Schneider Electric Schneider Electric PowerLogic PM5300 Modbus RTU template

Schneider Electric PowerLogic PM5300

Measures energy, power, demand and harmonics in low-voltage switchboards.

The Schneider Electric PowerLogic PM5300 is a three-phase power meter that measures voltage, current, power, energy, demand and harmonics in low-voltage switchboards. This Modbus RTU template reads all real-time values, energy counters per tariff, peak demand, THD, harmonics and min and max values in ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 19200 baud
Registers
920, read only
Key readings
Current per phase · Voltage L-L and L-N · Active power · Power factor · Frequency · Active energy · Peak demand · THD voltage and current
Compatible models
PM5310 · PM5320 · PM5330 · PM5331 · PM5340 · PM5341 · Schneider Electric PowerLogic PM5310 · Schneider Electric PowerLogic PM5320 · Schneider Electric PowerLogic PM5330 · Schneider Electric PowerLogic PM5331 · Schneider Electric PowerLogic PM5340 · Schneider Electric PowerLogic PM5341
Last updated

Registers (920)

920 read, 0 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Current AARead2999FC03float32
Current BARead3001FC03float32
Current CARead3003FC03float32
Current NARead3005FC03float32
Current GARead3007FC03float32
Current AvgARead
Current Unbalance A%Read
Current Unbalance B%Read
Current Unbalance C%Read
Current Unbalance Worst%Read
Voltage A-BVRead
Voltage B-CVRead
Voltage C-AVRead
Voltage L-L AvgVRead
Voltage A-NVRead
Voltage B-NVRead
Voltage C-NVRead
Voltage L-N AvgVRead
Voltage Unbalance A-B%Read
Voltage Unbalance B-C%Read
Voltage Unbalance C-A%Read
Voltage Unbalance L-L Worst%Read
Voltage Unbalance A-N%Read
Voltage Unbalance B-N%Read
Voltage Unbalance C-N%Read
Voltage Unbalance L-N Worst%Read
Active Power AkWRead
Active Power BkWRead
Active Power CkWRead
Active Power TotalkWRead
Reactive Power AkvarRead
Reactive Power BkvarRead
Reactive Power CkvarRead
Reactive Power TotalkvarRead
Apparent Power AkVARead
Apparent Power BkVARead
Apparent Power CkVARead
Apparent Power TotalkVARead
Power Factor ARead
Power Factor BRead
Power Factor CRead
Power Factor TotalRead
Displacement Power Factor ARead
Displacement Power Factor BRead
Displacement Power Factor CRead
Displacement Power Factor TotalRead
FrequencyHzRead
Power Factor Total IECRead
Power Factor Total Lead LagRead
Power Factor Total IEC (Int)Read
Power Factor Total Lead Lag (Int)Read
Accumulated Energy Reset Date/TimeRead
Active Energy Delivered (Into Load)WhRead
Active Energy Received (Out of Load)WhRead
Active Energy Delivered + ReceivedWhRead
Active Energy Delivered - ReceivedWhRead
Reactive Energy DeliveredvarhRead
Reactive Energy ReceivedvarhRead
Reactive Energy Delivered + ReceivedvarhRead
Reactive Energy Delivered - ReceivedvarhRead
Apparent Energy DeliveredVAhRead
Apparent Energy ReceivedVAhRead
Apparent Energy Delivered + ReceivedVAhRead
Apparent Energy Delivered - ReceivedVAhRead
Active Energy Delivered (Into Load) (Float)kWhRead
Active Energy Received (Out of Load) (Float)kWhRead
Active Energy Delivered + Received (Float)kWhRead
Active Energy Delivered - Received (Float)kWhRead
Reactive Energy Delivered (Float)kvarhRead
Reactive Energy Received (Float)kvarhRead
Reactive Energy Delivered + Received (Float)kvarhRead
Reactive Energy Delivered - Received (Float)kvarhRead
Apparent Energy Delivered (Float)kVAhRead
Apparent Energy Received (Float)kVAhRead
Apparent Energy Delivered + Received (Float)kVAhRead
Apparent Energy Delivered - Received (Float)kVAhRead
Power Demand MethodRead
Power Demand Interval DurationminRead
Power Demand Subinterval DurationminRead
Power Demand Elapsed Time in IntervalsRead
Power Demand Elapsed Time in SubintervalsRead
Power Demand Peak Reset Date/TimeRead
Current Demand MethodRead
Current Demand Interval DurationminRead
Current Demand Subinterval DurationminRead
Current Demand Elapsed Time in IntervalsRead
Current Demand Elapsed Time in SubintervalsRead
Current Demand Peak Reset Date/TimeRead
Active Power Demand System AssignmentRead
Active Power Register Number of Metered QuantityRead
Active Power Units CodeRead
Active Power Last DemandkWRead
Active Power Present DemandkWRead
Active Power Predicted DemandkWRead
Active Power Peak DemandkWRead
Active Power Peak Demand DateTimeRead
Reactive Power Demand System AssignmentRead
Reactive Power Register Number of Metered QuantityRead
Reactive Power Units CodeRead
Reactive Power Last DemandkvarRead
Reactive Power Present DemandkvarRead
Reactive Power Predicted DemandkvarRead
Reactive Power Peak DemandkvarRead
Reactive Power Peak Demand DateTimeRead
Apparent Power Demand System AssignmentRead
Apparent Power Register Number of Metered QuantityRead
Apparent Power Units CodeRead
Apparent Power Last DemandkVARead
Apparent Power Present DemandkVARead
Apparent Power Predicted DemandkVARead
Apparent Power Peak DemandkVARead
Apparent Power Peak Demand DateTimeRead
Current Avg Demand System AssignmentRead
Current Avg Register Number of Metered QuantityRead
Current Avg Units CodeRead
Current Avg Last DemandARead
Current Avg Present DemandARead
Current Avg Predicted DemandARead
Current Avg Peak DemandARead
Current Avg Peak Demand DateTimeRead
HS FrequencyHzRead
THD Current A%Read
THD Current B%Read
THD Current C%Read
THD Current N%Read
THD Current G%Read
THD-R Current A%Read
THD-R Current B%Read
THD-R Current C%Read
THD-R Current N%Read
THD-R Current G%Read
Total Demand Distortion%Read
THD Voltage A-B%Read
THD Voltage B-C%Read
THD Voltage C-A%Read
THD Voltage L-L%Read
THD Voltage A-N%Read
THD Voltage B-N%Read
THD Voltage C-N%Read
THD Voltage L-N%Read
THD-R Voltage A-B%Read
THD-R Voltage B-C%Read
THD-R Voltage C-A%Read
THD-R Voltage L-L%Read
THD-R Voltage A-N%Read
THD-R Voltage B-N%Read
THD-R Voltage C-N%Read
THD-R Voltage L-N%Read
Voltage A-B, H1 Magnitude, %%Read
Voltage A-B, H2 Magnitude, %%Read
Voltage A-B, H3 Magnitude, %%Read
Voltage A-B, H4 Magnitude, %%Read
Voltage A-B, H5 Magnitude, %%Read
Voltage A-B, H6 Magnitude, %%Read
Voltage A-B, H7 Magnitude, %%Read
Voltage A-B, H8 Magnitude, %%Read
Voltage A-B, H9 Magnitude, %%Read
Voltage A-B, H10 Magnitude, %%Read
Voltage A-B, H11 Magnitude, %%Read
Voltage A-B, H12 Magnitude, %%Read
Voltage A-B, H13 Magnitude, %%Read
Voltage A-B, H14 Magnitude, %%Read
Voltage A-B, H15 Magnitude, %%Read
Voltage A-B, H16 Magnitude, %%Read
Voltage A-B, H17 Magnitude, %%Read
Voltage A-B, H18 Magnitude, %%Read
Voltage A-B, H19 Magnitude, %%Read
Voltage A-B, H20 Magnitude, %%Read
Voltage A-B, H21 Magnitude, %%Read
Voltage A-B, H22 Magnitude, %%Read
Voltage A-B, H23 Magnitude, %%Read
Voltage A-B, H24 Magnitude, %%Read
Voltage A-B, H25 Magnitude, %%Read
Voltage A-B, H26 Magnitude, %%Read
Voltage A-B, H27 Magnitude, %%Read
Voltage A-B, H28 Magnitude, %%Read
Voltage A-B, H29 Magnitude, %%Read
Voltage A-B, H30 Magnitude, %%Read
Voltage A-B, H31 Magnitude, %%Read
Voltage B-C, H1 Magnitude, %%Read
Voltage B-C, H2 Magnitude, %%Read
Voltage B-C, H3 Magnitude, %%Read
Voltage B-C, H4 Magnitude, %%Read
Voltage B-C, H5 Magnitude, %%Read
Voltage B-C, H6 Magnitude, %%Read
Voltage B-C, H7 Magnitude, %%Read
Voltage B-C, H8 Magnitude, %%Read
Voltage B-C, H9 Magnitude, %%Read
Voltage B-C, H10 Magnitude, %%Read
Voltage B-C, H11 Magnitude, %%Read
Voltage B-C, H12 Magnitude, %%Read
Voltage B-C, H13 Magnitude, %%Read
Voltage B-C, H14 Magnitude, %%Read
Voltage B-C, H15 Magnitude, %%Read
Voltage B-C, H16 Magnitude, %%Read
Voltage B-C, H17 Magnitude, %%Read
Voltage B-C, H18 Magnitude, %%Read
Voltage B-C, H19 Magnitude, %%Read
Voltage B-C, H20 Magnitude, %%Read
Voltage B-C, H21 Magnitude, %%Read
Voltage B-C, H22 Magnitude, %%Read
Voltage B-C, H23 Magnitude, %%Read
Voltage B-C, H24 Magnitude, %%Read
Voltage B-C, H25 Magnitude, %%Read
Voltage B-C, H26 Magnitude, %%Read
Voltage B-C, H27 Magnitude, %%Read
Voltage B-C, H28 Magnitude, %%Read
Voltage B-C, H29 Magnitude, %%Read
Voltage B-C, H30 Magnitude, %%Read
Voltage B-C, H31 Magnitude, %%Read
Voltage C-A, H1 Magnitude, %%Read
Voltage C-A, H2 Magnitude, %%Read
Voltage C-A, H3 Magnitude, %%Read
Voltage C-A, H4 Magnitude, %%Read
Voltage C-A, H5 Magnitude, %%Read
Voltage C-A, H6 Magnitude, %%Read
Voltage C-A, H7 Magnitude, %%Read
Voltage C-A, H8 Magnitude, %%Read
Voltage C-A, H9 Magnitude, %%Read
Voltage C-A, H10 Magnitude, %%Read
Voltage C-A, H11 Magnitude, %%Read
Voltage C-A, H12 Magnitude, %%Read
Voltage C-A, H13 Magnitude, %%Read
Voltage C-A, H14 Magnitude, %%Read
Voltage C-A, H15 Magnitude, %%Read
Voltage C-A, H16 Magnitude, %%Read
Voltage C-A, H17 Magnitude, %%Read
Voltage C-A, H18 Magnitude, %%Read
Voltage C-A, H19 Magnitude, %%Read
Voltage C-A, H20 Magnitude, %%Read
Voltage C-A, H21 Magnitude, %%Read
Voltage C-A, H22 Magnitude, %%Read
Voltage C-A, H23 Magnitude, %%Read
Voltage C-A, H24 Magnitude, %%Read
Voltage C-A, H25 Magnitude, %%Read
Voltage C-A, H26 Magnitude, %%Read
Voltage C-A, H27 Magnitude, %%Read
Voltage C-A, H28 Magnitude, %%Read
Voltage C-A, H29 Magnitude, %%Read
Voltage C-A, H30 Magnitude, %%Read
Voltage C-A, H31 Magnitude, %%Read
Voltage A-N, H1 Magnitude, %%Read
Voltage A-N, H2 Magnitude, %%Read
Voltage A-N, H3 Magnitude, %%Read
Voltage A-N, H4 Magnitude, %%Read
Voltage A-N, H5 Magnitude, %%Read
Voltage A-N, H6 Magnitude, %%Read
Voltage A-N, H7 Magnitude, %%Read
Voltage A-N, H8 Magnitude, %%Read
Voltage A-N, H9 Magnitude, %%Read
Voltage A-N, H10 Magnitude, %%Read
Voltage A-N, H11 Magnitude, %%Read
Voltage A-N, H12 Magnitude, %%Read
Voltage A-N, H13 Magnitude, %%Read
Voltage A-N, H14 Magnitude, %%Read
Voltage A-N, H15 Magnitude, %%Read
Voltage A-N, H16 Magnitude, %%Read
Voltage A-N, H17 Magnitude, %%Read
Voltage A-N, H18 Magnitude, %%Read
Voltage A-N, H19 Magnitude, %%Read
Voltage A-N, H20 Magnitude, %%Read
Voltage A-N, H21 Magnitude, %%Read
Voltage A-N, H22 Magnitude, %%Read
Voltage A-N, H23 Magnitude, %%Read
Voltage A-N, H24 Magnitude, %%Read
Voltage A-N, H25 Magnitude, %%Read
Voltage A-N, H26 Magnitude, %%Read
Voltage A-N, H27 Magnitude, %%Read
Voltage A-N, H28 Magnitude, %%Read
Voltage A-N, H29 Magnitude, %%Read
Voltage A-N, H30 Magnitude, %%Read
Voltage A-N, H31 Magnitude, %%Read
Voltage B-N, H1 Magnitude, %%Read
Voltage B-N, H2 Magnitude, %%Read
Voltage B-N, H3 Magnitude, %%Read
Voltage B-N, H4 Magnitude, %%Read
Voltage B-N, H5 Magnitude, %%Read
Voltage B-N, H6 Magnitude, %%Read
Voltage B-N, H7 Magnitude, %%Read
Voltage B-N, H8 Magnitude, %%Read
Voltage B-N, H9 Magnitude, %%Read
Voltage B-N, H10 Magnitude, %%Read
Voltage B-N, H11 Magnitude, %%Read
Voltage B-N, H12 Magnitude, %%Read
Voltage B-N, H13 Magnitude, %%Read
Voltage B-N, H14 Magnitude, %%Read
Voltage B-N, H15 Magnitude, %%Read
Voltage B-N, H16 Magnitude, %%Read
Voltage B-N, H17 Magnitude, %%Read
Voltage B-N, H18 Magnitude, %%Read
Voltage B-N, H19 Magnitude, %%Read
Voltage B-N, H20 Magnitude, %%Read
Voltage B-N, H21 Magnitude, %%Read
Voltage B-N, H22 Magnitude, %%Read
Voltage B-N, H23 Magnitude, %%Read
Voltage B-N, H24 Magnitude, %%Read
Voltage B-N, H25 Magnitude, %%Read
Voltage B-N, H26 Magnitude, %%Read
Voltage B-N, H27 Magnitude, %%Read
Voltage B-N, H28 Magnitude, %%Read
Voltage B-N, H29 Magnitude, %%Read
Voltage B-N, H30 Magnitude, %%Read
Voltage B-N, H31 Magnitude, %%Read
Voltage C-N, H1 Magnitude, %%Read
Voltage C-N, H2 Magnitude, %%Read
Voltage C-N, H3 Magnitude, %%Read
Voltage C-N, H4 Magnitude, %%Read
Voltage C-N, H5 Magnitude, %%Read
Voltage C-N, H6 Magnitude, %%Read
Voltage C-N, H7 Magnitude, %%Read
Voltage C-N, H8 Magnitude, %%Read
Voltage C-N, H9 Magnitude, %%Read
Voltage C-N, H10 Magnitude, %%Read
Voltage C-N, H11 Magnitude, %%Read
Voltage C-N, H12 Magnitude, %%Read
Voltage C-N, H13 Magnitude, %%Read
Voltage C-N, H14 Magnitude, %%Read
Voltage C-N, H15 Magnitude, %%Read
Voltage C-N, H16 Magnitude, %%Read
Voltage C-N, H17 Magnitude, %%Read
Voltage C-N, H18 Magnitude, %%Read
Voltage C-N, H19 Magnitude, %%Read
Voltage C-N, H20 Magnitude, %%Read
Voltage C-N, H21 Magnitude, %%Read
Voltage C-N, H22 Magnitude, %%Read
Voltage C-N, H23 Magnitude, %%Read
Voltage C-N, H24 Magnitude, %%Read
Voltage C-N, H25 Magnitude, %%Read
Voltage C-N, H26 Magnitude, %%Read
Voltage C-N, H27 Magnitude, %%Read
Voltage C-N, H28 Magnitude, %%Read
Voltage C-N, H29 Magnitude, %%Read
Voltage C-N, H30 Magnitude, %%Read
Voltage C-N, H31 Magnitude, %%Read
Current A, H1 Magnitude, %%Read
Current A, H2 Magnitude, %%Read
Current A, H3 Magnitude, %%Read
Current A, H4 Magnitude, %%Read
Current A, H5 Magnitude, %%Read
Current A, H6 Magnitude, %%Read
Current A, H7 Magnitude, %%Read
Current A, H8 Magnitude, %%Read
Current A, H9 Magnitude, %%Read
Current A, H10 Magnitude, %%Read
Current A, H11 Magnitude, %%Read
Current A, H12 Magnitude, %%Read
Current A, H13 Magnitude, %%Read
Current A, H14 Magnitude, %%Read
Current A, H15 Magnitude, %%Read
Current A, H16 Magnitude, %%Read
Current A, H17 Magnitude, %%Read
Current A, H18 Magnitude, %%Read
Current A, H19 Magnitude, %%Read
Current A, H20 Magnitude, %%Read
Current A, H21 Magnitude, %%Read
Current A, H22 Magnitude, %%Read
Current A, H23 Magnitude, %%Read
Current A, H24 Magnitude, %%Read
Current A, H25 Magnitude, %%Read
Current A, H26 Magnitude, %%Read
Current A, H27 Magnitude, %%Read
Current A, H28 Magnitude, %%Read
Current A, H29 Magnitude, %%Read
Current A, H30 Magnitude, %%Read
Current A, H31 Magnitude, %%Read
Current B, H1 Magnitude, %%Read
Current B, H2 Magnitude, %%Read
Current B, H3 Magnitude, %%Read
Current B, H4 Magnitude, %%Read
Current B, H5 Magnitude, %%Read
Current B, H6 Magnitude, %%Read
Current B, H7 Magnitude, %%Read
Current B, H8 Magnitude, %%Read
Current B, H9 Magnitude, %%Read
Current B, H10 Magnitude, %%Read
Current B, H11 Magnitude, %%Read
Current B, H12 Magnitude, %%Read
Current B, H13 Magnitude, %%Read
Current B, H14 Magnitude, %%Read
Current B, H15 Magnitude, %%Read
Current B, H16 Magnitude, %%Read
Current B, H17 Magnitude, %%Read
Current B, H18 Magnitude, %%Read
Current B, H19 Magnitude, %%Read
Current B, H20 Magnitude, %%Read
Current B, H21 Magnitude, %%Read
Current B, H22 Magnitude, %%Read
Current B, H23 Magnitude, %%Read
Current B, H24 Magnitude, %%Read
Current B, H25 Magnitude, %%Read
Current B, H26 Magnitude, %%Read
Current B, H27 Magnitude, %%Read
Current B, H28 Magnitude, %%Read
Current B, H29 Magnitude, %%Read
Current B, H30 Magnitude, %%Read
Current B, H31 Magnitude, %%Read
Current C, H1 Magnitude, %%Read
Current C, H2 Magnitude, %%Read
Current C, H3 Magnitude, %%Read
Current C, H4 Magnitude, %%Read
Current C, H5 Magnitude, %%Read
Current C, H6 Magnitude, %%Read
Current C, H7 Magnitude, %%Read
Current C, H8 Magnitude, %%Read
Current C, H9 Magnitude, %%Read
Current C, H10 Magnitude, %%Read
Current C, H11 Magnitude, %%Read
Current C, H12 Magnitude, %%Read
Current C, H13 Magnitude, %%Read
Current C, H14 Magnitude, %%Read
Current C, H15 Magnitude, %%Read
Current C, H16 Magnitude, %%Read
Current C, H17 Magnitude, %%Read
Current C, H18 Magnitude, %%Read
Current C, H19 Magnitude, %%Read
Current C, H20 Magnitude, %%Read
Current C, H21 Magnitude, %%Read
Current C, H22 Magnitude, %%Read
Current C, H23 Magnitude, %%Read
Current C, H24 Magnitude, %%Read
Current C, H25 Magnitude, %%Read
Current C, H26 Magnitude, %%Read
Current C, H27 Magnitude, %%Read
Current C, H28 Magnitude, %%Read
Current C, H29 Magnitude, %%Read
Current C, H30 Magnitude, %%Read
Current C, H31 Magnitude, %%Read
Min/Max Reset DatetimeRead
Min Current AARead
Min Current BARead
Min Current CARead
Min Current NARead
Min Current GARead
Min Current AvgARead
Min Current Unbalance A%Read
Min Current Unbalance B%Read
Min Current Unbalance C%Read
Min Current Unbalance Worst%Read
Min Voltage A-BVRead
Min Voltage B-CVRead
Min Voltage C-AVRead
Min Voltage L-L AvgVRead
Min Voltage A-NVRead
Min Voltage B-NVRead
Min Voltage C-NVRead
Min Voltage L-N AvgVRead
Min Voltage Unbalance A-B%Read
Min Voltage Unbalance B-C%Read
Min Voltage Unbalance C-A%Read
Min Voltage Unbalance L-L Worst%Read
Min Voltage Unbalance A-N%Read
Min Voltage Unbalance B-N%Read
Min Voltage Unbalance C-N%Read
Min Voltage Unbalance L-N Worst%Read
Min Active Power AkWRead
Min Active Power BkWRead
Min Active Power CkWRead
Min Active Power TotalkWRead
Min Reactive Power AkvarRead
Min Reactive Power BkvarRead
Min Reactive Power CkvarRead
Min Reactive Power TotalkvarRead
Min Apparent Power AkVARead
Min Apparent Power BkVARead
Min Apparent Power CkVARead
Min Apparent Power TotalkVARead
Min Power Factor ARead
Min Power Factor BRead
Min Power Factor CRead
Min Power Factor TotalRead
Min Displacement Power Factor ARead
Min Displacement Power Factor BRead
Min Displacement Power Factor CRead
Min Displacement PF TotalRead
Min THD Current A%Read
Min THD Current B%Read
Min THD Current C%Read
Min THD Current N%Read
Min THD Current G%Read
Min THD-R Current A%Read
Min THD-R Current B%Read
Min THD-R Current C%Read
Min THD-R Current N%Read
Min THD-R Current G%Read
Min Total Demand Distortion%Read
Min THD Voltage A-B%Read
Min THD Voltage B-C%Read
Min THD Voltage C-A%Read
Min THD Voltage L-L Avg%Read
Min THD Voltage A-N%Read
Min THD Voltage B-N%Read
Min THD Voltage C-N%Read
Min THD Voltage L-N Avg%Read
Min THD-R Voltage A-B%Read
Min THD-R Voltage B-C%Read
Min THD-R Voltage C-A%Read
Min THD-R Voltage L-L Avg%Read
Min THD-R Voltage A-N%Read
Min THD-R Voltage B-N%Read
Min THD-R Voltage C-N%Read
Min THD-R Voltage L-N Avg%Read
Min FrequencyHzRead
Max Current AARead
Max Current BARead
Max Current CARead
Max Current NARead
Max Current GARead
Max Current AvgARead
Max Current Unbalance A%Read
Max Current Unbalance B%Read
Max Current Unbalance C%Read
Max Current Unbalance Worst%Read
Max Voltage A-BVRead
Max Voltage B-CVRead
Max Voltage C-AVRead
Max Voltage L-L AvgVRead
Max Voltage A-NVRead
Max Voltage B-NVRead
Max Voltage C-NVRead
Max Voltage L-N AvgVRead
Max Voltage Unbalance A-B%Read
Max Voltage Unbalance B-C%Read
Max Voltage Unbalance C-A%Read
Max Voltage Unbalance L-L Worst%Read
Max Voltage Unbalance A-N%Read
Max Voltage Unbalance B-N%Read
Max Voltage Unbalance C-N%Read
Max Voltage Unbalance L-N Worst%Read
Max Active Power AkWRead
Max Active Power BkWRead
Max Active Power CkWRead
Max Active Power TotalkWRead
Max Reactive Power AkvarRead
Max Reactive Power BkvarRead
Max Reactive Power CkvarRead
Max Reactive Power TotalkvarRead
Max Apparent Power AkVARead
Max Apparent Power BkVARead
Max Apparent Power CkVARead
Max Apparent Power TotalkVARead
Max Power Factor ARead
Max Power Factor BRead
Max Power Factor CRead
Max Power Factor TotalRead
Max Displacement Power Factor ARead
Max Displacement Power Factor BRead
Max Displacement Power Factor CRead
Max Displacement PF TotalRead
Max THD Current A%Read
Max THD Current B%Read
Max THD Current C%Read
Max THD Current N%Read
Max THD Current G%Read
Max THD-R Current A%Read
Max THD-R Current B%Read
Max THD-R Current C%Read
Max THD-R Current N%Read
Max THD-R Current G%Read
Max Total Demand Distortion%Read
Max THD Voltage A-B%Read
Max THD Voltage B-C%Read
Max THD Voltage C-A%Read
Max THD Voltage L-L%Read
Max THD Voltage A-N%Read
Max THD Voltage B-N%Read
Max THD Voltage C-N%Read
Max THD Voltage L-N%Read
Max THD-R Voltage A-B%Read
Max THD-R Voltage B-C%Read
Max THD-R Voltage C-A%Read
Max THD-R Voltage L-L%Read
Max THD-R Voltage A-N%Read
Max THD-R Voltage B-N%Read
Max THD-R Voltage C-N%Read
Max THD-R Voltage L-N%Read
Max FrequencyHzRead
Digital Input Status Validity - Base UnitRead
Digital Input Status - Base UnitRead
Digital Output Status Validity - Base UnitRead
Digital Output Status - Base UnitRead
Standard - 1 second Group 1 ValidityRead
Standard - 1 second Group 1Read
Standard - 1 second Group 2 ValidityRead
Standard - 1 second Group 2Read
Unary ValidityRead
UnaryRead
Digital Group 1 ValidityRead
Digital Group 1Read
Processor Loading%Read
Meter Self-Test Word 1Read
Meter Self-Test Word 2Read
Meter Self-Test Word 3Read
Meter Self-Test Word 4Read
Meter Self-Test Word 5Read
TOU/MT ModeRead
TOU/MT Energy Active RateRead
TOU/MT Energy Reset Date/TimeRead
Active Energy Delivered Rate 1WhRead
Active Energy Delivered Rate 2WhRead
Active Energy Delivered Rate 3WhRead
Active Energy Delivered Rate 4WhRead
Active Energy Received Rate 1WhRead
Active Energy Received Rate 2WhRead
Active Energy Received Rate 3WhRead
Active Energy Received Rate 4WhRead
Reactive Energy Delivered Rate 1varhRead
Reactive Energy Delivered Rate 2varhRead
Reactive Energy Delivered Rate 3varhRead
Reactive Energy Delivered Rate 4varhRead
Reactive Energy Received Rate 1varhRead
Reactive Energy Received Rate 2varhRead
Reactive Energy Received Rate 3varhRead
Reactive Energy Received Rate 4varhRead
Apparent Energy Delivered Rate 1VAhRead
Apparent Energy Delivered Rate 2VAhRead
Apparent Energy Delivered Rate 3VAhRead
Apparent Energy Delivered Rate 4VAhRead
Apparent Energy Received Rate 1VAhRead
Apparent Energy Received Rate 2VAhRead
Apparent Energy Received Rate 3VAhRead
Apparent Energy Received Rate 4VAhRead
MT Day Type Rate 1Read
MT Start Time Rate 1Read
MT End Time Rate 1Read
MT Start Month Rate1Read
MT Start Day Rate 1Read
MT End Month Rate 1Read
MT End Day Rate 1Read
MT Day Type Rate 2Read
MT Start Time Rate 2Read
MT End Time Rate 2Read
MT Start Month Rate2Read
MT Start Day Rate 2Read
MT End Month Rate 2Read
MT End Day Rate 2Read
MT Day Type Rate 3Read
MT Start Time Rate 3Read
MT End Time Rate 3Read
MT Start Month Rate3Read
MT Start Day Rate 3Read
MT End Month Rate 3Read
MT End Day Rate 3Read
MT Day Type Rate 4Read
MT Start Time Rate 4Read
MT End Time Rate 4Read
MT Start Month Rate4Read
MT Start Day Rate 4Read
MT End Month Rate 4Read
MT End Day Rate 4Read
Active Energy Delivered Rate 1 (Float)kWhRead
Active Energy Delivered Rate 2 (Float)kWhRead
Active Energy Delivered Rate 3 (Float)kWhRead
Active Energy Delivered Rate 4 (Float)kWhRead
Active Energy Received Rate 1 (Float)kWhRead
Active Energy Received Rate 2 (Float)kWhRead
Active Energy Received Rate 3 (Float)kWhRead
Active Energy Received Rate 4 (Float)kWhRead
Reactive Energy Delivered Rate 1 (Float)kvarhRead
Reactive Energy Delivered Rate 2 (Float)kvarhRead
Reactive Energy Delivered Rate 3 (Float)kvarhRead
Reactive Energy Delivered Rate 4 (Float)kvarhRead
Reactive Energy Received Rate 1 (Float)kvarhRead
Reactive Energy Received Rate 2 (Float)kvarhRead
Reactive Energy Received Rate 3 (Float)kvarhRead
Reactive Energy Received Rate 4 (Float)kvarhRead
Apparent Energy Delivered Rate 1 (Float)kVAhRead
Apparent Energy Delivered Rate 2 (Float)kVAhRead
Apparent Energy Delivered Rate 3 (Float)kVAhRead
Apparent Energy Delivered Rate 4 (Float)kVAhRead
Apparent Energy Received Rate 1 (Float)kVAhRead
Apparent Energy Received Rate 2 (Float)kVAhRead
Apparent Energy Received Rate 3 (Float)kVAhRead
Apparent Energy Received Rate 4 (Float)kVAhRead
Meter NameRead
Meter ModelRead
ManufacturerRead
Product ID NumberRead
Hardware DetectedRead
Supported FeaturesRead
Manufacturing Unit IdRead
Serial NumberRead
Date of ManufactureRead
Hardware RevisionRead
Production History 01Read
Production History 02Read
Production History 03Read
Production History 04Read
Production History 05Read
Production History 06Read
Production History 07Read
Production History 08Read
Production History 09Read
Production History 10Read
Production History 11Read
Production History 12Read
Production History 13Read
Production History 14Read
Production History 15Read
Production History 16Read
Production History 17Read
Production History 18Read
Production History 19Read
Production History 20Read
Manufacturing ChecksumRead
OS Present Firmware Version (DLF Format) X.Y.TRead
OS Present Version X MajorRead
OS Present Version Y MinorRead
OS Present Version Z QualityRead
OS Present Version T InternalRead
OS Previous Firmware Version (DLF Format) X.Y.TRead
OS Previous Version X MajorRead
OS Previous Version Y MinorRead
OS Previous Version Z QualityRead
OS Previous Version T InternalRead
OS Date/Time of Last Firmware DownloadRead
Language Present Firmware Version (DLF Format) X.Y.TRead
Language Present Version X MajorRead
Language Present Version Y MinorRead
Language Present Version Z QualityRead
Language Present Version T InternalRead
Language Previous Firmware Version (DLF Format) X.Y.TRead
Language Previous Version X MajorRead
Language Previous Version Y MinorRead
Language Previous Version Z QualityRead
Language Previous Version T InternalRead
Language Date/Time of Last Firmware DownloadRead
Language ChecksumRead
Language Bridge Code VersionRead
Date/Time of Firmware Download 01Read
Firmware Version 01Read
Communications Channel 01Read
Status of Download 01Read
Date/Time of Firmware Download 02Read
Firmware Version 02Read
Communications Channel 02Read
Status of Download 02Read
Date/Time of Firmware Download 03Read
Firmware Version 03Read
Communications Channel 03Read
Status of Download 03Read
Date/Time of Firmware Download 04Read
Firmware Version 04Read
Communications Channel 04Read
Status of Download 04Read
Date/Time of Firmware Download 05Read
Firmware Version 05Read
Communications Channel 05Read
Status of Download 05Read
Date/Time of Firmware Download 06Read
Firmware Version 06Read
Communications Channel 06Read
Status of Download 06Read
Date/Time of Firmware Download 07Read
Firmware Version 07Read
Communications Channel 07Read
Status of Download 07Read
Date/Time of Firmware Download 08Read
Firmware Version 08Read
Communications Channel 08Read
Status of Download 08Read
Date/Time of Firmware Download 09Read
Firmware Version 09Read
Communications Channel 09Read
Status of Download 09Read
Date/Time of Firmware Download 10Read
Firmware Version 10Read
Communications Channel 10Read
Status of Download 10Read
Download CounterRead
Last Unit Restart DateTimeRead
Number of Metering System RestartsRead
Number of Control Power FailuresRead
Date/Time of Last Control Power FailureRead
Duration of Last Control Power FailuresRead
Cause of Last Meter ResetRead
Date/Time 7-Reg YearRead
Date/Time 7-Reg MonthRead
Date/Time 7-Reg DaydRead
Date/Time 7-Reg HourhRead
Date/Time 7-Reg MinuteminRead
Date/Time 7-Reg SecondsRead
Date/Time 7-Reg MillisecondmsRead
Date/Time 4-Reg YearRead
Date/Time 4-Reg Month & DayRead
Date/Time 4-Reg Hour & MinuteRead
Date/Time 4-Reg MillisecondsRead
Setup PasswordRead
Energy Reset PasswordRead
Demand Reset PasswordRead
Min/Max Reset PasswordRead
Revenue Security StatusRead
Active Load TimersRead
Meter Operation TimersRead
Cycle CountRead
Number of PhasesRead
Number of WiresRead
Power System ConfigurationRead
Nominal FrequencyHzRead
Nominal VoltageVRead
Nominal CurrentARead
Nominal Power FactorRead
Normal Phase RotationRead
Number VTsRead
VT PrimaryVRead
VT SecondaryVRead
Number CTsRead
CT PrimaryARead
CT SecondaryARead
CT Location for 1 or 2 CT MeteringRead
VT Location for 1 or 2 VT MeteringRead
VT Connection TypeRead
Peak Current Demand Over Last YearARead
Active Load Timer SetpointARead
Alarm / Energy LED ModeRead
Pulse Channel 1 Energy ChannelRead
Pulse Channel 1 Digital Output AssociationRead
Pulse Channel 1 Pulse WeightRead
Pulse Channel 2 Energy ChannelRead
Pulse Channel 2 Digital Output AssociationRead
Pulse Channel 2 Pulse WeightRead
Pulse Channel 3 Energy ChannelRead
Pulse Channel 3 Digital Output AssociationRead
Pulse Channel 3 Pulse WeightRead
HMI Model PresentRead
HMI Contrast SettingRead
HMI LanguageRead
HMI Date FormatRead
HMI Time FormatRead
HMI IEC/IEEE ModeRead
HMI Screen TimeoutminRead
HMI Backlight TimeoutminRead
HMI Language 01Read
HMI Language 02Read
HMI Language 03Read
HMI Language 04Read
HMI Language 05Read
HMI Language 06Read
HMI Language 07Read
HMI Language 08Read
QR Code Screen EnableRead
RS-485 Comm Port (M/S) ProtocolRead
RS-485 Comm Port (M/S) AddressRead
RS-485 Comm Port (M/S) Baud RateRead
RS-485 Comm Port (M/S) ParityRead
Number of Multi-tariff Rates ActiveRead
Number of Digital Inputs Used to Control Multi-tariffRead
DI Demand System 1 (Power)Read
DI Demand System 2 (Current)Read
DO Demand System 1 (Power)Read
DO Demand System 2 (Current)Read
DI1 TypeRead
DI1 Control ModeRead
DI1 LabelRead
DI1 Debounce TimemsRead
DI2 TypeRead
DI2 Control ModeRead
DI2 LabelRead
DI2 Debounce TimemsRead
Digital Input Status - Base Unit (I/O Status)Read
DI1 CountRead
DI1 On TimesRead
DI2 CountRead
DI2 On TimesRead
DO1 TypeRead
DO1 LabelRead
DO1 Enable/DisableRead
DO1 Behavioral ModeRead
DO1 On Time For Timed ModesRead
DO2 TypeRead
DO2 LabelRead
DO2 Enable/DisableRead
DO2 Behavioral ModeRead
DO2 On Time For Timed ModesRead
DO3 TypeRead
DO3 LabelRead
DO3 Enable/DisableRead
DO3 Behavioral ModeRead
DO3 On Time For Timed ModesRead
DO4 TypeRead
DO4 LabelRead
DO4 Enable/DisableRead
DO4 Behavioral ModeRead
DO4 On Time For Timed ModesRead
Digital Output Status - Base Unit (I/O Status)Read
DO1 Operating Mode StatusRead
DO1 Control Mode StatusRead
DO1 Behavioral Mode StatusRead
DO1 CountRead
DO1 On TimesRead
DO2 Operating Mode StatusRead
DO2 Control Mode StatusRead
DO2 Behavioral Mode StatusRead
DO2 CountRead
DO2 On TimesRead
DO3 Operating Mode StatusRead
DO3 Control Mode StatusRead
DO3 Behavioral Mode StatusRead
DO3 CountRead
DO3 On TimesRead
DO4 Operating Mode StatusRead
DO4 Control Mode StatusRead
DO4 Behavioral Mode StatusRead
DO4 CountRead
DO4 On TimesRead
Logging StatusRead
Allocated File SizeRead
Allocated Record SizeRead
Record Management MethodRead
File StatusRead
Number of records in fileRead
First Record Sequence NumberRead
Last Record Sequence NumberRead
Topic ModeRead
Start TimeminRead
Stop TimesRead
Interval Control MinutesminRead
Interval Control SecondssRead
Date/Time Last clearRead
Record Item 1Read
Record Item 2Read

Loading registers…

The ModbusCloud Gateway, front at an angle, with the RS485 terminal and the antenna connectors

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Use cases

  • Show power, current and power factor per phase of a switchboard on a ModbusCloud dashboard.
  • Keep a year of energy history per tariff to report consumption per building or tenant.
  • Get an email when peak demand passes the contracted capacity of the connection.
  • Alert when voltage THD rises above a limit so you can look for nonlinear loads.
  • Compare current unbalance between phases over weeks to plan load redistribution.
  • Raise an alarm when a digital input of the meter changes, such as a breaker trip contact.

Installation

  1. Connect the RS485 terminals of the meter to the RS485 port of the ModbusCloud Gateway: D1 (+) to A, D0 (-) to B, common to ground, with a 120 ohm terminator at the end of the bus.

  2. For a PM5320, PM5340 or PM5341, connect the meter to the same network as the Gateway and note its IP address.

  3. On the meter display, set the Modbus address, baud rate and parity under the communication setup; the factory setting is address 1, 19200 baud, even parity.

  4. In ModbusCloud, add a Modbus device on the Gateway, choose the PowerLogic PM5300 template and enter the address and serial settings, or the IP address and port 502.

  5. Check that current, voltage and frequency show plausible values and that the active energy counter rises under load.

Things to watch for

Why does the meter not answer on the RS485 bus?

Check that address, baud rate and parity in ModbusCloud match the meter display (default 1, 19200, even). Swap D0 and D1 if nothing comes back, and make sure the bus has a terminator at both ends. Only the PM5310, PM5330 and PM5331 have RS485; the other models use Ethernet.

Why do some values read as NaN or a very large number?

The meter returns a not-available value when a quantity does not exist in the wiring setup, such as line to neutral voltage on a three-wire delta system or neutral current without a neutral CT. Check the power system configuration on the meter.

Can I change CT ratios or the demand interval from ModbusCloud?

The setup values are readable, but the PM5300 changes them through its command interface, not by writing the register directly. Change the settings on the meter display or with the configuration software of Schneider Electric, and read them back in ModbusCloud.

Can I read several PM5300 meters on one bus?

Yes. Give each meter its own Modbus address and the same baud rate and parity, wire them in a line with a terminator at both ends, and add each meter as a separate Modbus device in ModbusCloud. Up to 32 devices fit on one RS485 line.