| Id Current Magnetic Saturation Curve For SynRM Law (Point (ID2) | Read and write | ||||
| Id Current Magnetic Saturation Curve For SynRM Law (Point (ID3) | Read and write | ||||
| Id Current Magnetic Saturation Curve For SynRM Law (Point (ID4) | Read and write | ||||
| Id Current Magnetic Saturation Curve For SynRM Law (Point (ID5) | Read and write | ||||
| PHS Scaling (IPHS) | Read and write | ||||
| Ld Inductance For Magnetic Saturation Curve SynRM Law (Po (LD1) | Read and write | ||||
| Ld Inductance For Magnetic Saturation Curve SynRM Law (Po (LD2) | Read and write | ||||
| Ld Inductance For Magnetic Saturation Curve SynRM Law (Po (LD3) | Read and write | ||||
| Ld Inductance For Magnetic Saturation Curve SynRM Law (Po (LD4) | Read and write | ||||
| Ld Inductance For Magnetic Saturation Curve SynRM Law (Po (LD5) | Read and write | ||||
| Rotation Tune Reference Frequency (TLFR) | Hz | Read and write | |||
| Tune Period Interval (TPD) | h | Read and write | |||
| Speed Maintain'S Behavior (RLS) | Hz | Read and write | |||
| Enable Relay 1 Fallback (R1F) | Read and write | ||||
| Enable Relay 2 Fallback (R2F) | Read and write | ||||
| Enable Relay 3 Fallback (R3F) | Read and write | ||||
| Enable Relay 4 Fallback (R4F) | Read and write | ||||
| Enable Relay 5 Fallback (R5F) | Read and write | ||||
| Enable Relay 6 Fallback (R6F) | Read and write | ||||
| Enable DQ1 Fallback (LO1F) | Read and write | ||||
| DQ2 Active At (DO2S) | Read and write | ||||
| DQ2 Delay Time (DO2D) | ms | Read and write | |||
| DQ2 Holding Time (DO2H) | ms | Read and write | |||
| Enable DQ2 Fallback (LO2F) | Read and write | ||||
| Enable DQ11 Fallback (D11F) | Read and write | ||||
| Enable DQ12 Fallback (D12F) | Read and write | ||||
| 24V Supply Output (S24V) | Read and write | ||||
| Monitoring Circuit A Assignment (IFAA) | Read and write | ||||
| Monitoring Circuit B Assignment (IFAB) | Read and write | ||||
| Monitoring Circuit C Assignment (IFAC) | Read and write | ||||
| Monitoring Circuit D Assignment (IFAD) | Read and write | ||||
| Monitoring Circuit A Error Monitoring Type (IFMA) | Read and write | ||||
| Monitoring Circuit B Error Monitoring Type (IFMB) | Read and write | ||||
| Monitoring Circuit C Error Monitoring Type (IFMC) | Read and write | ||||
| Monitoring Circuit D Error Monitoring Type (IFMD) | Read and write | ||||
| Monitoring Circuit A Delay After Run (IFDA) | s | Read and write | |||
| Monitoring Circuit B Delay After Run (IFDB) | s | Read and write | |||
| Monitoring Circuit C Delay After Run (IFDC) | s | Read and write | |||
| Monitoring Circuit D Delay After Run (IFDD) | s | Read and write | |||
| Response To Monitoring Circuit A Error (IFRA) | Read and write | ||||
| Response To Monitoring Circuit B Error (IFRB) | Read and write | ||||
| Response To Monitoring Circuit C Error (IFRC) | Read and write | ||||
| Response To Monitoring Circuit D Error (IFRD) | Read and write | ||||
| Analog Input 1 Range (AI1L) | Read and write | ||||
| Analog Input 3 Range (AI3L) | Read and write | ||||
| Analog Input 4 Range (AI4L) | Read and write | ||||
| Analog Input 5 Range (AI5L) | Read and write | ||||
| Reference Type (PGA) | Read and write | ||||
| Frequency Signal Filter (EFI) | ms | Read and write | |||
| Enable PTO Fallback (POFE) | Read and write | ||||
| Enable AQ1 Fallback (AOF1) | Read and write | ||||
| Enable AQ2 Fallback (AOF2) | Read and write | ||||
| HSH Speed Mode (HSOM) | Read and write | ||||
| HSH Torque 1 (HTQ1) | % | Read and write | |||
| HSH Torque 2 (HTQ2) | % | Read and write | |||
| Slewing Control Mode (SLCA) | Read and write | ||||
| Slewing Low Speed Stop (SLLS) | Hz | Read and write | |||
| Slewing Stop Time (SLST) | s | Read and write | |||
| Slewing Fast Deceleration (SLFD) | % | Read and write | |||
| Slewing Speed Feedback Filter (SLGF) | Hz | Read and write | |||
| Slewing Fast Stop Ratio At Low Speed (SLDF) | % | Read and write | |||
| Slewing Speed Gain Threshold (SLBF) | Hz | Read and write | |||
| Slewing Minimum Torque At Start (SLTM) | % | Read and write | |||
| Slewing Torque Boost Minimum Duration (SLTI) | s | Read and write | |||
| Slewing Torque Ramp At Start (SLTR) | s | Read and write | |||
| Slewing Torque Boost Torque Setpoint (SLTQ) | % | Read and write | |||
| Slewing Torque Boost Deactivation Speed Threshold (SLDT) | Hz | Read and write | |||
| Slewing Low Fast Deceleration Threshold (SLLD) | Hz | Read and write | |||
| Slewing Low Condition Speed Threshold For Relay Manageme (SLSR) | Hz | Read and write | |||
| Slewing High Speed Threshold For Ramp Management (SLHF) | Hz | Read and write | |||
| Slewing Torque Boost Switch High Threshold (SLSC) | Hz | Read and write | |||
| Slewing Torque Boost Switch Low Threshold (SLTA) | Hz | Read and write | |||
| Slewing Speed Control Gain Boost (SLRP) | % | Read and write | |||
| Slewing Positioning Ramp Switch Threshold (SLFR) | Hz | Read and write | |||
| Slewing Positioning Deceleration Time (SLDE) | Read and write | ||||
| Slewing Positioning Deceleration Time 2 (SLD2) | Read and write | ||||
| Slewing Fast Deceleration Torque Threshold Deactivation (SLFT) | % | Read and write | |||
| Offset Value Between Motor And Encoder (ASV) | Read and write | ||||
| Alignment Rotational Torque Current (RTC) | % | Read and write | |||
| RCI Round Number (RCRP) | Read and write | ||||
| Weight Sensor Assignment (PES) | Read and write | ||||
| IBR When Weight Loss (IBRA) | Read and write | ||||
| Ext Weight Point 1 X (LP1) | % | Read and write | |||
| Ext Weight Point 1Y (CP1) | Read and write | ||||
| Ext Weight Point 2 X (LP2) | % | Read and write | |||
| Ext Weight Point 2Y (CP2) | Read and write | ||||
| Overmodulation Activation (OVMA) | Read and write | ||||
| Output Voltage Limitation (VLIM) | V | Read and write | |||
| DC Bus Ripple Configuration (DCRC) | Read and write | ||||
| Current Loop Configured Gain (CRB) | Hz | Read and write | |||
| Current Loop Damping Coefficient (CRDR) | % | Read and write | |||
| Use Of An Input Filer (IFI) | Read and write | ||||
| Time Delay Control Assignment (TDCA) | Read and write | ||||
| Time Delay Control Activation Frequency (TCSH) | Hz | Read and write | |||
| Time Delay Control Deactivation Frequency (TCSL) | Hz | Read and write | |||
| Time Delay Control Wire Rope Length (TDCL) | m | Read and write | |||
| Time Delay Control Acceleration Ramp Time (ACCT) | Read and write | ||||
| Time Delay Control Deceleration Ramp Time (DECT) | Read and write | ||||
| Time Delay Control Pendulum Time Period (TDCP) | ms | Read and write | |||
| Time Delay Control Speed Damping Coefficient (TDCR) | % | Read and write | |||
| I2t Actual Integral Load Value (TLOA) | % | Read and write | |||
| I2t Mean Load Value (TLOM) | % | Read and write | |||
| Abort Firmware Update (FWCL) | Read and write | ||||
| Update Firmware (FWAP) | Read | ||||
| HMI Displayed Value Type (MDT) | Read and write | ||||
| Energy Dashboard (EMDT) | Read and write | ||||
| Access Level (LAC) | Read and write | ||||
| Parameters (PVIS) | Read and write | ||||
| Source Configuration (FCSI) | Read and write | ||||
| Save Configuration (SCSI) | Read and write | ||||
| Ethernet Timeout (TOUT) | s | Read and write | |||
| Nothing (FTTS) | Read and write | ||||
| Display Terminal Locked (KLCK) | min | Read and write | |||
| Red Backlight (BCKL) | Read and write | ||||
| IP Mode (IPM) | Read and write | ||||
| IP Mode Ethernet Embd (IM00) | Read and write | ||||
| Ethernet Option IP Mode (IM10) | Read and write | ||||
| Ethernet Rate Data (ARDE) | Read | ||||
| Ethernet Embedded Rx Frames (ERXE) | Read and write | ||||
| Ethernet Embedded Tx Frames (ETXE) | Read and write | ||||
| Ethernet Embedded Error Frames (EERE) | Read and write | ||||
| Ethernet Option Rx Frames (ERXO) | Read and write | ||||
| Ethernet Option Tx Frames (ETXO) | Read and write | ||||
| Ethernet Option Error Frames (EERO) | Read and write | ||||
| ON Lock Response (LKOR) | Read and write | ||||
| ON Lock Time Delay (LKOD) | s | Read and write | |||
| ON Lock Assignment (LKOS) | Read and write |
Loading registers…

Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Record the speed limits and ramp times of every drive in a fleet on a ModbusCloud dashboard.
- Compare the motor data of two drives on the same machine type to find a wrong setting.
- Adjust the acceleration or deceleration time of a conveyor from ModbusCloud without a laptop at the cabinet.
- Keep a history of PID setpoints and limits to see when someone changed the process settings.
- Get an email when a protection setting differs from the value you expect.
Installation
Install the core ATV340 template first and make sure the drive answers on Modbus.
Wire the RJ45 Modbus port of the drive to RS485 A and B of the ModbusCloud Gateway and terminate the bus.
Set Modbus address, baud rate and format on the drive; the factory format is 19200 baud, 8E1 with the address OFF.
In ModbusCloud, add a second Modbus device with the same address and import this template.
Check that low speed, high speed and the ramp times match the drive display.
Things to watch for
The drive does not answer at all. What should I check?
The Modbus address is OFF from the factory, so the drive stays silent until you set it. Then check baud rate and format (default 19200, 8E1), swap A and B if needed and terminate the bus at both ends.
Why does a parameter refuse a new value?
Many settings only accept a change with the motor stopped, and every value must be inside its range. Writing is also off per gateway by default; request it on the Control tab of the gateway. Change one setting at a time and agree changes with whoever runs the machine.
Why do some settings show a plain number instead of text?
Settings with long choice lists, such as input assignments, show the code from the drive parameter list. Look up the code in the ATV340 programming manual or parameter list.
Why does polling get slow with this template?
It holds more than 900 parameters. Settings rarely change, so poll this template much less often than the core template or keep only the settings you need.
More Schneider Electric templates
Want to see how it works?