Schneider Electric Schneider Electric Altivar ATV340 configuration and settings Modbus RTU template

Schneider Electric Altivar ATV340 configuration and settings

Drive setup of the Altivar ATV340: motor data, ramps, speed limits, I/O, PID and protections.

The Schneider Electric Altivar ATV340 is a variable speed drive for machines such as conveyors, hoists and packaging lines. This Modbus RTU template reads its configuration, from motor data and ramps to I/O assignment, PID and protections, and lets you change those settings from ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 19200 baud
Registers
937, read and write
Key readings
Low and high speed · Acceleration and deceleration · Motor nominal data · Input and output assignment · PID settings · Fault handling settings
Available commands
Speed limits · Ramp times · Motor parameters · I/O assignment · PID setpoints · Protection settings
Compatible models
Altivar Machine ATV340 · Schneider Electric Altivar Machine ATV340 variable speed drive
Last updated

Registers (937)

937 read, 898 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Low Speed (LSP)HzRead and write3105FC03 / FC06uint16
High Speed (HSP)HzRead and write3104FC03 / FC06uint16
High Speed 2 (HSP2)HzRead and write15110FC03 / FC06uint16
High Speed 3 (HSP3)HzRead and write15111FC03 / FC06uint16
High Speed 4 (HSP4)HzRead and write15112FC03 / FC06uint16
2 High Speed Assign. (SH2)Read and write
4 High Speed Assign. (SH4)Read and write
Motor Thermal Current (ITH)Read and write
Inertia Factor (SPGU)%Read and write
Speed Proportional Gain (SPG)%Read and write
Speed Time Integral (SIT)msRead and write
K Speed Loop Filter (SFC)Read and write
Inertia Coefficient Of The Application (JACO)Read and write
Speed Loop Type (SSL)Read and write
Estimated Application Inertia (JEST)Read
Application Inertia (JAPL)Read and write
Inertia Multiplying Coefficient (JMUL)Read
Feed Forward Value (FFP)%Read and write
Feed Forward Bandwidth (FFV)%Read and write
Filter Time Of The Estimated Speed (FFH)msRead and write
Filter Time Of The Current (CRTF)msRead and write
Notch Filter Activation (NFA)Read and write
Notch Filter 1 - Frequency (NFF1)HzRead and write
Notch Filter 1 - Bandwidth (NFB1)%Read and write
Notch Filter 1 - Depth (NFD1)%Read and write
Notch Filter 2 - Frequency (NFF2)HzRead and write
Notch Filter 2 - Bandwidth (NFB2)%Read and write
Notch Filter 2 - Depth (NFD2)%Read and write
High Current Threshold (CTD)Read and write
High Torque Threshold (TTH)%Read and write
Low Torque Threshold (TTL)%Read and write
Pulse Warning Threshold (FQL)HzRead and write
Motor Frequency Threshold (FTD)HzRead and write
Frequency Threshold 2 (F2D)HzRead and write
Skip Frequency 2 (JF2)HzRead and write
Skip Frequency (JPF)HzRead and write
Skip Freq. Hysteresis (JFH)HzRead and write
3rd Skip Frequency (JF3)HzRead and write
Motor Standard (BFR)Read and write
Nominal Motor Power (NPR)Read and write
Motor 1 Cosinus Phi (COS)Read and write
Nominal Motor Voltage (UNS)VRead and write
Nominal Motor Current (NCR)Read and write
Nominal Motor Frequency (FRS)HzRead and write
Nominal Motor Speed (NSP)rpmRead and write
Max Frequency (TFR)HzRead and write
Autotuning (TUN)Read and write
Rotation Tune Enable (TUNR)Read and write
First Id Min Current Level In Rotation (IDL1)%Read and write
First Id Max Current Level In Rotation (IDH1)%Read and write
Second Id Min Current Level In Rotation (IDL2)%Read and write
Second Id Max Current Level In Rotation (IDH2)%Read and write
Rotation Tune Type (EFAP)Read and write
Number Of Autotuning Sequence Repetitions (TNBR)Read and write
Tangential Main Inductance (L0A)Read and write
Flux Saturation Curve Coefficient A (ALFA)%Read and write
Flux Saturation Curve Coefficient B (BET0)%Read and write
Automatic Autotune (AUT)Read and write
Autotuning Status (TUS)Read
Rotation Tune Status (TURS)Read
Rotation Tune Status PMSM (TRS2)Read
Rotation Tune Status SynRm (TRS3)Read
Motor Control Type (CTT)Read and write
Volt Point 1 On 5pt V/F (U1)VRead and write
Freq Point 1on 5pt V/F (F1)HzRead and write
Volt Point 2 On 5pt V/F (U2)VRead and write
Freq Point 2 On 5pt V/F (F2)HzRead and write
Volt Point 3 On 5pt V/F (U3)VRead and write
Freq Point 3 On 5pt V/F (F3)HzRead and write
Volt Point 4 On 5pt V/F (U4)VRead and write
Freq Point 4 On 5pt V/F (F4)HzRead and write
Volt Point 5 On 5pt V/F (U5)VRead and write
Freq Point 5 On 5pt V/F (F5)HzRead and write
Sync Motor Nominal Current (NCRS)Read and write
Nominal Synchronous Motor Speed (NSPS)rpmRead and write
Pole Pairs Number (Sync) (PPNS)Read and write
Nominal Motor Torque (TQS)Read and write
Sync. EMF Constant (PHS)Read and write
Sync Motor D Inductance (LDS)Read and write
Sync Motor Q Inductance (LQS)Read and write
Calculated SyncMotor Stator R (RSAS)Read and write
IR Compensation (UFR)%Read and write
Slip Compensation (SLP)%Read and write
Number Of Pairs Of Poles Calculated (PPN)Read
Frequency Loop Gain (FLG)%Read and write
Frequency Loop Stability (STA)%Read and write
AsyncMotor Stator Resistance (RSA)Read and write
Magnetizing Current (IDA)Read and write
AsyncMotor Leakage Inductance (LFA)Read and write
Rotor Time Constant (TRA)Read and write
Synchronous Motor Nominal Freq (FRSS)HzRead
Switching Frequency (SFR)Read and write
Current Limitation (CLI)Read and write
Switching Frequency Type (SFT)Read and write
Motor Noise Reduction (NRD)Read and write
Boost Activation (BOA)Read and write
Motor Surge Limitation (SVL)Read and write
Attenuation Time (SOP)Read and write
Braking Level (VBR)VRead and write
Braking Resistor Monitoring (BRO)Read and write
Braking Resistor Power (BRP)kWRead and write
Braking Resistor Value (BRV)ΩRead and write
Braking Resistor Time Constant (BRTC)sRead and write
Load Sharing (LBA)Read and write
Load Correction (LBC)HzRead and write
Correction Min Speed (LBC1)HzRead and write
Correction Max Speed (LBC2)HzRead and write
Torque Offset (LBC3)%Read and write
Sharing Filter (LBF)msRead and write
Fan Mode (FFM)Read and write
2/3-Wire Control (TCC)Read and write
Type Of 2-Wire Control (TCT)Read and write
Reverse Assignment (RRS)Read and write
Reference Frequency Template Selection (BSP)Read and write
Configuration Of AI1 (AI1T)Read and write
AI1 Voltage Scaling Parameter Of 0% (UIL1)VRead and write
AI1 Voltage Scaling Parameter Of 100% (UIH1)VRead and write
AI1 Filter (AI1F)sRead and write
AI1 Intermediate Point X (AI1E)%Read and write
AI1 Intermediate Point Y (AI1S)%Read and write
Configuration Of AI2 (AI2T)Read and write
AI2 Voltage Scaling Parameter Of 0% (UIL2)VRead and write
AI2 Voltage Scaling Parameter Of 100% (UIH2)VRead and write
AI2 Filter (AI2F)sRead and write
AI2 Intermediate Point X (AI2E)%Read and write
AI2 Intermediate Point Y (AI2S)%Read and write
Configuration Of AI3 (AI3T)Read and write
AI3 Current Scaling Parameter Of 0% (CRL3)mARead and write
AI3 Current Scaling Parameter Of 100% (CRH3)mARead and write
AI3 Filter (AI3F)sRead and write
AI3 Intermediate Point X (AI3E)%Read and write
AI3 Intermediate Point Y (AI3S)%Read and write
AQ1 Assignment (AO1)Read and write
AQ1 Type (AO1T)Read and write
AQ1 Min Output Value (AOL1)mARead and write
AQ1 Max Output Value (AOH1)mARead and write
AQ1 Minimum Output (UOL1)VRead and write
AQ1 Maximum Output (UOH1)VRead and write
Scaling AQ1 Min (ASL1)%Read and write
Scaling AQ1 Max (ASH1)%Read and write
AQ1 Filter (AO1F)sRead and write
Configuration Reference Frequency 1 (FR1)Read and write
Reverse Direction Disable (RIN)Read and write
Stop Key Enable (PST)Read and write
Control Mode Configuration (CHCF)Read and write
Command Switching (CCS)Read and write
Command Channel 1 Assign (CD1)Read and write
Command Channel 2 Assign (CD2)Read and write
Freq Switching Assignment (RFC)Read and write
Configuration Reference Frequency 2 (FR2)Read and write
Copy Ch.1-Ch.2 (COP)Read and write
F1 Key Assignment (FN1)Read and write
F2 Key Assignment (FN2)Read and write
F3 Key Assignment (FN3)Read and write
F4 Key Assignment (FN4)Read and write
HMI Local/Remote Command (BMP)Read and write
Select Switching (1 To 1B) (RCB)Read and write
Configuration Ref. 1B (FR1B)Read and write
Summing Input 2 (SA2)Read and write
Summing Input 3 (SA3)Read and write
Subtract Reference Frequency 2 (DA2)Read and write
Subtract Reference Frequency 3 (DA3)Read and write
Reference Frequency 2 Multiply (MA2)Read and write
Reference Frequency 3 Multiply (MA3)Read and write
Type Of Ramp (RPT)Read and write
Ramp Increment (INR)Read and write
Acceleration Ramp Time (ACC)Read and write
Deceleration Ramp Time (DEC)Read and write
Start ACC Ramp Rounding (TA1)%Read and write
End ACC Ramp Rounding (TA2)%Read and write
Start DEC Ramp Rounding (TA3)%Read and write
End DEC Ramp Rounding (TA4)%Read and write
Ramp 2 Frequency Threshold (FRT)HzRead and write
Ramp Switching Assignment (RPS)Read and write
Acceleration 2 Ramp Time (AC2)Read and write
Deceleration 2 (DE2)Read and write
Decel Ramp Adaptation (BRA)Read and write
Braking Balance (BBA)Read and write
Type Of Stop (STT)Read and write
Freewheel Stop Threshold (FFT)HzRead and write
Freewheel Stop (NST)Read and write
Fast Stop Assignment (FST)Read and write
Fast Stop Ramp Divider (DCF)Read and write
DC Injection Assignment (DCI)Read and write
DC Injection Level 1 (IDC)Read and write
DC Injection Time 1 (TDI)sRead and write
DC Injection Level 2 (IDC2)Read and write
DC Injection Time 2 (TDC)sRead and write
Automatic DC Injection (ADC)Read and write
Auto DC Injection Level 1 (SDC1)Read and write
Auto DC Injection Time 1 (TDC1)sRead and write
Auto DC Injection Level 2 (SDC2)Read and write
Auto DC Injection Time 2 (TDC2)sRead and write
Jog Assignment (JOG)Read and write
Jog Frequency (JGF)HzRead and write
Jog Delay (JGT)sRead and write
2 Preset Freq Assignment (PS2)Read and write
4 Preset Freq Assignment (PS4)Read and write
8 Preset Freq Assignment (PS8)Read and write
16 Preset Freq Assignment (PS16)Read and write
Preset Speed 2 (SP2)HzRead and write
Preset Speed 3 (SP3)HzRead and write
Preset Speed 4 (SP4)HzRead and write
Preset Speed 5 (SP5)HzRead and write
Preset Speed 6 (SP6)HzRead and write
Preset Speed 7 (SP7)HzRead and write
Preset Speed 8 (SP8)HzRead and write
Preset Speed 9 (SP9)HzRead and write
Preset Speed 10 (SP10)HzRead and write
Preset Speed 11 (SP11)HzRead and write
Preset Speed 12 (SP12)HzRead and write
Preset Speed 13 (SP13)HzRead and write
Preset Speed 14 (SP14)HzRead and write
Preset Speed 15 (SP15)HzRead and write
Preset Speed 16 (SP16)HzRead and write
+ Speed Assignment (USP)Read and write
- Speed Assignment (DSP)Read and write
Reference Frequency Save (STR)Read and write
+ Speed Assignment (USI)Read and write
- Speed Assignment (DSI)Read and write
Stop Forward Limit Assignment (LAF)Read and write
Stop Reverse Limit Assignment (LAR)Read and write
Stop Type On Limit Switch (LAS)Read and write
+/- Speed Limitation (SRP)%Read and write
Reference Frequency Memory Assignment (SPM)Read and write
Motor Fluxing Configure (FLU)Read and write
Fluxing Input Assignment (FLI)Read and write
Auto Angle Setting Type (AST)Read and write
Angle Auto-Test (ASA)Read and write
Angle Test Assignment (ASL)Read and write
Angle Setting Activation Mode (ATA)Read and write
Activation Of HF Injection (HFI)Read and write
Bandwidth Of The HF PLL (SPB)%Read and write
Current Level Of The HF Alignment (ILR)%Read and write
Boost Level For IPMA Alignment (SIR)%Read and write
Maximum Current Of PSI Alignment (MCR)%Read and write
Angle Position Error Compensation (PEC)%Read and write
Brake Assignment (BLC)Read and write
Motion Type Selection (BST)Read and write
Brake Contact Input (BCI)Read and write
Brake Release Pulse (BIP)Read and write
Brake Release Current (IBR)Read and write
Rev. Brake Release Curr. (IRD)Read and write
Brake Release Time (BRT)sRead and write
Brake Release Frequency (BIR)HzRead and write
Brake Engage Frequency (BEN)HzRead and write
Brake Engage Delay (TBE)sRead and write
Brake Engage Time (BET)sRead and write
Brake Engage At Reversal (BED)Read and write
Jump At Reversal (JDC)HzRead and write
Brake Engage At 0 Speed (BECD)sRead and write
Time To Restart (TTR)sRead and write
Brake Feedback Filter (FBCI)msRead and write
Brake Hidden (BRH)Read and write
BRH_b4 Frequency Threshold Detection (BFTD)HzRead and write
Load Maintain Time (MDFT)minRead and write
Current Ramp Time (BRR)sRead and write
High Speed Hoisting (HSO)Read and write
Motor Speed Coefficient (COF)%Read and write
Generator Speed Coefficient (COR)%Read and write
Load Measuring Time (TOS)sRead and write
Measurement Speed (OSP)HzRead and write
High Speed I Limit (CLO)Read and write
Current Limit. Frequency (SCL)HzRead and write
Rope Slack Torque Level (RSTL)%Read and write
Rope Slack Configuration (RSD)Read and write
PID Controller Feedback (PIF)Read and write
Minimum PID Feedback (PIF1)Read and write
Maximum PID Feedback (PIF2)Read and write
Minimum PID Process (PIP1)Read and write
Maximum PID Process (PIP2)Read and write
Internal PID Reference (PII)Read and write
Internal PID Reference (RPI)Read and write
PID Proportional Gain (RPG)Read and write
PID Controller Integral Gain (RIG)Read and write
PID Derivative Gain (RDG)Read and write
PID Ramp (PRP)sRead and write
PID Inversion (PIC)Read and write
PID Controller Min. Output (POL)HzRead and write
PID Controller Max. Output (POH)HzRead and write
Minimum Feedback Level Warning (PAL)Read and write
Maximum Feedback Level Warning (PAH)Read and write
PID Error Warning (PER)Read and write
PID Integral Disabled (PIS)Read and write
Predictive Speed Reference (FPI)Read and write
PID Speed Input % Ref (PSR)%Read and write
Auto/Manual Select Input (PAU)Read and write
Manual PID Reference (PIM)Read and write
Low Speed Timeout (TLS)sRead and write
2 PID Preset Assignment (PR2)Read and write
4 PID Preset Assignment (PR4)Read and write
2nd PID Preset Reference (RP2)Read and write
3rd PID Preset Reference (RP3)Read and write
4th PID Preset Reference (RP4)Read and write
Torque Limit. Activation (TLA)Read and write
Torque Increment (INTP)Read and write
Motoring Torque Limit (TLIM)Read and write
Generator Torque Limit (TLIG)Read and write
Reference Torque Assignment (TAA)Read and write
Torque Analog Limit. Activ (TLC)Read and write
Torque/Speed Switching Control Mode (TSS)Read and write
Channel For Torque Reference (TR1)Read and write
Torque Reference Sign Switching (TSD)Read and write
Torque Regulation Negative Deadband (DBN)HzRead and write
Torque Regulation Positive Deadband (DBP)HzRead and write
Torque Ratio (TRT)%Read and write
Torque Ramp Time (TRP)sRead and write
Torque Control Stop Type (TST)Read and write
Response To Torque Control Error (TOB)Read and write
Torque Control Time Out (RTO)sRead and write
Spin Time (SPT)sRead and write
Torque Ratio Assignment (TQR)Read and write
Torque Offset Assignment (TQO)Read and write
Torque Reference Assignment (TRI)Read and write
Torque Reference 2 Channel (TR2)Read and write
Current Limitation 2 (LC2)Read and write
Current Limitation 2 Value (CL2)Read and write
Reference Torque Switch Assignment (TASU)Read and write
Reference Torque 2 Assignment (TAA2)Read and write
Mains Contactor Control (LLC)Read and write
Device Lock Assignment (LES)Read and write
Mains V. Time Out (LCT)sRead and write
Fwd Stop Limit Input Assig (SAF)Read and write
RV Stop Limit Input Assign (SAR)Read and write
Forward Slowdown Limit (DAF)Read and write
Reverse Slowdown Limit (DAR)Read and write
Disable Limit Switch (CLS)Read and write
Stop Type (PAS)Read and write
Deceleration Type (DSF)Read and write
Stop Distance (STD)mRead and write
Rated Linear Speed (NLS)m/sRead and write
Distance Stop Corrector (SFD)%Read and write
Multimotors Selection (CHM)Read and write
2 Configurations Assignt. (CNF1)Read and write
3 Configurations Assignt. (CNF2)Read and write
Autotuning Input Assignment (TUL)Read and write
Fault Reset Input Assignment (RSF)Read and write
Product Restart (RP)Read and write
Product Restart Assignment (RPA)Read and write
Automatic Fault Reset (ATR)Read and write
Fault Reset Time (TAR)Read and write
Catch On Fly (FLR)Read and write
Motor Thermal Monitoring Mode (THT)Read and write
Motor Thermal Threshold (TTD)%Read and write
Motor 2 Thermal Threshold (TTD2)%Read and write
Motor 3 Thermal Threshold (TTD3)%Read and write
Motor 4 Thermal Threshold (TTD4)%Read and write
Motor Overtemp Error Response (OLL)Read and write
Output Phase Loss Assignment (OPL)Read and write
Output Phase Loss Delay (ODT)sRead and write
Input Phase Loss Assignment (IPL)Read and write
Drive Overtemp Error Response (OHL)Read and write
Device Thermal State Warning (THA)%Read and write
External Error Assignment (ETF)Read and write
Device Response To External Error (EPL)Read and write
Response To Undervoltage (USB)Read and write
Evacuation Mains Voltage (URES)Read and write
Undervoltage Level (USL)VRead and write
Undervoltage Timeout (UST)sRead and write
Stop Type On Power Loss (STP)Read and write
Undervolt. Restart Time (TSM)sRead and write
Under V Prevention Level (UPL)VRead and write
Load Slip Detection (SDD)Read and write
Maximum Stop Time (STM)sRead and write
DC Bus Charge Assignment (DCO)Read and write
DC Bus Charge Opt. Time (DCT)sRead and write
DC Bus Maintain Time (TBS)sRead and write
Output Short Circuit Test (STRT)Read and write
Catch On Fly Mode (COFM)Read and write
Response To 4-20mA Loss On AI3 (LFL3)Read and write
Disable Error Detection (INH)Read and write
Response To Fieldbus Module Communication Interruption (CLL)Read and write
Response To CANopen Error (COL)Read and write
Response To Modbus Interruption (SLL)Read and write
Stop Type - Torque/I Limit (SSB)Read and write
Torque/I Limit. Timeout (STO)msRead and write
Response To Autotuning Error (TNL)Read and write
Pairing Password (PPI)Read and write
Fall Back Speed (LFF)HzRead and write
Frequency Meter (FQF)Read and write
Pulse Scaling Divisor (FQC)Read and write
Overspd. Pulse Threshold (FQA)HzRead and write
Pulse Overspeed Delay (TDS)sRead and write
Level Freq. Pulse Ctrl (FDT)HzRead and write
Pulse Threshold Wo Run (FQT)HzRead and write
Dynamic Load Time (TLD)sRead and write
Dynamic Load Threshold (DLD)%Read and write
Dynamic Load Mgt. (DLB)Read and write
Scan Output 1 Address (NCA1)Read and write
Scan Output 2 Address (NCA2)Read and write
Scan Output 3 Address (NCA3)Read and write
Scan Output 4 Address (NCA4)Read and write
Scan Output 5 Address (NCA5)Read and write
Scan Output 6 Address (NCA6)Read and write
Scan Output 7 Address (NCA7)Read and write
Scan Output 8 Address (NCA8)Read and write
Scan Input 1 Address (NMA1)Read and write
Scan Input 2 Address (NMA2)Read and write
Scan Input 3 Address (NMA3)Read and write
Scan Input 4 Address (NMA4)Read and write
Scan Input 5 Address (NMA5)Read and write
Scan Input 6 Address (NMA6)Read and write
Scan Input 7 Address (NMA7)Read and write
Scan Input 8 Address (NMA8)Read and write
Scan Input 1 Address (OMA1)Read and write
Scan Input 2 Address (OMA2)Read and write
Scan Input 3 Address (OMA3)Read and write
Scan Input 4 Address (OMA4)Read and write
Scan Input 5 Address (OMA5)Read and write
Scan Input 6 Address (OMA6)Read and write
Scan Output 1 Address (OCA1)Read and write
Scan Output 2 Address (OCA2)Read and write
Scan Output 3 Address (OCA3)Read and write
Scan Output 4 Address (OCA4)Read and write
Scan Output 5 Address (OCA5)Read and write
Scan Output 6 Address (OCA6)Read and write
Device Modbus Address (ADD)Read and write
Mdb Add Comm. Module (AMOC)Read and write
Modbus Baud Rate (TBR)Read and write
Modbus Format (TFO)Read and write
Modbus Timeout (TTO)sRead and write
Device CANopen Address (ADCO)Read and write
CANopen Baudrate (BDCO)Read and write
CANopen Error (ERCO)Read
Forced Local Assignment (FLO)Read and write
Forced Local Channel Assignment (FLOC)Read and write
Time-Out Forc. Local (FLOT)sRead and write
Device Address (ADRC)Read and write
PPO Profile Used (PRFL)Read and write
Configured Assembly (CIOA)Read and write
Comm. Option Baudrate (BDR)Read and write
Data Rate Used (BDRU)Read and write
Rate And Duplex Setting (RDS)Read and write
Actual Rate And Duplex (ARD)Read
DI1 Delay (L1D)msRead and write
R1 Assignment (R1)Read and write
R2 Assignment (R2)Read and write
DI2 Delay (L2D)msRead and write
R1 Delay Time (R1D)msRead and write
R2 Delay Time (R2D)msRead and write
DI3 Delay (L3D)msRead and write
R1 Active Level (R1S)Read and write
R2 Active Level (R2S)Read and write
DI4 Delay (L4D)msRead and write
R1 Holding Time (R1H)msRead and write
R2 Holding Time (R2H)msRead and write
DI5 Delay (L5D)msRead and write
DI6 Delay (L6D)msRead and write
DI7 Delay (L7D)msRead and write
DI8 Delay (L8D)msRead and write
DQ1 Assignment (DO1)Read and write
DQ2 Assignment (DO2)Read and write
DQ1 Delay Time (DO1D)msRead and write
DQ1 Holding Time (DO1H)msRead and write
DQ1 Active Level (DO1S)Read and write
FRH High Resolution (FRHT)Read
LCR Without Filter (SLCR)Read
RFR Without Filter (SRFR)HzRead
Measured Output Freq. (MMF)HzRead
Motor Torque (% Of Cn Motor In Q12) Without Filter (SOTR)Read
ULN Without Filter (SULN)VRead
OPR Without Filter (SOPR)%Read
Number Of Pulses (PGI)Read and write
AB Encoder Type Configuration (ENS)Read and write
Encoder Usage (ENU)Read and write
Encoder Check (ENC)Read and write
Encoder Coupling Monitoring (ECC)Read and write
Encoder Check Time (ECT)sRead and write
Resolver Poles Nbr (RPPN)Read and write
Encoder Type (UECP)Read and write
Encoder Supply Voltage (UECV)Read and write
Inversion Of Encoder Rotation Direction (ENRI)Read and write
Encoder Feeback Filter Activation (FFA)Read and write
Encoder Feedback Filter Value (FFR)msRead and write
Underload Detection Delay (ULT)sRead and write
Hysteresis Frequency (SRB)HzRead and write
Response To Underload Error (UDL)Read and write
Unld. Freq.Thr. Detection (RMUD)HzRead and write
Unld.Thr. At O Speed (LUL)%Read and write
Unld.Thr. At Nom. Speed (LUN)%Read and write
Overload Detection Delay (TOL)sRead and write
Response To Overload Error (ODL)Read and write
PID Acceleration Time (ACCP)Read and write
AI4 Intermediate Point X (AI4E)%Read and write
AI4 Filter (AI4F)sRead and write
AI4 Intermediate Point Y (AI4S)%Read and write
Configuration Of AI4 (AI4T)Read and write
AI5 Intermediate Point X (AI5E)%Read and write
AI5 Filter (AI5F)sRead and write
AI5 Delinearization Output Level (AI5S)%Read and write
Configuration Of AI5 (AI5T)Read and write
Channel Assignment For Virtual Analog Input AIV1 (AIC1)Read and write
AQ2 Assignment (AO2)Read and write
AQ2 Filter (AO2F)sRead and write
AQ2 Type (AO2T)Read and write
AQ2 Max Output Value (AOH2)mARead and write
AQ2 Min Output Value (AOL2)mARead and write
Scaling AQ2 Max (ASH2)%Read and write
Scaling AQ2 Min (ASL2)%Read and write
Customer Warning Clearing (CAR)Read and write
Configuration Of Customer Warning 1 (CCA1)Read and write
Configuration Of Customer Warning 2 (CCA2)Read and write
Configuration Of Customer Warning 3 (CCA3)Read and write
Configuration Of Customer Warning 4 (CCA4)Read and write
Configuration Of Customer Warning 5 (CCA5)Read and write
Configuration Counter Limit 1 (CCL1)sRead and write
Configuration Counter Limit 2 (CCL2)sRead and write
Configuration Counter Limit 3 (CCL3)sRead and write
Configuration Counter Limit 4 (CCL4)sRead and write
Configuration Counter Limit 5 (CCL5)sRead and write
Configuration Counter Source 1 (CCS1)Read and write
Configuration Counter Source 2 (CCS2)Read and write
Configuration Counter Source 3 (CCS3)Read and write
Configuration Counter Source 4 (CCS4)Read and write
Configuration Counter Source 5 (CCS5)Read and write
Date Time Warning 1 (CDT1)Read and write
Date Time Warning 2 (CDT2)Read and write
Date Time Warning 3 (CDT3)Read and write
Date Time Warning 4 (CDT4)Read and write
Date Time Warning 5 (CDT5)Read and write
AI1 Current Scaling Parameter Of 100% (CRH1)mARead and write
AI4 Current Scaling Parameter Of 100% (CRH4)mARead and write
AI5 Current Scaling Parameter Of 100% (CRH5)mARead and write
AI1 Current Scaling Parameter Of 0% (CRL1)mARead and write
AI4 Current Scaling Parameter Of 0% (CRL4)mARead and write
AI5 Current Scaling Parameter Of 0% (CRL5)mARead and write
Low Current Threshold (CTDL)Read and write
DQ11 Activation Delay (D11D)msRead and write
DQ11 Holding Delay (D11H)msRead and write
DQ11 Status (Output Active Level) (D11S)Read and write
DQ12 Activation Delay (D12D)msRead and write
DQ12 Holding Delay (D12H)msRead and write
DQ12 Status (Output Active Level) (D12S)Read and write
DO11 Assignment (DO11)Read and write
DO12 Assignment (DO12)Read and write
Dual Rating State (DRT)Read and write
CO2 Ratio (ECO2)Read and write
KWh Cost (ECST)Read and write
Ethernet Error Response (ETHL)Read and write
2 Frequency Threshold (F2DL)HzRead and write
Low Freq. Threshold (FTDL)HzRead and write
Ovld Time Before Restart (FTO)minRead and write
Unld Time Before Restart (FTU)minRead and write
Ground Fault Activation (GRFL)%Read and write
NCR Current Scaling (INRC)Read
LFA Inductance Scaling (INRL)Read
NPR Power Scaling (INRP)Read
RSA Resistance Scaling (INRR)Read
Torque Scaling (INRT)Read and write
TRA Time Scaling (INTI)Read
DI11 Delay (L11D)msRead and write
DI12 Delay (L12D)msRead and write
DI13 Delay (L13D)msRead and write
DI14 Delay (L14D)msRead and write
DI15 Delay (L15D)msRead and write
DI16 Delay (L16D)msRead and write
Log Distribution Data 1 (LDD1)Read and write
Log Distribution Data 2 (LDD2)Read and write
Log Distribution Data 3 (LDD3)Read and write
Log Distribution Data 4 (LDD4)Read and write
Logging Distribution State (LDEN)Read and write
Distribution Data Max Value 1 (LDM1)Read and write
Distribution Data Max Value 2 (LDM2)Read and write
Distribution Data Max Value 3 (LDM3)Read and write
Distribution Data Max Value 4 (LDM4)Read and write
Logging Distribution Sample Time (LDST)Read and write
Response To 4-20mA Loss On AI1 (LFL1)Read and write
Response To 4-20mA Loss On AI4 (LFL4)Read and write
Response To 4-20mA Loss On AI5 (LFL5)Read and write
Current Overload Threshold (LOC)%Read and write
Number Of Motor Starts (NSM)Read and write
Sinus Filter Activation (OFI)Read and write
Over-Consumption Threshold (PCAH)%Read and write
Under-Consumption Threshold (PCAL)%Read and write
Over/Under-Consumption Time Delay (PCAT)minRead and write
DI7 Frequency Filter (PFI7)msRead and write
DI8 Frequency Filter (PFI8)msRead and write
Output Phase Rotation (PHR)Read and write
DI7 PulseInput High Frequency (PIH7)Read and write
DI8 PulseInput High Frequency (PIH8)Read and write
DI7 PulseInput Low Frequency (PIL7)HzRead and write
DI8 PulseInput Low Frequency (PIL8)HzRead and write
R3 Assignment (R3)Read and write
R3 Delay Time (R3D)msRead and write
R3 Holding Time (R3H)msRead and write
R3 Active Level (R3S)Read and write
R4 Assignment (R4)Read and write
R4 Delay Time (R4D)msRead and write
R4 Holding Time (R4H)msRead and write
R4 Active Level (R4S)Read and write
R5 Assignment (R5)Read and write
R5 Delay Time (R5D)msRead and write
R5 Holding Time (R5H)msRead and write
R5 Active Level (R5S)Read and write
R6 Assignment (R6)Read and write
R6 Activation Delay Time (R6D)msRead and write
R6 Holding Delay Time (R6H)msRead and write
R6 Active Level (R6S)Read and write
Reference High Threshold (RTD)HzRead and write
Reference Low Threshold (RTDL)HzRead and write
PID Start Ref Frequency (SFS)HzRead and write
Sleep Offset Threshold (SLE)HzRead and write
Motor Stall Max Time (STP1)sRead and write
Stall Monitoring Current Level (STP2)%Read and write
Stall Monitoring Frequency Level (STP3)HzRead and write
Stall Monitoring Activation (STPC)Read and write
Modbus 2 Baud Rate (TBR2)Read and write
Modbus 2 Format (TFO2)Read and write
Thermal Warning Level For AI1 (TH1A)Read and write
Response To Thermal Error For AI1 (TH1B)Read and write
Thermal Warning Level For AI3 (TH3A)Read and write
Thermal Error Level For AI1 (TH1F)Read and write
Response To Thermal Error For AI3 (TH3B)Read and write
Activation Of The Thermal Monitoring On AI1 (TH1S)Read and write
Thermal Error Level For AI3 (TH3F)Read and write
Activation Of The Thermal Monitoring On AI3 (TH3S)Read and write
Thermal Warning Level For AI4 (TH4A)Read and write
Response To Thermal Error For AI4 (TH4B)Read and write
Thermal Error Level For AI4 (TH4F)Read and write
Activation Of The Thermal Monitoring On AI4 (TH4S)Read and write
Thermal Warning Level For AI5 (TH5A)Read and write
Response To Thermal Error For AI5 (TH5B)Read and write
Thermal Error Level For AI5 (TH5F)Read and write
Activation Of The Thermal Monitoring On AI5 (TH5S)Read and write
Type Of Control (TOCT)Read and write
Pulse Without Run Delay (TQB)sRead and write
Ethernet Embedded : Time-Out (TTOB)sRead and write
AI3 Voltage Scaling Parameter Of 100% (UIH3)VRead and write
AI4 Voltage Scaling Parameter Of 100% (UIH4)VRead and write
AI5 Voltage Scaling Parameter Of 100% (UIH5)VRead and write
AI3 Voltage Scaling Parameter Of 0% (UIL3)VRead and write
AI4 Voltage Scaling Parameter Of 0% (UIL4)VRead and write
AI5 Voltage Scaling Parameter Of 0% (UIL5)VRead and write
AQ2 Maximum Output (UOH2)VRead and write
AQ2 Minimum Output (UOL2)VRead and write
Catch On Fly Sensitivity (VCB)VRead and write
Reference Power Without Drive (PREF)Read and write
High Torque (HTQ)%Read and write
Low Torque (LTQ)%Read and write
Braking Resistor Connected (BRC)Read and write
PTO Maximum Output Frequency (PTOH)Read and write
PTO Assignment (PTO)Read and write
SSI Code Type (SSCD)Read and write
SSI Parity (SSCP)Read and write
SSI Frame Size (SSFS)Read and write
Number Of Revolutions (ENMR)Read and write
Turn Bit Resolution (ENTR)Read and write
Resolver Excitation Frequency (REFQ)Read and write
Clock Frequency (ENSP)Read and write
Reset Position Assignment (RPOS)Read and write
AB Encoder Maximum Frequency (ABMF)Read and write
Autotuning Type (TUNT)Read and write
Memo Stop (MSTP)Read and write
Priority Restart (PRST)Read and write
Backlash Mode (BQM)Read and write
Response To Backlash Error (BQFB)Read and write
Backlash Reference Frequency (BQSL)HzRead and write
Backlash Acceleration (BQA)Read and write
Backlash Torque Limitation Value (BQTL)%Read and write
Backlash Torque Limitation Monitoring Delay (BQT)sRead and write
Backlash Start Delay (BQST)sRead and write
Backlash Timeout (BQFD)sRead and write
Backlash Type (BQMM)Read and write
Backlash On Slave(S) Feedback (BQMC)Read and write
Backlash Time (BQMT)sRead and write
PTI Mode (PTIM)Read and write
PTI Direction Inversion (PTII)Read and write
PTI Filter Time Inp (PTIS)Read and write
PTI Low Freq (PTIL)HzRead and write
PTI High Frequency (PTIH)HzRead and write
PTI Filter Time Analog (PTIT)msRead and write
PTO Mode Selection (PTOM)Read and write
PTO Low Frequency (PTOB)HzRead and write
PTO High Frequency (PTOU)HzRead and write
Frequency Min Value (PEIL)Read and write
Frequency Max Value (PEFR)Read and write
M/S Device Selection (MSDN)Read and write
Application Selection (APPT)Read and write
Motor Parameter Choice (MPC)Read and write
Internal Currents Filter Time (CRFA)msRead and write
Autotuning Usage (TUNU)Read and write
Level Of Current For Autotuning (TCR)%Read and write
Alignment Rotational Current Level (RCL)%Read and write
RCI Alignment With Transformer (RCIR)Read and write
RCI Maximum Output Frequency (RCSP)HzRead and write
Encoder Thermal Sensor Type (THET)Read and write
Response To Thermal Error For Encoder (THEB)Read and write
Thermal Error Level For Encoder (THEF)Read and write
Thermal Warning Level For Encoder (THEA)Read and write
Boost (BOO)%Read and write
Boost On Deceleration (BOO2)%Read and write
Frequency Boost (FAB)HzRead and write
External Feed Forward Assignment (TEFF)Read and write
Frequency Of The HF Injection Signal (FRI)HzRead and write
M/S Communication Mode (MSCM)Read and write
Master Or Slave ID Selection (MSID)Read and write
Master Or Slave Selection (MSDT)Read and write
M/S Number Of Slaves (MSSN)Read and write
M/S Master Speed Reference Input Assignment (MSSI)Read and write
M/S Master Torque Reference Input Assignment (MSTI)Read and write
M/S Speed Reference Output Assignment (MSSO)Read and write
M/S Torque Reference Output Assignment (MSTO)Read and write
M/S Local Mode Assignment (MSDI)Read and write
MultiDrive Link Communication Timeout (MLTO)sRead and write
M/S Response To Communication Error (MSCB)Read and write
M/S Response To Device Error (MSDB)Read and write
M/S Device Error Delay (MSDD)sRead and write
M/S Mechanical Coupling Type (MSMC)Read and write
M/S Control Type (MSCT)Read and write
Speed Reference Direction (SSD)Read and write
Torque Reference Offset (TQOP)%Read and write
Torque Filter Activation (TRF)Read and write
Torque Filter Bandwidth (TRW)HzRead and write
M/S Advanced Filter Activation (MSFE)Read and write
M/S Advanced Filter Frequency (MSFF)HzRead and write
M/S Advanced Filter Bandwidth (MSFB)%Read and write
M/S Advanced Filter Depth (MSFD)%Read and write
M/S Advanced Filter Gain (MSFG)%Read and write
M/S Advanced Filter Coefficient (MSFC)%Read and write
M/S Load Balancing Torque Reference Selection (MSIB)Read and write
M/S Master Torque Reference Entry In Control Chain (MSIT)Read and write
M/S Output Torque Reference Selection (MSOT)Read and write
M/S Master Speed Reference Entry In Control Chain (MSIS)Read and write
M/S Output Speed Reference Selection (MSOS)Read and write
Maximum Power In Motor Mode (TPMM)%Read and write
Maximum Power In Generator Mode (TPMG)%Read and write
PTO Min Output Frequency (PTOL)Read and write
Resolver Transformation Ratio (TRES)Read and write
Sincos Lines Count (UELC)Read and write
Stop On Next Top Z Detection (TOST)Read and write
Drive Overload Monitoring Activation (TLOL)Read and write
Terminal Modbus: Word Order (TWO)Read and write
Terminal Modbus 2: Word Order (TWO2)Read and write
FDR Error Status (FDR1)Read
FDR Operating State (FDS1)Read
FDR Action (FDA1)Read and write
Enable FDR Function (FDV1)Read and write
Control Scope Assignment 1 (PSA1)Read and write
Control Scope Assignment 2 (PSA2)Read and write
Control Scope Assignment 3 (PSA3)Read and write
Control Scope Assignment 4 (PSA4)Read and write
Upload Rights (ULR)Read and write
Download Rights (DLR)Read and write
Drive Systems Pre-Settings Unlock (PSRT)Read and write
AIV1 Assignment (AV1A)Read
PTO Assignment (PTOE)Read and write
Modbus Reference Frequency (LFR1)Read and write
CANopen Reference Frequency (LFR2)Read and write
Communication Module Reference Frequency (LFR3)Read and write
Embedded Ethernet Reference Frequency (LFR5)Read and write
Extended Fault Reset Activation (HRFC)Read and write
Fieldbus Communication Loss Fallback Channel (AFFL)Read and write
AI Loss Inhibition (INLF)Read and write
Emb. Enc. Type (EECP)Read and write
Emb. Enc. Numb. Of Pulses (EPGI)Read and write
Emb. Enc. Sincos Lines Cnt (EELC)Read and write
Emb. Enc. Usage (EENU)Read and write
Emb. Enc. Rotation Inv. (EERI)Read and write
Emb. Enc. Supply Volt. (EECV)Read and write
Torque Filter Time (TQTF)msRead and write
Field Weakening Correction Bandwidth (FWBW)HzRead and write
Maximum Braking Current Level (BDCL)%Read and write
Slip Compensation In Generator Mode (SLPC)Read and write
Nominal Mechanical Power (NMP)Read
Nominal Motor Torque Scaling (TQNC)Read and write
Advanced Motor Control (AEMC)Read and write
Speed Measurement Feedback Performance (SMFP)Read and write
Speed Measurement Bandwidth (SMBW)HzRead and write
Profidrive Profile - RFG Tolerance Parameter (PTR)%Read and write
Profidrive Profile - RFG Tmax Parameter (PTM)Read and write
Profinet ModbusTCP Word Order (TWOP)Read and write
IPar Service Activation (IPAV)Read and write
IPar Autosave Activation (IPAS)Read and write
IPAR Local Configuration (ICFG)Read and write
IPar Response To Detected Error (IPAF)Read and write
IPar Autosave Timer (IPAT)Read and write
IPar Service Status (IPAE)Read and write
IPAR Action (IPAA)Read and write
IPAR Action Status (IPAC)Read
IPAR Configuration Selection (IPAM)Read and write
PNU 1000 Behavior (PNU)Read and write
Embedded RSTP Configuration (ST0C)Read and write
RSTP Option Module Configuration (ST1C)Read and write
Receive PDO3-1 (RP31)Read
Receive PDO3-2 (RP32)Read
Receive PDO3-3 (RP33)Read
Receive PDO3-4 (RP34)Read
Transmit PDO3-1 (TP31)Read
Transmit PDO3-2 (TP32)Read
Transmit PDO3-3 (TP33)Read
Transmit PDO3-4 (TP34)Read
Number Of TX PDO (NBTP)Read
Number Of RX PDO (NBRP)Read
Configuration Of Virtual Analog Input AIV1 (AV1T)Read and write
EPF2 (External Error Detected By Fieldbus) Info (EPF2)Read and write
DC Injection Angle (TAFI)°Read and write
Delay To Close O/P Cont. (DBS)sRead and write
Delay To Open Contactor (DAS)sRead and write
Output Contactor Fdbk (RCA)Read and write
Output Contactor Control Assignment (OCC)Read and write
Power Backup Input Assignment (RFT)Read and write
Power Backup Voltage (RSU)VRead and write
Power Backup Reference Frequency (RSP)HzRead and write
Torque Filter Time (TPFV)msRead and write
Motor Run Time (RTHH)hRead and write
Power-On Time (PTHH)hRead and write
Memo Slowdown (MSLO)Read and write
Brake Relay Feedback (BRI)Read and write
Brake Relay Feedback Filter (FBRI)msRead and write
Id Current Magnetic Saturation Curve For SynRM Law (Point (ID1)Read and write
Id Current Magnetic Saturation Curve For SynRM Law (Point (ID2)Read and write
Id Current Magnetic Saturation Curve For SynRM Law (Point (ID3)Read and write
Id Current Magnetic Saturation Curve For SynRM Law (Point (ID4)Read and write
Id Current Magnetic Saturation Curve For SynRM Law (Point (ID5)Read and write
PHS Scaling (IPHS)Read and write
Ld Inductance For Magnetic Saturation Curve SynRM Law (Po (LD1)Read and write
Ld Inductance For Magnetic Saturation Curve SynRM Law (Po (LD2)Read and write
Ld Inductance For Magnetic Saturation Curve SynRM Law (Po (LD3)Read and write
Ld Inductance For Magnetic Saturation Curve SynRM Law (Po (LD4)Read and write
Ld Inductance For Magnetic Saturation Curve SynRM Law (Po (LD5)Read and write
Rotation Tune Reference Frequency (TLFR)HzRead and write
Tune Period Interval (TPD)hRead and write
Speed Maintain'S Behavior (RLS)HzRead and write
Enable Relay 1 Fallback (R1F)Read and write
Enable Relay 2 Fallback (R2F)Read and write
Enable Relay 3 Fallback (R3F)Read and write
Enable Relay 4 Fallback (R4F)Read and write
Enable Relay 5 Fallback (R5F)Read and write
Enable Relay 6 Fallback (R6F)Read and write
Enable DQ1 Fallback (LO1F)Read and write
DQ2 Active At (DO2S)Read and write
DQ2 Delay Time (DO2D)msRead and write
DQ2 Holding Time (DO2H)msRead and write
Enable DQ2 Fallback (LO2F)Read and write
Enable DQ11 Fallback (D11F)Read and write
Enable DQ12 Fallback (D12F)Read and write
24V Supply Output (S24V)Read and write
Monitoring Circuit A Assignment (IFAA)Read and write
Monitoring Circuit B Assignment (IFAB)Read and write
Monitoring Circuit C Assignment (IFAC)Read and write
Monitoring Circuit D Assignment (IFAD)Read and write
Monitoring Circuit A Error Monitoring Type (IFMA)Read and write
Monitoring Circuit B Error Monitoring Type (IFMB)Read and write
Monitoring Circuit C Error Monitoring Type (IFMC)Read and write
Monitoring Circuit D Error Monitoring Type (IFMD)Read and write
Monitoring Circuit A Delay After Run (IFDA)sRead and write
Monitoring Circuit B Delay After Run (IFDB)sRead and write
Monitoring Circuit C Delay After Run (IFDC)sRead and write
Monitoring Circuit D Delay After Run (IFDD)sRead and write
Response To Monitoring Circuit A Error (IFRA)Read and write
Response To Monitoring Circuit B Error (IFRB)Read and write
Response To Monitoring Circuit C Error (IFRC)Read and write
Response To Monitoring Circuit D Error (IFRD)Read and write
Analog Input 1 Range (AI1L)Read and write
Analog Input 3 Range (AI3L)Read and write
Analog Input 4 Range (AI4L)Read and write
Analog Input 5 Range (AI5L)Read and write
Reference Type (PGA)Read and write
Frequency Signal Filter (EFI)msRead and write
Enable PTO Fallback (POFE)Read and write
Enable AQ1 Fallback (AOF1)Read and write
Enable AQ2 Fallback (AOF2)Read and write
HSH Speed Mode (HSOM)Read and write
HSH Torque 1 (HTQ1)%Read and write
HSH Torque 2 (HTQ2)%Read and write
Slewing Control Mode (SLCA)Read and write
Slewing Low Speed Stop (SLLS)HzRead and write
Slewing Stop Time (SLST)sRead and write
Slewing Fast Deceleration (SLFD)%Read and write
Slewing Speed Feedback Filter (SLGF)HzRead and write
Slewing Fast Stop Ratio At Low Speed (SLDF)%Read and write
Slewing Speed Gain Threshold (SLBF)HzRead and write
Slewing Minimum Torque At Start (SLTM)%Read and write
Slewing Torque Boost Minimum Duration (SLTI)sRead and write
Slewing Torque Ramp At Start (SLTR)sRead and write
Slewing Torque Boost Torque Setpoint (SLTQ)%Read and write
Slewing Torque Boost Deactivation Speed Threshold (SLDT)HzRead and write
Slewing Low Fast Deceleration Threshold (SLLD)HzRead and write
Slewing Low Condition Speed Threshold For Relay Manageme (SLSR)HzRead and write
Slewing High Speed Threshold For Ramp Management (SLHF)HzRead and write
Slewing Torque Boost Switch High Threshold (SLSC)HzRead and write
Slewing Torque Boost Switch Low Threshold (SLTA)HzRead and write
Slewing Speed Control Gain Boost (SLRP)%Read and write
Slewing Positioning Ramp Switch Threshold (SLFR)HzRead and write
Slewing Positioning Deceleration Time (SLDE)Read and write
Slewing Positioning Deceleration Time 2 (SLD2)Read and write
Slewing Fast Deceleration Torque Threshold Deactivation (SLFT)%Read and write
Offset Value Between Motor And Encoder (ASV)Read and write
Alignment Rotational Torque Current (RTC)%Read and write
RCI Round Number (RCRP)Read and write
Weight Sensor Assignment (PES)Read and write
IBR When Weight Loss (IBRA)Read and write
Ext Weight Point 1 X (LP1)%Read and write
Ext Weight Point 1Y (CP1)Read and write
Ext Weight Point 2 X (LP2)%Read and write
Ext Weight Point 2Y (CP2)Read and write
Overmodulation Activation (OVMA)Read and write
Output Voltage Limitation (VLIM)VRead and write
DC Bus Ripple Configuration (DCRC)Read and write
Current Loop Configured Gain (CRB)HzRead and write
Current Loop Damping Coefficient (CRDR)%Read and write
Use Of An Input Filer (IFI)Read and write
Time Delay Control Assignment (TDCA)Read and write
Time Delay Control Activation Frequency (TCSH)HzRead and write
Time Delay Control Deactivation Frequency (TCSL)HzRead and write
Time Delay Control Wire Rope Length (TDCL)mRead and write
Time Delay Control Acceleration Ramp Time (ACCT)Read and write
Time Delay Control Deceleration Ramp Time (DECT)Read and write
Time Delay Control Pendulum Time Period (TDCP)msRead and write
Time Delay Control Speed Damping Coefficient (TDCR)%Read and write
I2t Actual Integral Load Value (TLOA)%Read and write
I2t Mean Load Value (TLOM)%Read and write
Abort Firmware Update (FWCL)Read and write
Update Firmware (FWAP)Read
HMI Displayed Value Type (MDT)Read and write
Energy Dashboard (EMDT)Read and write
Access Level (LAC)Read and write
Parameters (PVIS)Read and write
Source Configuration (FCSI)Read and write
Save Configuration (SCSI)Read and write
Ethernet Timeout (TOUT)sRead and write
Nothing (FTTS)Read and write
Display Terminal Locked (KLCK)minRead and write
Red Backlight (BCKL)Read and write
IP Mode (IPM)Read and write
IP Mode Ethernet Embd (IM00)Read and write
Ethernet Option IP Mode (IM10)Read and write
Ethernet Rate Data (ARDE)Read
Ethernet Embedded Rx Frames (ERXE)Read and write
Ethernet Embedded Tx Frames (ETXE)Read and write
Ethernet Embedded Error Frames (EERE)Read and write
Ethernet Option Rx Frames (ERXO)Read and write
Ethernet Option Tx Frames (ETXO)Read and write
Ethernet Option Error Frames (EERO)Read and write
ON Lock Response (LKOR)Read and write
ON Lock Time Delay (LKOD)sRead and write
ON Lock Assignment (LKOS)Read and write

Loading registers…

The ModbusCloud Gateway, front at an angle, with the RS485 terminal and the antenna connectors

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Use cases

  • Record the speed limits and ramp times of every drive in a fleet on a ModbusCloud dashboard.
  • Compare the motor data of two drives on the same machine type to find a wrong setting.
  • Adjust the acceleration or deceleration time of a conveyor from ModbusCloud without a laptop at the cabinet.
  • Keep a history of PID setpoints and limits to see when someone changed the process settings.
  • Get an email when a protection setting differs from the value you expect.

Installation

  1. Install the core ATV340 template first and make sure the drive answers on Modbus.

  2. Wire the RJ45 Modbus port of the drive to RS485 A and B of the ModbusCloud Gateway and terminate the bus.

  3. Set Modbus address, baud rate and format on the drive; the factory format is 19200 baud, 8E1 with the address OFF.

  4. In ModbusCloud, add a second Modbus device with the same address and import this template.

  5. Check that low speed, high speed and the ramp times match the drive display.

Things to watch for

The drive does not answer at all. What should I check?

The Modbus address is OFF from the factory, so the drive stays silent until you set it. Then check baud rate and format (default 19200, 8E1), swap A and B if needed and terminate the bus at both ends.

Why does a parameter refuse a new value?

Many settings only accept a change with the motor stopped, and every value must be inside its range. Writing is also off per gateway by default; request it on the Control tab of the gateway. Change one setting at a time and agree changes with whoever runs the machine.

Why do some settings show a plain number instead of text?

Settings with long choice lists, such as input assignments, show the code from the drive parameter list. Look up the code in the ATV340 programming manual or parameter list.

Why does polling get slow with this template?

It holds more than 900 parameters. Settings rarely change, so poll this template much less often than the core template or keep only the settings you need.

Want to see how it works?

Electrician working in an open distribution board