Agrowtek Agrowtek SXH Hydroponics Sensor Modbus RTU template

Agrowtek SXH Hydroponics Sensor

Water sensor transmitter for nutrient solution temperature, pH, EC and ORP or dissolved oxygen.

The Agrowtek SXH is a hydroponics sensor transmitter that measures temperature, pH, electrical conductivity and, on the SXH+, ORP or dissolved oxygen of the nutrient solution in greenhouse and indoor fertigation. This Modbus RTU template reads all water values and identification through the LX2 ModLINK, and lets you run zero and span calibration and change units from ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 19200 baud
Registers
28, read and write
Key readings
Solution temperature · pH · Electrical conductivity · ORP or dissolved oxygen
Available commands
Zero calibration · Span calibration · Analog output calibration · Measurement units
Compatible models
SXH · SXH+
Last updated

Registers (28)

14 read, 15 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Temperature°CRead
pHpHRead
ConductivityµS/cmRead
ORP / DO / FlowRead
Temperature Float°CRead
pH FloatpHRead
Conductivity FloatµS/cmRead
ORP / DO / Flow FloatRead
Toggle UnitsWrite
Temperature Zero Calibration°CWrite
pH Zero CalibrationpHWrite
Conductivity Zero CalibrationµS/cmWrite
ORP / DO / Flow Zero CalibrationWrite
Temperature Span Calibration°CWrite
pH Span CalibrationpHWrite
Conductivity Span CalibrationµS/cmWrite
ORP / DO / Flow Span CalibrationWrite
Temperature Analog Output CalibrationWrite
pH Analog Output CalibrationWrite
Conductivity Analog Output CalibrationWrite
ORP / DO / Flow Analog Output CalibrationWrite
Clear CalibrationWrite
Device AddressRead and write
Serial NumberRead
Date of ManufactureRead
Hardware VersionRead
Firmware VersionRead
Device ModelRead

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Show pH, EC and solution temperature of each nutrient tank on one ModbusCloud dashboard.
  • Get an email or webhook when pH or EC leaves the band you set, with one rule for each limit.
  • Compare EC of supply water and drain water from two sensors over 365 days of history.
  • Catch a fouled pH probe with the automatic monitoring, which reports a value that stays exactly the same for hours.
  • Run pH 7 and pH 4.01 calibration from the portal by writing the buffer values to the zero and span registers.

Installation

  1. Mount the SXH near the tank or line and fit the pH, EC and temperature probes and, on the SXH+, the ORP or DO probe. Keep pH and ORP tips wet.

  2. Connect the GrowNET port to an Agrowtek LX2 ModLINK, directly or through an HX8 hub, and wire TX/RX+ and TX/RX- of the LX2 to the RS485 terminals of the ModbusCloud Gateway. Terminate the bus.

  3. Give the transmitter its own address from 1 to 247 in its setup menu or with the AgrowLINK utility.

  4. In ModbusCloud, add a Modbus device with protocol RTU, the address, 19200 baud, 8 data bits, no parity and 1 stop bit, and import this template.

  5. Check pH and EC against a buffer or reference solution before you rely on alarms.

Things to watch for

The SXH does not answer through the LX2. What should I check?

Check 19200 baud, no parity, 1 stop bit and the transmitter address in ModbusCloud; the LX2 may have been set to another speed with the ModLINK utility. Swap TX/RX+ and TX/RX- if nothing comes back, terminate the RS485 bus, and give every GrowNET device behind the LX2 its own address.

EC reads about half of what I expect. Why?

The conductivity channel is probably set to ppm instead of microsiemens; on the SXH scale 2500 ppm matches 5000 µS. Change the EC units in the transmitter menu or write 3, the channel number of conductivity, to Toggle Units.

What does the fourth value mean on my SXH?

It carries ORP in mV on an SXH+ with an ORP probe, or dissolved oxygen with a DO probe. The scaled value is mV as is, or mg/L times 100 for DO. The floating-point value shows the reading directly, so use that one if you are not sure which probe is fitted.

How do I calibrate pH from ModbusCloud?

With the probe in pH 7 buffer, write 7.00 to pH Zero Calibration; then in pH 4.01 buffer write 4.01 to pH Span Calibration. Always zero before span. For EC write 1413 to the span register in a 1413 µS standard. Writing is off per gateway by default; request it for the gateway in the portal.

Can I plug the GrowNET cable into the network port of the Gateway?

No. GrowNET uses RJ45 plugs but it is not Ethernet. Connect the SXH to the LX2 ModLINK and wire the LX2 to the RS485 terminals of the ModbusCloud Gateway.

Want to see how it works?