Agrowtek Agrowtek GCX Controller Modbus TCP template

Agrowtek GCX Controller

Cultivation controller that shares the values of each connected sensor, relay and pump over Modbus TCP.

The Agrowtek GCX is a cultivation controller for greenhouses and indoor farms that runs climate, lighting, irrigation and dosing with GrowNET sensors, relays and pumps. This Modbus TCP template reads the values, output states and inputs of one connected device per unit ID, and lets you set output throttles, force outputs on or off and calibrate sensors from ModbusCloud.

Protocol
Modbus TCP
Connection
Ethernet, Modbus TCP
Registers
64, read and write
Key readings
Sensor values per device · Output states · Digital inputs · Device name
Available commands
Output throttle · Force output on or off · Sensor calibration
Compatible models
GCX · GCX+ · GrowNET devices on a GCX: SXC, SXE, SXW, SXH, PHX, RD8i, VXi, ADi, DXI8 and others
Last updated

Registers (64)

57 read, 31 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Integer Value 1Read
Integer Value 2Read
Integer Value 3Read
Integer Value 4Read
Integer Value 5Read
Integer Value 6Read
Integer Value 7Read
Integer Value 8Read
Float Value 1Read
Float Value 2Read
Float Value 3Read
Float Value 4Read
Float Value 5Read
Float Value 6Read
Float Value 7Read
Float Value 8Read
Output 1 StatusRead
Output 2 StatusRead
Output 3 StatusRead
Output 4 StatusRead
Output 5 StatusRead
Output 6 StatusRead
Output 7 StatusRead
Output 8 StatusRead
Input 1Read
Input 2Read
Input 3Read
Input 4Read
Input 5Read
Input 6Read
Input 7Read
Input 8Read
Throttle Channel 1Read and write
Throttle Channel 2Read and write
Throttle Channel 3Read and write
Throttle Channel 4Read and write
Throttle Channel 5Read and write
Throttle Channel 6Read and write
Throttle Channel 7Read and write
Throttle Channel 8Read and write
Output 1 Force OffRead and write
Output 2 Force OffRead and write
Output 3 Force OffRead and write
Output 4 Force OffRead and write
Output 5 Force OffRead and write
Output 6 Force OffRead and write
Output 7 Force OffRead and write
Output 8 Force OffRead and write
Output 1 Force OnRead and write
Output 2 Force OnRead and write
Output 3 Force OnRead and write
Output 4 Force OnRead and write
Output 5 Force OnRead and write
Output 6 Force OnRead and write
Output 7 Force OnRead and write
Output 8 Force OnRead and write
Offset Calibration 1Write
Offset Calibration 2Write
Offset Calibration 3Write
Offset Calibration 4Write
Span Calibration 2Write
Span Calibration 3Write
Span Calibration 4Write
Device NameRead

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Bring the climate, water and output values of a GCX into one ModbusCloud dashboard with your other sites.
  • Get an email or webhook when a sensor value on the GCX leaves your band, with one rule for each limit.
  • Keep 365 days of history for every GrowNET device on the GCX.
  • Force an output on or off from the portal during maintenance and hand it back to automatic afterwards.
  • Watch the digital inputs of GCX input modules with a rule on the change condition.

Installation

  1. On the GCX, open the network settings, enable the TCP/IP server and note the IP address. Use port 502 or 4040.

  2. Connect the GCX by Ethernet to the same network as the ModbusCloud Gateway.

  3. Look up the device address of each GrowNET device on the GCX. On a GCX+, add 100 for devices on bus 1.

  4. In ModbusCloud, add one Modbus device per GrowNET device with protocol TCP, the GCX IP address, the port and the device address as unit ID, and import this template.

  5. Rename the values after what they measure on that device and remove the registers it does not have.

Things to watch for

The GCX does not answer on Modbus TCP. What should I check?

Check that the TCP/IP command server is enabled in the GCX network settings and that you use port 502 or 4040 as set there. The GCX must be reachable from the network of the ModbusCloud Gateway; a fixed IP address reserved in the router keeps it at the same address.

Some values give an illegal data address error.

Each device only has the values, outputs and inputs it really has; asking for more returns an illegal data address error. Remove the registers that the device does not use from its Modbus device in ModbusCloud.

Which unit ID belongs to which device?

The unit ID is the device address on the GCX, 1 to 100 on bus 0. On a GCX+ devices on bus 1 use the address plus 100, so address 20 on bus 1 is unit ID 120. Unit IDs from 201 hold control functions and recipes, which this template does not cover.

How do I switch an output from ModbusCloud?

Write 1 to the Force On or Force Off coil of that output; setting one clears the other. Write 0 to both to return the output to automatic. A throttle above 0 also puts the channel in manual on, and 0 is not accepted there. Writing is off per gateway by default; request it for the gateway in the portal.

Why are some values much too large?

The whole-number values are scaled per device type: temperature and pH by 100, humidity by 10. The floating-point values carry the real reading, so use those on your dashboards.