Circutor CVM-B100 / CVM-B150 Tariffs and Max/Min Values

Tariff energy counters and recorded peaks of a panel power analyzer.

The Circutor CVM-B100 and CVM-B150 are panel power analyzers that count energy in three tariffs and record the highest and lowest value of every electrical quantity. This Modbus RTU template reads the energy per tariff and all maximum and minimum values with their date and time into ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 19200 baud
Registers
476, read only
Key readings
Energy per tariff · Maximum voltage · Maximum current · Maximum power · Minimum power factor
Compatible models
CVM-B100 · CVM-B150
Last updated

Registers (476)

476 read, 0 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Phase Voltage L1 MaximumRead256FC04int32
Phase Voltage L1 Maximum TimeRead258FC04uint32
Phase Voltage L1 MinimumRead768FC04int32
Phase Voltage L1 Minimum TimeRead770FC04uint32
Current L1 MaximumRead260FC04int32
Current L1 Maximum TimeRead
Current L1 MinimumRead
Current L1 Minimum TimeRead
Active Power L1 MaximumRead
Active Power L1 Maximum TimeRead
Active Power L1 MinimumRead
Active Power L1 Minimum TimeRead
Inductive Reactive Power L1 MaximumRead
Inductive Reactive Power L1 Maximum TimeRead
Inductive Reactive Power L1 MinimumRead
Inductive Reactive Power L1 Minimum TimeRead
Capacitive Reactive Power L1 MaximumRead
Capacitive Reactive Power L1 Maximum TimeRead
Capacitive Reactive Power L1 MinimumRead
Capacitive Reactive Power L1 Minimum TimeRead
Apparent Power L1 MaximumRead
Apparent Power L1 Maximum TimeRead
Apparent Power L1 MinimumRead
Apparent Power L1 Minimum TimeRead
Power Factor L1 MaximumRead
Power Factor L1 Maximum TimeRead
Power Factor L1 MinimumRead
Power Factor L1 Minimum TimeRead
Cos Phi L1 MaximumRead
Cos Phi L1 Maximum TimeRead
Cos Phi L1 MinimumRead
Cos Phi L1 Minimum TimeRead
Phase Voltage L2 MaximumRead
Phase Voltage L2 Maximum TimeRead
Phase Voltage L2 MinimumRead
Phase Voltage L2 Minimum TimeRead
Current L2 MaximumRead
Current L2 Maximum TimeRead
Current L2 MinimumRead
Current L2 Minimum TimeRead
Active Power L2 MaximumRead
Active Power L2 Maximum TimeRead
Active Power L2 MinimumRead
Active Power L2 Minimum TimeRead
Inductive Reactive Power L2 MaximumRead
Inductive Reactive Power L2 Maximum TimeRead
Inductive Reactive Power L2 MinimumRead
Inductive Reactive Power L2 Minimum TimeRead
Capacitive Reactive Power L2 MaximumRead
Capacitive Reactive Power L2 Maximum TimeRead
Capacitive Reactive Power L2 MinimumRead
Capacitive Reactive Power L2 Minimum TimeRead
Apparent Power L2 MaximumRead
Apparent Power L2 Maximum TimeRead
Apparent Power L2 MinimumRead
Apparent Power L2 Minimum TimeRead
Power Factor L2 MaximumRead
Power Factor L2 Maximum TimeRead
Power Factor L2 MinimumRead
Power Factor L2 Minimum TimeRead
Cos Phi L2 MaximumRead
Cos Phi L2 Maximum TimeRead
Cos Phi L2 MinimumRead
Cos Phi L2 Minimum TimeRead
Phase Voltage L3 MaximumRead
Phase Voltage L3 Maximum TimeRead
Phase Voltage L3 MinimumRead
Phase Voltage L3 Minimum TimeRead
Current L3 MaximumRead
Current L3 Maximum TimeRead
Current L3 MinimumRead
Current L3 Minimum TimeRead
Active Power L3 MaximumRead
Active Power L3 Maximum TimeRead
Active Power L3 MinimumRead
Active Power L3 Minimum TimeRead
Inductive Reactive Power L3 MaximumRead
Inductive Reactive Power L3 Maximum TimeRead
Inductive Reactive Power L3 MinimumRead
Inductive Reactive Power L3 Minimum TimeRead
Capacitive Reactive Power L3 MaximumRead
Capacitive Reactive Power L3 Maximum TimeRead
Capacitive Reactive Power L3 MinimumRead
Capacitive Reactive Power L3 Minimum TimeRead
Apparent Power L3 MaximumRead
Apparent Power L3 Maximum TimeRead
Apparent Power L3 MinimumRead
Apparent Power L3 Minimum TimeRead
Power Factor L3 MaximumRead
Power Factor L3 Maximum TimeRead
Power Factor L3 MinimumRead
Power Factor L3 Minimum TimeRead
Cos Phi L3 MaximumRead
Cos Phi L3 Maximum TimeRead
Cos Phi L3 MinimumRead
Cos Phi L3 Minimum TimeRead
Neutral Voltage MaximumRead
Neutral Voltage Maximum TimeRead
Neutral Voltage MinimumRead
Neutral Voltage Minimum TimeRead
Neutral Current MaximumRead
Neutral Current Maximum TimeRead
Neutral Current MinimumRead
Neutral Current Minimum TimeRead
Frequency L1 MaximumRead
Frequency L1 Maximum TimeRead
Frequency L1 MinimumRead
Frequency L1 Minimum TimeRead
Voltage L1-L2 MaximumRead
Voltage L1-L2 Maximum TimeRead
Voltage L1-L2 MinimumRead
Voltage L1-L2 Minimum TimeRead
Voltage L2-L3 MaximumRead
Voltage L2-L3 Maximum TimeRead
Voltage L2-L3 MinimumRead
Voltage L2-L3 Minimum TimeRead
Voltage L3-L1 MaximumRead
Voltage L3-L1 Maximum TimeRead
Voltage L3-L1 MinimumRead
Voltage L3-L1 Minimum TimeRead
Three-Phase Line Voltage MaximumRead
Three-Phase Line Voltage Maximum TimeRead
Three-Phase Line Voltage MinimumRead
Three-Phase Line Voltage Minimum TimeRead
Three-Phase Phase Voltage MaximumRead
Three-Phase Phase Voltage Maximum TimeRead
Three-Phase Phase Voltage MinimumRead
Three-Phase Phase Voltage Minimum TimeRead
Three-Phase Current MaximumRead
Three-Phase Current Maximum TimeRead
Three-Phase Current MinimumRead
Three-Phase Current Minimum TimeRead
Three-Phase Active Power MaximumRead
Three-Phase Active Power Maximum TimeRead
Three-Phase Active Power MinimumRead
Three-Phase Active Power Minimum TimeRead
Three-Phase Inductive Reactive Power MaximumRead
Three-Phase Inductive Reactive Power Maximum TimeRead
Three-Phase Inductive Reactive Power MinimumRead
Three-Phase Inductive Reactive Power Minimum TimeRead
Three-Phase Capacitive Reactive Power MaximumRead
Three-Phase Capacitive Reactive Power Maximum TimeRead
Three-Phase Capacitive Reactive Power MinimumRead
Three-Phase Capacitive Reactive Power Minimum TimeRead
Three-Phase Apparent Power MaximumRead
Three-Phase Apparent Power Maximum TimeRead
Three-Phase Apparent Power MinimumRead
Three-Phase Apparent Power Minimum TimeRead
Three-Phase Power Factor MaximumRead
Three-Phase Power Factor Maximum TimeRead
Three-Phase Power Factor MinimumRead
Three-Phase Power Factor Minimum TimeRead
Three-Phase Cos Phi MaximumRead
Three-Phase Cos Phi Maximum TimeRead
Three-Phase Cos Phi MinimumRead
Three-Phase Cos Phi Minimum TimeRead
Voltage THD L1 MaximumRead
Voltage THD L1 Maximum TimeRead
Voltage THD L1 MinimumRead
Voltage THD L1 Minimum TimeRead
Voltage THD L2 MaximumRead
Voltage THD L2 Maximum TimeRead
Voltage THD L2 MinimumRead
Voltage THD L2 Minimum TimeRead
Voltage THD L3 MaximumRead
Voltage THD L3 Maximum TimeRead
Voltage THD L3 MinimumRead
Voltage THD L3 Minimum TimeRead
Voltage THD Neutral MaximumRead
Voltage THD Neutral Maximum TimeRead
Voltage THD Neutral MinimumRead
Voltage THD Neutral Minimum TimeRead
Current THD L1 MaximumRead
Current THD L1 Maximum TimeRead
Current THD L1 MinimumRead
Current THD L1 Minimum TimeRead
Current THD L2 MaximumRead
Current THD L2 Maximum TimeRead
Current THD L2 MinimumRead
Current THD L2 Minimum TimeRead
Current THD L3 MaximumRead
Current THD L3 Maximum TimeRead
Current THD L3 MinimumRead
Current THD L3 Minimum TimeRead
Current THD Neutral MaximumRead
Current THD Neutral Maximum TimeRead
Current THD Neutral MinimumRead
Current THD Neutral Minimum TimeRead
Reactive Power L1 MaximumRead
Reactive Power L1 Maximum TimeRead
Reactive Power L1 MinimumRead
Reactive Power L1 Minimum TimeRead
Reactive Power L2 MaximumRead
Reactive Power L2 Maximum TimeRead
Reactive Power L2 MinimumRead
Reactive Power L2 Minimum TimeRead
Reactive Power L3 MaximumRead
Reactive Power L3 Maximum TimeRead
Reactive Power L3 MinimumRead
Reactive Power L3 Minimum TimeRead
Three-Phase Reactive Power MaximumRead
Three-Phase Reactive Power Maximum TimeRead
Three-Phase Reactive Power MinimumRead
Three-Phase Reactive Power Minimum TimeRead
Reactive Power Consumed L1 MaximumRead
Reactive Power Consumed L1 Maximum TimeRead
Reactive Power Consumed L1 MinimumRead
Reactive Power Consumed L1 Minimum TimeRead
Reactive Power Consumed L2 MaximumRead
Reactive Power Consumed L2 Maximum TimeRead
Reactive Power Consumed L2 MinimumRead
Reactive Power Consumed L2 Minimum TimeRead
Reactive Power Consumed L3 MaximumRead
Reactive Power Consumed L3 Maximum TimeRead
Reactive Power Consumed L3 MinimumRead
Reactive Power Consumed L3 Minimum TimeRead
Three-Phase Reactive Power Consumed MaximumRead
Three-Phase Reactive Power Consumed Maximum TimeRead
Three-Phase Reactive Power Consumed MinimumRead
Three-Phase Reactive Power Consumed Minimum TimeRead
Reactive Power Generated L1 MaximumRead
Reactive Power Generated L1 Maximum TimeRead
Reactive Power Generated L1 MinimumRead
Reactive Power Generated L1 Minimum TimeRead
Reactive Power Generated L2 MaximumRead
Reactive Power Generated L2 Maximum TimeRead
Reactive Power Generated L2 MinimumRead
Reactive Power Generated L2 Minimum TimeRead
Reactive Power Generated L3 MaximumRead
Reactive Power Generated L3 Maximum TimeRead
Reactive Power Generated L3 MinimumRead
Reactive Power Generated L3 Minimum TimeRead
Three-Phase Reactive Power Generated MaximumRead
Three-Phase Reactive Power Generated Maximum TimeRead
Three-Phase Reactive Power Generated MinimumRead
Three-Phase Reactive Power Generated Minimum TimeRead
Tariff 1 Active Energy Consumed L1kWhRead
Tariff 1 Active Energy Consumed L1 DecimalWhRead
Tariff 1 Active Energy Consumed L2kWhRead
Tariff 1 Active Energy Consumed L2 DecimalWhRead
Tariff 1 Active Energy Consumed L3kWhRead
Tariff 1 Active Energy Consumed L3 DecimalWhRead
Tariff 1 Active Energy Consumed 3-PhasekWhRead
Tariff 1 Active Energy Consumed 3-Phase DecimalWhRead
Tariff 1 Inductive Reactive Energy Consumed L1kvarhRead
Tariff 1 Inductive Reactive Energy Consumed L1 DecimalvarhRead
Tariff 1 Inductive Reactive Energy Consumed L2kvarhRead
Tariff 1 Inductive Reactive Energy Consumed L2 DecimalvarhRead
Tariff 1 Inductive Reactive Energy Consumed L3kvarhRead
Tariff 1 Inductive Reactive Energy Consumed L3 DecimalvarhRead
Tariff 1 Inductive Reactive Energy Consumed 3-PhasekvarhRead
Tariff 1 Inductive Reactive Energy Consumed 3-Phase DecimalvarhRead
Tariff 1 Capacitive Reactive Energy Consumed L1kvarhRead
Tariff 1 Capacitive Reactive Energy Consumed L1 DecimalvarhRead
Tariff 1 Capacitive Reactive Energy Consumed L2kvarhRead
Tariff 1 Capacitive Reactive Energy Consumed L2 DecimalvarhRead
Tariff 1 Capacitive Reactive Energy Consumed L3kvarhRead
Tariff 1 Capacitive Reactive Energy Consumed L3 DecimalvarhRead
Tariff 1 Capacitive Reactive Energy Consumed 3-PhasekvarhRead
Tariff 1 Capacitive Reactive Energy Consumed 3-Phase DecimalvarhRead
Tariff 1 Reactive Energy Consumed L1kvarhRead
Tariff 1 Reactive Energy Consumed L1 DecimalvarhRead
Tariff 1 Reactive Energy Consumed L2kvarhRead
Tariff 1 Reactive Energy Consumed L2 DecimalvarhRead
Tariff 1 Reactive Energy Consumed L3kvarhRead
Tariff 1 Reactive Energy Consumed L3 DecimalvarhRead
Tariff 1 Reactive Energy Consumed 3-PhasekvarhRead
Tariff 1 Reactive Energy Consumed 3-Phase DecimalvarhRead
Tariff 1 Apparent Energy Consumed L1kVAhRead
Tariff 1 Apparent Energy Consumed L1 DecimalVAhRead
Tariff 1 Apparent Energy Consumed L2kVAhRead
Tariff 1 Apparent Energy Consumed L2 DecimalVAhRead
Tariff 1 Apparent Energy Consumed L3kVAhRead
Tariff 1 Apparent Energy Consumed L3 DecimalVAhRead
Tariff 1 Apparent Energy Consumed 3-PhasekVAhRead
Tariff 1 Apparent Energy Consumed 3-Phase DecimalVAhRead
Tariff 1 Active Energy Generated L1kWhRead
Tariff 1 Active Energy Generated L1 DecimalWhRead
Tariff 1 Active Energy Generated L2kWhRead
Tariff 1 Active Energy Generated L2 DecimalWhRead
Tariff 1 Active Energy Generated L3kWhRead
Tariff 1 Active Energy Generated L3 DecimalWhRead
Tariff 1 Active Energy Generated 3-PhasekWhRead
Tariff 1 Active Energy Generated 3-Phase DecimalWhRead
Tariff 1 Inductive Reactive Energy Generated L1kvarhRead
Tariff 1 Inductive Reactive Energy Generated L1 DecimalvarhRead
Tariff 1 Inductive Reactive Energy Generated L2kvarhRead
Tariff 1 Inductive Reactive Energy Generated L2 DecimalvarhRead
Tariff 1 Inductive Reactive Energy Generated L3kvarhRead
Tariff 1 Inductive Reactive Energy Generated L3 DecimalvarhRead
Tariff 1 Inductive Reactive Energy Generated 3-PhasekvarhRead
Tariff 1 Inductive Reactive Energy Generated 3-Phase DecimalvarhRead
Tariff 1 Capacitive Reactive Energy Generated L1kvarhRead
Tariff 1 Capacitive Reactive Energy Generated L1 DecimalvarhRead
Tariff 1 Capacitive Reactive Energy Generated L2kvarhRead
Tariff 1 Capacitive Reactive Energy Generated L2 DecimalvarhRead
Tariff 1 Capacitive Reactive Energy Generated L3kvarhRead
Tariff 1 Capacitive Reactive Energy Generated L3 DecimalvarhRead
Tariff 1 Capacitive Reactive Energy Generated 3-PhasekvarhRead
Tariff 1 Capacitive Reactive Energy Generated 3-Phase DecimalvarhRead
Tariff 1 Reactive Energy Generated L1kvarhRead
Tariff 1 Reactive Energy Generated L1 DecimalvarhRead
Tariff 1 Reactive Energy Generated L2kvarhRead
Tariff 1 Reactive Energy Generated L2 DecimalvarhRead
Tariff 1 Reactive Energy Generated L3kvarhRead
Tariff 1 Reactive Energy Generated L3 DecimalvarhRead
Tariff 1 Reactive Energy Generated 3-PhasekvarhRead
Tariff 1 Reactive Energy Generated 3-Phase DecimalvarhRead
Tariff 1 Apparent Energy Generated L1kVAhRead
Tariff 1 Apparent Energy Generated L1 DecimalVAhRead
Tariff 1 Apparent Energy Generated L2kVAhRead
Tariff 1 Apparent Energy Generated L2 DecimalVAhRead
Tariff 1 Apparent Energy Generated L3kVAhRead
Tariff 1 Apparent Energy Generated L3 DecimalVAhRead
Tariff 1 Apparent Energy Generated 3-PhasekVAhRead
Tariff 1 Apparent Energy Generated 3-Phase DecimalVAhRead
Tariff 2 Active Energy Consumed L1kWhRead
Tariff 2 Active Energy Consumed L1 DecimalWhRead
Tariff 2 Active Energy Consumed L2kWhRead
Tariff 2 Active Energy Consumed L2 DecimalWhRead
Tariff 2 Active Energy Consumed L3kWhRead
Tariff 2 Active Energy Consumed L3 DecimalWhRead
Tariff 2 Active Energy Consumed 3-PhasekWhRead
Tariff 2 Active Energy Consumed 3-Phase DecimalWhRead
Tariff 2 Inductive Reactive Energy Consumed L1kvarhRead
Tariff 2 Inductive Reactive Energy Consumed L1 DecimalvarhRead
Tariff 2 Inductive Reactive Energy Consumed L2kvarhRead
Tariff 2 Inductive Reactive Energy Consumed L2 DecimalvarhRead
Tariff 2 Inductive Reactive Energy Consumed L3kvarhRead
Tariff 2 Inductive Reactive Energy Consumed L3 DecimalvarhRead
Tariff 2 Inductive Reactive Energy Consumed 3-PhasekvarhRead
Tariff 2 Inductive Reactive Energy Consumed 3-Phase DecimalvarhRead
Tariff 2 Capacitive Reactive Energy Consumed L1kvarhRead
Tariff 2 Capacitive Reactive Energy Consumed L1 DecimalvarhRead
Tariff 2 Capacitive Reactive Energy Consumed L2kvarhRead
Tariff 2 Capacitive Reactive Energy Consumed L2 DecimalvarhRead
Tariff 2 Capacitive Reactive Energy Consumed L3kvarhRead
Tariff 2 Capacitive Reactive Energy Consumed L3 DecimalvarhRead
Tariff 2 Capacitive Reactive Energy Consumed 3-PhasekvarhRead
Tariff 2 Capacitive Reactive Energy Consumed 3-Phase DecimalvarhRead
Tariff 2 Reactive Energy Consumed L1kvarhRead
Tariff 2 Reactive Energy Consumed L1 DecimalvarhRead
Tariff 2 Reactive Energy Consumed L2kvarhRead
Tariff 2 Reactive Energy Consumed L2 DecimalvarhRead
Tariff 2 Reactive Energy Consumed L3kvarhRead
Tariff 2 Reactive Energy Consumed L3 DecimalvarhRead
Tariff 2 Reactive Energy Consumed 3-PhasekvarhRead
Tariff 2 Reactive Energy Consumed 3-Phase DecimalvarhRead
Tariff 2 Apparent Energy Consumed L1kVAhRead
Tariff 2 Apparent Energy Consumed L1 DecimalVAhRead
Tariff 2 Apparent Energy Consumed L2kVAhRead
Tariff 2 Apparent Energy Consumed L2 DecimalVAhRead
Tariff 2 Apparent Energy Consumed L3kVAhRead
Tariff 2 Apparent Energy Consumed L3 DecimalVAhRead
Tariff 2 Apparent Energy Consumed 3-PhasekVAhRead
Tariff 2 Apparent Energy Consumed 3-Phase DecimalVAhRead
Tariff 2 Active Energy Generated L1kWhRead
Tariff 2 Active Energy Generated L1 DecimalWhRead
Tariff 2 Active Energy Generated L2kWhRead
Tariff 2 Active Energy Generated L2 DecimalWhRead
Tariff 2 Active Energy Generated L3kWhRead
Tariff 2 Active Energy Generated L3 DecimalWhRead
Tariff 2 Active Energy Generated 3-PhasekWhRead
Tariff 2 Active Energy Generated 3-Phase DecimalWhRead
Tariff 2 Inductive Reactive Energy Generated L1kvarhRead
Tariff 2 Inductive Reactive Energy Generated L1 DecimalvarhRead
Tariff 2 Inductive Reactive Energy Generated L2kvarhRead
Tariff 2 Inductive Reactive Energy Generated L2 DecimalvarhRead
Tariff 2 Inductive Reactive Energy Generated L3kvarhRead
Tariff 2 Inductive Reactive Energy Generated L3 DecimalvarhRead
Tariff 2 Inductive Reactive Energy Generated 3-PhasekvarhRead
Tariff 2 Inductive Reactive Energy Generated 3-Phase DecimalvarhRead
Tariff 2 Capacitive Reactive Energy Generated L1kvarhRead
Tariff 2 Capacitive Reactive Energy Generated L1 DecimalvarhRead
Tariff 2 Capacitive Reactive Energy Generated L2kvarhRead
Tariff 2 Capacitive Reactive Energy Generated L2 DecimalvarhRead
Tariff 2 Capacitive Reactive Energy Generated L3kvarhRead
Tariff 2 Capacitive Reactive Energy Generated L3 DecimalvarhRead
Tariff 2 Capacitive Reactive Energy Generated 3-PhasekvarhRead
Tariff 2 Capacitive Reactive Energy Generated 3-Phase DecimalvarhRead
Tariff 2 Reactive Energy Generated L1kvarhRead
Tariff 2 Reactive Energy Generated L1 DecimalvarhRead
Tariff 2 Reactive Energy Generated L2kvarhRead
Tariff 2 Reactive Energy Generated L2 DecimalvarhRead
Tariff 2 Reactive Energy Generated L3kvarhRead
Tariff 2 Reactive Energy Generated L3 DecimalvarhRead
Tariff 2 Reactive Energy Generated 3-PhasekvarhRead
Tariff 2 Reactive Energy Generated 3-Phase DecimalvarhRead
Tariff 2 Apparent Energy Generated L1kVAhRead
Tariff 2 Apparent Energy Generated L1 DecimalVAhRead
Tariff 2 Apparent Energy Generated L2kVAhRead
Tariff 2 Apparent Energy Generated L2 DecimalVAhRead
Tariff 2 Apparent Energy Generated L3kVAhRead
Tariff 2 Apparent Energy Generated L3 DecimalVAhRead
Tariff 2 Apparent Energy Generated 3-PhasekVAhRead
Tariff 2 Apparent Energy Generated 3-Phase DecimalVAhRead
Tariff 3 Active Energy Consumed L1kWhRead
Tariff 3 Active Energy Consumed L1 DecimalWhRead
Tariff 3 Active Energy Consumed L2kWhRead
Tariff 3 Active Energy Consumed L2 DecimalWhRead
Tariff 3 Active Energy Consumed L3kWhRead
Tariff 3 Active Energy Consumed L3 DecimalWhRead
Tariff 3 Active Energy Consumed 3-PhasekWhRead
Tariff 3 Active Energy Consumed 3-Phase DecimalWhRead
Tariff 3 Inductive Reactive Energy Consumed L1kvarhRead
Tariff 3 Inductive Reactive Energy Consumed L1 DecimalvarhRead
Tariff 3 Inductive Reactive Energy Consumed L2kvarhRead
Tariff 3 Inductive Reactive Energy Consumed L2 DecimalvarhRead
Tariff 3 Inductive Reactive Energy Consumed L3kvarhRead
Tariff 3 Inductive Reactive Energy Consumed L3 DecimalvarhRead
Tariff 3 Inductive Reactive Energy Consumed 3-PhasekvarhRead
Tariff 3 Inductive Reactive Energy Consumed 3-Phase DecimalvarhRead
Tariff 3 Capacitive Reactive Energy Consumed L1kvarhRead
Tariff 3 Capacitive Reactive Energy Consumed L1 DecimalvarhRead
Tariff 3 Capacitive Reactive Energy Consumed L2kvarhRead
Tariff 3 Capacitive Reactive Energy Consumed L2 DecimalvarhRead
Tariff 3 Capacitive Reactive Energy Consumed L3kvarhRead
Tariff 3 Capacitive Reactive Energy Consumed L3 DecimalvarhRead
Tariff 3 Capacitive Reactive Energy Consumed 3-PhasekvarhRead
Tariff 3 Capacitive Reactive Energy Consumed 3-Phase DecimalvarhRead
Tariff 3 Reactive Energy Consumed L1kvarhRead
Tariff 3 Reactive Energy Consumed L1 DecimalvarhRead
Tariff 3 Reactive Energy Consumed L2kvarhRead
Tariff 3 Reactive Energy Consumed L2 DecimalvarhRead
Tariff 3 Reactive Energy Consumed L3kvarhRead
Tariff 3 Reactive Energy Consumed L3 DecimalvarhRead
Tariff 3 Reactive Energy Consumed 3-PhasekvarhRead
Tariff 3 Reactive Energy Consumed 3-Phase DecimalvarhRead
Tariff 3 Apparent Energy Consumed L1kVAhRead
Tariff 3 Apparent Energy Consumed L1 DecimalVAhRead
Tariff 3 Apparent Energy Consumed L2kVAhRead
Tariff 3 Apparent Energy Consumed L2 DecimalVAhRead
Tariff 3 Apparent Energy Consumed L3kVAhRead
Tariff 3 Apparent Energy Consumed L3 DecimalVAhRead
Tariff 3 Apparent Energy Consumed 3-PhasekVAhRead
Tariff 3 Apparent Energy Consumed 3-Phase DecimalVAhRead
Tariff 3 Active Energy Generated L1kWhRead
Tariff 3 Active Energy Generated L1 DecimalWhRead
Tariff 3 Active Energy Generated L2kWhRead
Tariff 3 Active Energy Generated L2 DecimalWhRead
Tariff 3 Active Energy Generated L3kWhRead
Tariff 3 Active Energy Generated L3 DecimalWhRead
Tariff 3 Active Energy Generated 3-PhasekWhRead
Tariff 3 Active Energy Generated 3-Phase DecimalWhRead
Tariff 3 Inductive Reactive Energy Generated L1kvarhRead
Tariff 3 Inductive Reactive Energy Generated L1 DecimalvarhRead
Tariff 3 Inductive Reactive Energy Generated L2kvarhRead
Tariff 3 Inductive Reactive Energy Generated L2 DecimalvarhRead
Tariff 3 Inductive Reactive Energy Generated L3kvarhRead
Tariff 3 Inductive Reactive Energy Generated L3 DecimalvarhRead
Tariff 3 Inductive Reactive Energy Generated 3-PhasekvarhRead
Tariff 3 Inductive Reactive Energy Generated 3-Phase DecimalvarhRead
Tariff 3 Capacitive Reactive Energy Generated L1kvarhRead
Tariff 3 Capacitive Reactive Energy Generated L1 DecimalvarhRead
Tariff 3 Capacitive Reactive Energy Generated L2kvarhRead
Tariff 3 Capacitive Reactive Energy Generated L2 DecimalvarhRead
Tariff 3 Capacitive Reactive Energy Generated L3kvarhRead
Tariff 3 Capacitive Reactive Energy Generated L3 DecimalvarhRead
Tariff 3 Capacitive Reactive Energy Generated 3-PhasekvarhRead
Tariff 3 Capacitive Reactive Energy Generated 3-Phase DecimalvarhRead
Tariff 3 Reactive Energy Generated L1kvarhRead
Tariff 3 Reactive Energy Generated L1 DecimalvarhRead
Tariff 3 Reactive Energy Generated L2kvarhRead
Tariff 3 Reactive Energy Generated L2 DecimalvarhRead
Tariff 3 Reactive Energy Generated L3kvarhRead
Tariff 3 Reactive Energy Generated L3 DecimalvarhRead
Tariff 3 Reactive Energy Generated 3-PhasekvarhRead
Tariff 3 Reactive Energy Generated 3-Phase DecimalvarhRead
Tariff 3 Apparent Energy Generated L1kVAhRead
Tariff 3 Apparent Energy Generated L1 DecimalVAhRead
Tariff 3 Apparent Energy Generated L2kVAhRead
Tariff 3 Apparent Energy Generated L2 DecimalVAhRead
Tariff 3 Apparent Energy Generated L3kVAhRead
Tariff 3 Apparent Energy Generated L3 DecimalVAhRead
Tariff 3 Apparent Energy Generated 3-PhasekVAhRead
Tariff 3 Apparent Energy Generated 3-Phase DecimalVAhRead

Loading registers…

The ModbusCloud Gateway, front at an angle, with the RS485 terminal and the antenna connectors

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Use cases

  • Report energy consumed in peak and off-peak tariff per month from ModbusCloud.
  • Check the highest current per phase to see how close a feeder gets to its rating.
  • Find the moment the lowest voltage occurred by reading the time stamp next to it.
  • Compare generated energy per tariff on a site with solar panels.
  • Keep a history of the recorded maximum power for capacity planning.

Installation

  1. Wire and set up the analyzer as for the main CVM-B100 / CVM-B150 template.

  2. Set the tariff selection on the digital inputs of the analyzer if you use more than one tariff.

  3. In ModbusCloud, add a Modbus device (RTU) with the address and serial settings of the analyzer and import this template.

  4. Read Power and Energy Units from the main template once and set the scale of the energy and power registers to match.

  5. Check that Tariff 1 Active Energy Consumed 3-Phase shows a plausible counter.

Things to watch for

Why do tariff 2 and tariff 3 stay at zero?

The analyzer only counts in another tariff when a digital input is set to tariff selection and switches it. Without that, everything is counted in tariff 1 and in the totals of the main template.

How do I read the time stamp of a maximum?

The time stamp is one 32-bit number with the year (from 2013), month, day, hour, minute and second packed into bits. Show it as a raw number or decode it in your own software; the value itself is in the register before it.

The maximum values reset to zero. Why?

Maximum and minimum values are cleared by the reset command in the main template and from the menu of the analyzer. After a reset they start again from the next measurement.

Want to see how it works?