Agrowtek Modbus templates
All 18 available Agrowtek templates for ModbusCloud.
Monitor Agrowtek cultivation controllers, fertigation systems and sensors over Modbus in your portal.
- Templates
- 18
- Connection
- Modbus RTU and TCP
- Registers
- 10 to 106 per template
- Compatible models
- ADi series (1, 2, 4, 5 or 6 heads) · ADi-XL series · BDX BatchMATIC · DXIO · DXI8 · DXO8 · DXR6 · DXV4 · DXC4 · GCX · GCX+ · GrowNET devices on a GCX: SXC, SXE, SXW, SXH, PHX, RD8i, VXi, ADi, DXI8 and others · HXT · HXT+ · HXG · LXD · PHX · PHXM · PHX+ · Agrowtek PHX and PHX+ hydroponics sensor transmitter, temperature and pH (+ORP or DO) · RD8i · RD8i+ · RX4i · RX1i · SXC · SXE · Agrowtek GrowControl SXE climate sensor and data logger with LCD display · SXG · Agrowtek SXG CO2 gas sensor · SXH · SXH+ · SXO2 · Agrowtek SXO2 dissolved oxygen transmitter and data logger with ODO probe · Agrowtek SXQ Quantum Light Sensor & Spectrometer · SXW · VX8i · VX12i
- Last updated
Agrowtek templates
15 via Modbus RTU, 3 via Modbus TCP
Agrowtek ADi Dosing PumpPeristaltic dosing pump with up to six heads for nutrients and pH correction.Modbus RTU25 read, 14 write
Agrowtek BDX Fertigation SystemBatch fertigation system that mixes nutrients to EC and pH targets and feeds up to 14 zones.Modbus TCP105 read, 34 write
Agrowtek DX Series I/O ModuleDIN-rail I/O modules for sensors, relays and analog outputs in grow rooms.Modbus RTU45 read, 16 write
Agrowtek GCX ControllerCultivation controller that shares the values of each connected sensor, relay and pump over Modbus TCP.Modbus TCP57 read, 31 write
Agrowtek GCX Dosing RecipesDosing recipe set points of the Agrowtek GCX controller over Modbus TCP.Modbus TCP21 read, 15 write
Agrowtek HXT Moisture HubHub for eight substrate sensors with water content, EC and temperature per port.Modbus RTU30 read, 1 write
Agrowtek LXD DigiLINKBrightness and spectrum control for digital LED grow lights.Modbus RTU16 read, 11 write
Agrowtek PHX pH SensorpH and temperature transmitter for nutrient solution, with ORP or oxygen on the PHX+.Modbus RTU14 read, 11 write
Agrowtek RD8i Relay ModuleEight-channel dry-contact relay module for lighting, ventilation, irrigation and HVAC.Modbus RTU23 read, 10 write
Agrowtek RX4i Outlet RelaySwitched outlet relay with four or one receptacle and closure counters.Modbus RTU15 read, 6 write
Agrowtek SXC Climate SensorCanopy climate sensor for temperature, humidity, PPFD light, CO2 and leaf temperature.Modbus RTU17 read, 13 write
Agrowtek SXE Environment SensorClimate sensor with display for drying and grow rooms: temperature, humidity, light and CO2.Modbus RTU16 read, 12 write
Agrowtek SXG CO2 SensorNDIR CO2 gas sensor for CO2 alarm monitoring up to 40,000 ppm in grow rooms and plant rooms.Modbus RTU8 read, 3 write
Agrowtek SXH Hydroponics SensorWater sensor transmitter for nutrient solution temperature, pH, EC and ORP or dissolved oxygen.Modbus RTU14 read, 15 writeAgrowtek SXO2 Dissolved Oxygen SensorOptical dissolved oxygen transmitter for nutrient tanks and hydroponics: oxygen and water temperature.Modbus RTU10 read, 7 write
Agrowtek SXQ Quantum Light SensorLight sensor and spectrometer for greenhouses and indoor farms, with lux, color temperature and spectrum.Modbus RTU22 read, 1 write
Agrowtek SXW Weather StationOutdoor weather station for temperature, humidity, irradiance, wind, rain and CO2.Modbus RTU21 read, 15 write
Agrowtek VXi Irrigation Valve ControllerIrrigation valve controller with eight 24 V outputs and four analog inputs on the VX12i.Modbus RTU31 read, 10 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

Agrowtek builds controllers, dosing pumps and sensors for greenhouses and indoor cultivation: the GCX controller, the BDX fertigation system and sensors for climate, CO2, light and water.
The GCX shares its values over Modbus TCP, and the sensors and modules connect over Modbus RTU on RS485. The gateway reads both. In the portal you follow EC, pH, climate and valves per zone, and you can set an alarm on any value.
What you can read out
- EC, pH and water temperature
- Air temperature, humidity and CO2
- Light level and leaf temperature
- Valve and pump states per zone
Typical installations
- Greenhouses with fertigation per irrigation zone
- Indoor cultivation rooms with climate and CO2 control
Want to see how it works?