Agrowtek Agrowtek SXC Climate Sensor Modbus RTU template

Agrowtek SXC Climate Sensor

Canopy climate sensor for temperature, humidity, PPFD light, CO2 and leaf temperature.

The Agrowtek SXC is an aspirated climate sensor that hangs above the crop canopy in greenhouses and grow rooms and measures air temperature, humidity, PPFD light and, as options, CO2 and leaf temperature. This Modbus RTU template reads all sensor values and identification through the LX2 ModLINK, and lets you write calibration offsets, the units toggle and the humidity sensor heater from ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 19200 baud
Registers
29, read and write
Key readings
Air temperature · Relative humidity · PPFD light level · CO2 concentration · Leaf temperature
Available commands
Calibration offsets · Temperature units · Humidity sensor heater · Modbus address
Compatible models
SXC
Last updated

Registers (29)

17 read, 13 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Temperature°CRead
Relative Humidity%RHRead
Lightµmol/m²/sRead
CO2ppmRead
Leaf Temperature°CRead
Sensor Value 6Read
Temperature Float°CRead
Relative Humidity Float%RHRead
Light Floatµmol/m²/sRead
CO2 FloatppmRead
Leaf Temperature Float°CRead
Toggle UnitsWrite
Humidity Sensor HeaterWrite
Temperature Offset Calibration°CWrite
Humidity Offset Calibration%RHWrite
Light Offset Calibrationµmol/m²/sWrite
CO2 Offset CalibrationppmWrite
Leaf Temperature Offset Calibration°CWrite
Temperature Analog Output CalibrationWrite
Humidity Analog Output CalibrationWrite
Light Analog Output CalibrationWrite
CO2 Analog Output CalibrationWrite
Clear CalibrationWrite
Device AddressRead and write
Serial NumberRead
Date of ManufactureRead
Hardware VersionRead
Firmware VersionRead
Device ModelRead

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Show canopy temperature, humidity, light and CO2 for each greenhouse section on one ModbusCloud dashboard.
  • Get an email or webhook when CO2 falls below your enrichment target or rises above a safety limit.
  • Compare leaf and air temperature over 365 days of history to judge screens, heating and lighting.
  • Detect light leaks during the dark period with an alarm rule on the PPFD value.
  • Catch a failed temperature or humidity element with a rule on the value 9999, which the sensor reports when it fails.
  • Correct a drifting reading with an offset written from ModbusCloud after checking it against a reference.

Installation

  1. Hang the SXC above the crop canopy and connect its GrowNET port with a standard RJ45 cable to an Agrowtek LX2 ModLINK, directly or through an HX8 hub.

  2. Wire TX/RX+ and TX/RX- of the LX2 to the RS485 terminals of the ModbusCloud Gateway and terminate the bus at both ends. Power the LX2 with 24 Vdc, which the SXC needs for its fan and optional sensors.

  3. Give the sensor its own address from 1 to 247 with the AgrowLINK utility and an LX1 USB AgrowLINK, or write it to the address register at broadcast address 254 while it is the only device on the bus.

  4. In ModbusCloud, add a Modbus device with protocol RTU, the sensor address, 19200 baud, 8 data bits, no parity and 1 stop bit, and import this template.

  5. Check that temperature and humidity show plausible values. If your SXC has no CO2 or PLIR option, remove those registers from the Modbus device.

Things to watch for

The sensor does not answer through the LX2. What should I check?

Check 19200 baud, no parity, 1 stop bit and the sensor address in ModbusCloud; the LX2 may have been set to another speed with the ModLINK utility. Swap TX/RX+ and TX/RX- if nothing comes back, terminate the RS485 bus, and make sure every GrowNET device behind the LX2 has its own address.

The temperature looks far too high. Is it in Fahrenheit?

Probably. The sensor units can be toggled between °C and °F, and the template labels the value °C. Writing 1 to Toggle Units switches the temperature back. A value of 9999 means a failed sensor; a failed CO2 sensor reads 0.

Why do I see every value twice?

The SXC gives each value as a scaled whole number and as a floating-point value with the same reading. Keep the one you want on your dashboards and remove the other from the Modbus device if you do not need it.

Can I calibrate the sensor from ModbusCloud?

Yes. Write the correct value to the offset register of that sensor, for example 25.00 °C for temperature, and the sensor corrects itself. CO2 only accepts 400 ppm in fresh outdoor air. Writing 1 to Clear Calibration restores the factory calibration. Writing is off per gateway by default; request it for the gateway in the portal.

Can I plug the GrowNET cable into the network port of the Gateway?

No. GrowNET uses RJ45 plugs but it is not Ethernet. Connect the sensor to the LX2 ModLINK and wire the LX2 to the RS485 terminals of the ModbusCloud Gateway.