Schneider Electric Schneider Electric EasyLogic PM2200 Modbus RTU template

Schneider Electric EasyLogic PM2200

Three-phase panel meter for current, voltage, power, energy, demand and power quality.

The Schneider Electric EasyLogic PM2200 is a three-phase panel power meter that measures current, voltage, power, energy and power quality in switchboards and distribution panels. This Modbus RTU template reads all measurements, energy counters, demand values, harmonics and the meter setup from ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 9600 baud
Registers
1087, read only
Key readings
Current per phase · Voltage L-L and L-N · Active power · Power factor · Frequency · Active energy · Peak demand · Voltage and current THD
Compatible models
PM2220 · PM2230
Last updated

Registers (1087)

1087 read, 0 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Meter NameRead
Meter ModelRead
ManufacturerRead
Product ID NumberRead
Hardware DetectedRead
Supported FeaturesRead
Manufacturing Unit IdRead
Serial NumberRead
Date of ManufactureRead
Hardware RevisionRead
Production History 01Read
Production History 02Read
Production History 03Read
Production History 04Read
Production History 05Read
Production History 06Read
Production History 07Read
Production History 08Read
Production History 09Read
Production History 10Read
Production History 11Read
Production History 12Read
Production History 13Read
Production History 14Read
Production History 15Read
Production History 16Read
Production History 17Read
Production History 18Read
Production History 19Read
Production History 20Read
ChecksumRead
Slot A Installed Option - Slot ARead
Slot A Serial NumberRead
Slot A Date of ManufactureRead
Slot A Hardware RevisionRead
Slot A FW VersionRead
OS Present Firmware Version (DLF Format) X.Y.TRead
OS Present Version X - MajorRead
OS Present Version Y - MinorRead
OS Present Version Z - QualityRead
OS Present Version T - Internal EvolutionsRead
OS Previous Firmware Version (DLF Format) X.Y.TRead
OS Previous Version X - MajorRead
OS Previous Version Y - MinorRead
OS Previous Version Z - QualityRead
OS Previous Version T - Internal EvolutionsRead
OS Date/Time of Last Firmware DownloadRead
Reset Module Present Firmware Version (DLF Format) X.Y.TRead
Reset Module Present Version X - MajorRead
Reset Module Present Version Y - MinorRead
Reset Module Present Version Z - QualityRead
Reset Module Present Version T - Internal EvolutionsRead
Reset Module Previous Firmware Version (DLF Format) X.Y.TRead
Reset Module Previous Version X - MajorRead
Reset Module Previous Version Y - MinorRead
Reset Module Previous Version Z - QualityRead
Reset Module Previous Version T - Internal EvolutionsRead
Reset Module Date/Time of Last Firmware DownloadRead
Language Pack Present Firmware Version (DLF Format) X.Y.TRead
Language Pack Present Version X - MajorRead
Language Pack Present Version Y - MinorRead
Language Pack Present Version Z - QualityRead
Language Pack Present Version T - Internal EvolutionsRead
Language Pack Previous Firmware Version (DLF Format) X.Y.TRead
Language Pack Previous Version X - MajorRead
Language Pack Previous Version Y - MinorRead
Language Pack Previous Version Z - QualityRead
Language Pack Previous Version T - Internal EvolutionsRead
Language Pack Date/Time of Last Firmware DownloadRead
Language Pack ChecksumRead
Language Pack Bridge Code VersionRead
Download - CRC of Last FW DownloadRead
Download - Flash Write FailureRead
Download - % CompleteRead
Download ModeRead
Last Unit Restart DateTimeRead
Number of Metering System RestartsRead
Number of Control Power FailuresRead
Date/Time of Last Control Power FailureRead
Duration of Last Control Power FailuresRead
Cause of Last Meter ResetRead
Present Date & Time (7 Register Format) YearRead
MonthRead
DaydRead
HourhRead
MinuteminRead
SecondsRead
MillisecondmsRead
Present Date & Time (4 Register Format) YearRead
Month & DayRead
Hour & MinuteRead
MillisecondsRead
Setup PasswordRead
Energy Reset PasswordRead
Demand Reset PasswordRead
Min/Max Reset PasswordRead
Diagnostics PasswordRead
Active Load TimersRead
Meter Operation TimersRead
Cycle CountRead
Number of PhasesRead
Number of WiresRead
Power System ConfigurationRead
Nominal FrequencyHzRead
Nominal VoltageVRead
Nominal CurrentARead
Nominal Power FactorRead
Normal Phase RotationRead
Number VTsRead
VT PrimaryVRead
VT SecondaryVRead
Number CTsRead
CT PrimaryARead
CT SecondaryARead
CT Location for 1 or 2 CT MeteringRead
VT Location for 1 or 2 VT MeteringRead
VT Connection TypeRead
Active Load Timer SetpointARead
Alarm / Energy LED ModeRead
Energy Output Pulse Mode (Pulse/KY) / Make per ChanRead
Energy Pulse DurationmsRead
Pulse Output 1 Energy ChannelRead
Pulse Output 1 Digital Output AssociationRead
Pulse Output 1 Pulse WeightRead
Pulse Output 2 Energy ChannelRead
Pulse Output 2 Digital Output AssociationRead
Pulse Output 2 Pulse WeightRead
Pulse Output 3 Energy ChannelRead
Pulse Output 3 Digital Output AssociationRead
Pulse Output 3 Pulse WeightRead
Rate 1 LabelRead
Rate 1 Energy ChannelRead
Rate 1 Factor per K__hRead
Rate 2 LabelRead
Rate 2 Energy ChannelRead
Rate 2 Factor per K__hRead
Snapshot TimeRead
Energy Overflow Scale SelectionRead
CT Sequence SelectionRead
CT ReverseRead
Alarm Bitmap Standard - 1 Second Group 1 ValidityRead
Alarm Bitmap Standard - 1 Second Group 1Read
Alarm Bitmap Standard - 1 Second Group 2 ValidityRead
Alarm Bitmap Standard - 1 Second Group 2Read
Alarm Bitmap Standard - 1 Second Group 3 ValidityRead
Alarm Bitmap Standard - 1 Second Group 3Read
Alarm Bitmap Unary ValidityRead
Alarm Bitmap UnaryRead
Alarm Bitmap Digital Group 1 ValidityRead
Alarm Bitmap Digital Group 1Read
Digital Input Status Validity - Option Slot ARead
Digital Input Status - Option Slot ARead
Digital Output Status Validity - Option Slot ARead
Digital Output Status - Option Slot ARead
Digital Output Status Validity - Option Slot BRead
Digital Output Status - Option Slot BRead
Permanent Active Energy Delivered (Into Load) FloatkWhRead
Permanent Active Energy Received (Out of Load) FloatkWhRead
Permanent Active Energy Delivered + Received FloatkWhRead
Permanent Active Energy Delivered - Received FloatkWhRead
Permanent Reactive Energy Delivered FloatkvarhRead
Permanent Reactive Energy Received FloatkvarhRead
Permanent Reactive Energy Delivered + Received FloatkvarhRead
Permanent Reactive Energy Delivered - Received FloatkvarhRead
Permanent Apparent Energy Delivered FloatkVAhRead
Permanent Apparent Energy Received FloatkVAhRead
Permanent Apparent Energy Delivered + Received FloatkVAhRead
Permanent Apparent Energy Delivered - Received FloatkVAhRead
Active Energy Delivered (Into Load) FloatkWhRead
Active Energy Received (Out of Load) FloatkWhRead
Active Energy Delivered + Received FloatkWhRead
Active Energy Delivered - Received FloatkWhRead
Reactive Energy Delivered FloatkvarhRead
Reactive Energy Received FloatkvarhRead
Reactive Energy Delivered + Received FloatkvarhRead
Reactive Energy Delivered - Received FloatkvarhRead
Apparent Energy Delivered FloatkVAhRead
Apparent Energy Received FloatkVAhRead
Apparent Energy Delivered + Received FloatkVAhRead
Apparent Energy Delivered - Received FloatkVAhRead
Reactive Energy in Quadrant I FloatkvarhRead
Reactive Energy in Quadrant II FloatkvarhRead
Reactive Energy in Quadrant III FloatkvarhRead
Reactive Energy in Quadrant IV FloatkvarhRead
Active Energy Delivered Phase A FloatkWhRead
Active Energy Delivered Phase B FloatkWhRead
Active Energy Delivered Phase C FloatkWhRead
Reactive Energy Delivered Phase A FloatkvarhRead
Reactive Energy Delivered Phase B FloatkvarhRead
Reactive Energy Delivered Phase C FloatkvarhRead
Apparent Energy Delivered Phase A FloatkVAhRead
Apparent Energy Delivered Phase B FloatkVAhRead
Apparent Energy Delivered Phase C FloatkVAhRead
Rate1 ValueRead
Rate 2 ValueRead
Current AARead
Current BARead
Current CARead
Current NARead
Current GARead
Current AvgARead
Current Unbalance A%Read
Current Unbalance B%Read
Current Unbalance C%Read
Current Unbalance Worst%Read
Voltage A-BVRead
Voltage B-CVRead
Voltage C-AVRead
Voltage L-L AvgVRead
Voltage A-NVRead
Voltage B-NVRead
Voltage C-NVRead
Voltage L-N AvgVRead
Voltage Unbalance A-B%Read
Voltage Unbalance B-C%Read
Voltage Unbalance C-A%Read
Voltage Unbalance L-L Worst%Read
Voltage Unbalance A-N%Read
Voltage Unbalance B-N%Read
Voltage Unbalance C-N%Read
Voltage Unbalance L-N Worst%Read
Active Power AkWRead
Active Power BkWRead
Active Power CkWRead
Active Power TotalkWRead
Reactive Power AkvarRead
Reactive Power BkvarRead
Reactive Power CkvarRead
Reactive Power TotalkvarRead
Apparent Power AkVARead
Apparent Power BkVARead
Apparent Power CkVARead
Apparent Power TotalkVARead
Power Factor ARead
Power Factor BRead
Power Factor CRead
Power Factor TotalRead
Displacement Power Factor ARead
Displacement Power Factor BRead
Displacement Power Factor CRead
Displacement Power Factor TotalRead
FrequencyHzRead
Power Factor Total IEC FloatRead
Power Factor Total IEEE FloatRead
Power Factor Total IEC IntRead
Power Factor Total IEEE IntRead
Accumulated Energy Reset Date/TimeRead
Active Energy Delivered (Into Load)WhRead
Active Energy Received (Out of Load)WhRead
Active Energy Delivered + ReceivedWhRead
Active Energy Delivered - ReceivedWhRead
Reactive Energy DeliveredvarhRead
Reactive Energy ReceivedvarhRead
Reactive Energy Delivered + ReceivedvarhRead
Reactive Energy Delivered - ReceivedvarhRead
Apparent Energy DeliveredVAhRead
Apparent Energy ReceivedVAhRead
Apparent Energy Delivered + ReceivedVAhRead
Apparent Energy Delivered - ReceivedVAhRead
Reactive Energy in Quadrant IvarhRead
Reactive Energy in Quadrant IIvarhRead
Reactive Energy in Quadrant IIIvarhRead
Reactive Energy in Quadrant IVvarhRead
Permanent Active Energy Delivered (Into Load)WhRead
Permanent Active Energy Received (Out of Load)WhRead
Permanent Active Energy Delivered + ReceivedWhRead
Permanent Active Energy Delivered - ReceivedWhRead
Permanent Reactive Energy DeliveredvarhRead
Permanent Reactive Energy ReceivedvarhRead
Permanent Reactive Energy Delivered + ReceivedvarhRead
Permanent Reactive Energy Delivered - ReceivedvarhRead
Permanent Apparent Energy DeliveredVAhRead
Permanent Apparent Energy ReceivedVAhRead
Permanent Apparent Energy Delivered + ReceivedVAhRead
Permanent Apparent Energy Delivered - ReceivedVAhRead
Energy by Phase Reset Date/TimeRead
Active Energy Delivered Phase AWhRead
Active Energy Delivered Phase BWhRead
Active Energy Delivered Phase CWhRead
Reactive Energy Delivered Phase AvarhRead
Reactive Energy Delivered Phase BvarhRead
Reactive Energy Delivered Phase CvarhRead
Apparent Energy Delivered Phase AVAhRead
Apparent Energy Delivered Phase BVAhRead
Apparent Energy Delivered Phase CVAhRead
Power Demand MethodRead
Power Demand Interval DurationminRead
Power Demand Subinterval DurationminRead
Power Demand Elapsed Time in IntervalsRead
Power Demand Elapsed Time in SubintervalsRead
Power Demand Peak Reset Date/TimeRead
Current Demand MethodRead
Current Demand Interval DurationminRead
Current Demand Subinterval DurationminRead
Current Demand Elapsed Time in IntervalsRead
Current Demand Elapsed Time in SubintervalsRead
Current Demand Peak Reset Date/TimeRead
Active Power Demand System AssignmentRead
Active Power Register Number of Metered QuantityRead
Active Power Units CodeRead
Active Power Last DemandkWRead
Active Power Present DemandkWRead
Active Power Predicted DemandkWRead
Active Power Peak DemandkWRead
Active Power Peak Demand DateTimeRead
Reactive Power Demand System AssignmentRead
Reactive Power Register Number of Metered QuantityRead
Reactive Power Units CodeRead
Reactive Power Last DemandkvarRead
Reactive Power Present DemandkvarRead
Reactive Power Predicted DemandkvarRead
Reactive Power Peak DemandkvarRead
Reactive Power Peak Demand DateTimeRead
Apparent Power Demand System AssignmentRead
Apparent Power Register Number of Metered QuantityRead
Apparent Power Units CodeRead
Apparent Power Last DemandkVARead
Apparent Power Present DemandkVARead
Apparent Power Predicted DemandkVARead
Apparent Power Peak DemandkVARead
Apparent Power Peak Demand DateTimeRead
Current Avg Demand System AssignmentRead
Current Avg Register Number of Metered QuantityRead
Current Avg Units CodeRead
Current Avg Last DemandARead
Current Avg Present DemandARead
Current Avg Predicted DemandARead
Current Avg Peak DemandARead
Current Avg Peak Demand DateTimeRead
TOU/MT ModeRead
TOU/MT Energy Active RateRead
TOU/MT Energy Reset Date/TimeRead
MT Active Energy Delivered Rate 1WhRead
MT Active Energy Delivered Rate 2WhRead
MT Active Energy Delivered Rate 3WhRead
MT Active Energy Delivered Rate 4WhRead
MT Active Energy Received Rate 1WhRead
MT Active Energy Received Rate 2WhRead
MT Active Energy Received Rate 3WhRead
MT Active Energy Received Rate 4WhRead
MT Reactive Energy Delivered Rate 1varhRead
MT Reactive Energy Delivered Rate 2varhRead
MT Reactive Energy Delivered Rate 3varhRead
MT Reactive Energy Delivered Rate 4varhRead
MT Reactive Energy Received Rate 1varhRead
MT Reactive Energy Received Rate 2varhRead
MT Reactive Energy Received Rate 3varhRead
MT Reactive Energy Received Rate 4varhRead
MT Apparent Energy Delivered Rate 1VAhRead
MT Apparent Energy Delivered Rate 2VAhRead
MT Apparent Energy Delivered Rate 3VAhRead
MT Apparent Energy Delivered Rate 4VAhRead
MT Apparent Energy Received Rate 1VAhRead
MT Apparent Energy Received Rate 2VAhRead
MT Apparent Energy Received Rate 3VAhRead
MT Apparent Energy Received Rate 4VAhRead
MT Day Type Rate 1Read
MT Start Time Rate 1Read
MT End Time Rate 1Read
MT Start Month Rate1Read
MT Start Day Rate 1Read
MT End Month Rate 1Read
MT End Day Rate 1Read
MT Day Type Rate 2Read
MT Start Time Rate 2Read
MT End Time Rate 2Read
MT Start Month Rate2Read
MT Start Day Rate 2Read
MT End Month Rate 2Read
MT End Day Rate 2Read
MT Day Type Rate 3Read
MT Start Time Rate 3Read
MT End Time Rate 3Read
MT Start Month Rate3Read
MT Start Day Rate 3Read
MT End Month Rate 3Read
MT End Day Rate 3Read
MT Day Type Rate 4Read
MT Start Time Rate 4Read
MT End Time Rate 4Read
MT Start Month Rate4Read
MT Start Day Rate 4Read
MT End Month Rate 4Read
MT End Day Rate 4Read
MT Active Energy Delivered Rate 1 FloatkWhRead
MT Active Energy Delivered Rate 2 FloatkWhRead
MT Active Energy Delivered Rate 3 FloatkWhRead
MT Active Energy Delivered Rate 4 FloatkWhRead
MT Active Energy Received Rate 1 FloatkWhRead
MT Active Energy Received Rate 2 FloatkWhRead
MT Active Energy Received Rate 3 FloatkWhRead
MT Active Energy Received Rate 4 FloatkWhRead
MT Reactive Energy Delivered Rate 1 FloatkvarhRead
MT Reactive Energy Delivered Rate 2 FloatkvarhRead
MT Reactive Energy Delivered Rate 3 FloatkvarhRead
MT Reactive Energy Delivered Rate 4 FloatkvarhRead
MT Reactive Energy Received Rate 1 FloatkvarhRead
MT Reactive Energy Received Rate 2 FloatkvarhRead
MT Reactive Energy Received Rate 3 FloatkvarhRead
MT Reactive Energy Received Rate 4 FloatkvarhRead
MT Apparent Energy Delivered Rate 1 FloatkVAhRead
MT Apparent Energy Delivered Rate 2 FloatkVAhRead
MT Apparent Energy Delivered Rate 3 FloatkVAhRead
MT Apparent Energy Delivered Rate 4 FloatkVAhRead
MT Apparent Energy Received Rate 1 FloatkVAhRead
MT Apparent Energy Received Rate 2 FloatkVAhRead
MT Apparent Energy Received Rate 3 FloatkVAhRead
MT Apparent Energy Received Rate 4 FloatkVAhRead
HMI Model PresentRead
HMI Contrast SettingRead
HMI LanguageRead
HMI Date FormatRead
HMI Time FormatRead
HMI IEC/IEEE ModeRead
HMI Screen TimeoutminRead
HMI Backlight TimeoutminRead
HMI Language 01Read
HMI Language 02Read
HMI Language 03Read
HMI Language 04Read
HMI Language 05Read
HMI Language 06Read
HMI Language 07Read
HMI Language 08Read
Parameter1 AddressRead
Parameter2 AddressRead
Parameter3 AddressRead
Parameter4 AddressRead
RS-485 Comm Port (M/S) ProtocolRead
RS-485 Comm Port (M/S) AddressRead
RS-485 Comm Port (M/S) Baud RateRead
RS-485 Comm Port (M/S) ParityRead
Number of Multi-tariff Rates ActiveRead
Number of Digital Inputs Used to Control Multi-tariffRead
DI1A TypeRead
DI1A Control ModeRead
DI1A LabelRead
DI1A Debounce TimemsRead
DI2A TypeRead
DI2A Control ModeRead
DI2A LabelRead
DI2A Debounce TimemsRead
DI1A CountRead
DI1A On TimesRead
DI2A CountRead
DI2A On TimesRead
DO1A TypeRead
DO1A LabelRead
DO1A Enable/DisableRead
DO1A Behavioral ModeRead
DO1A On Time For Timed ModesRead
DO2A TypeRead
DO2A LabelRead
DO2A Enable/DisableRead
DO2A Behavioral ModeRead
DO2A On Time For Timed ModesRead
DO1B TypeRead
DO1B LabelRead
DO1B Enable/DisableRead
DO1B Behavioral ModeRead
DO1B On Time For Timed ModesRead
DO2B TypeRead
DO2B LabelRead
DO2B Enable/DisableRead
DO2B Behavioral ModeRead
DO2B On Time For Timed ModesRead
DO Default StateRead
DO1A Operating Mode StatusRead
DO1A Control Mode StatusRead
DO1A Behavioral Mode StatusRead
DO1A CountRead
DO1A On TimesRead
DO2A Operating Mode StatusRead
DO2A Control Mode StatusRead
DO2A Behavioral Mode StatusRead
DO2A CountRead
DO2A On TimesRead
DO1B Operating Mode StatusRead
DO1B Control Mode StatusRead
DO1B Behavioral Mode StatusRead
DO1B CountRead
DO1B On TimesRead
DO2B Operating Mode StatusRead
DO2B Control Mode StatusRead
DO2B Behavioral Mode StatusRead
DO2B CountRead
DO2B On TimesRead
Analog Input 1 Scaled ValueRead
Analog Input 2 Scaled ValueRead
Analog Output 1 Normalized ValueRead
Analog Output 2 Normalized ValueRead
Logging StatusRead
Allocated File SizeRead
Allocated Record SizeRead
Record Management MethodRead
File StatusRead
Number of Records in FileRead
First Record Sequence NumberRead
Last Record Sequence NumberRead
Topic ModeRead
Start TimeminRead
Stop TimesRead
Interval Control MinutesminRead
Interval Control SecondssRead
Date/Time Last ClearRead
Record Item 1Read
Record Item 2Read
Processor Loading%Read
Meter Self-Test Word 1Read
Meter Self-Test Word 2Read
Meter Self-Test Word 3Read
Meter Self-Test Word 4Read
Meter Self-Test Word 5Read
HS FrequencyHzRead
THD Current A%Read
THD Current B%Read
THD Current C%Read
THD Current N%Read
THD Current G%Read
THD Total RMS Current A%Read
THD Total RMS Current B%Read
THD Total RMS Current C%Read
THD Total RMS Current N%Read
THD Total RMS Current G%Read
THD Voltage A-B%Read
THD Voltage B-C%Read
THD Voltage C-A%Read
THD Voltage L-L%Read
THD Voltage A-N%Read
THD Voltage B-N%Read
THD Voltage C-N%Read
THD Voltage L-N%Read
THD Total RMS Voltage A-B%Read
THD Total RMS Voltage B-C%Read
THD Total RMS Voltage C-A%Read
THD Total RMS Voltage L-L%Read
THD Total RMS Voltage A-N%Read
THD Total RMS Voltage B-N%Read
THD Total RMS Voltage C-N%Read
THD Total RMS Voltage N-G%Read
THD Total RMS Voltage L-N%Read
Voltage A-B H1 Magnitude%Read
Voltage A-B H2 Magnitude%Read
Voltage A-B H3 Magnitude%Read
Voltage A-B H4 Magnitude%Read
Voltage A-B H5 Magnitude%Read
Voltage A-B H6 Magnitude%Read
Voltage A-B H7 Magnitude%Read
Voltage A-B H8 Magnitude%Read
Voltage A-B H9 Magnitude%Read
Voltage A-B H10 Magnitude%Read
Voltage A-B H11 Magnitude%Read
Voltage A-B H12 Magnitude%Read
Voltage A-B H13 Magnitude%Read
Voltage A-B H14 Magnitude%Read
Voltage A-B H15 Magnitude%Read
Voltage A-B H16 Magnitude%Read
Voltage A-B H17 Magnitude%Read
Voltage A-B H18 Magnitude%Read
Voltage A-B H19 Magnitude%Read
Voltage A-B H20 Magnitude%Read
Voltage A-B H21 Magnitude%Read
Voltage A-B H22 Magnitude%Read
Voltage A-B H23 Magnitude%Read
Voltage A-B H24 Magnitude%Read
Voltage A-B H25 Magnitude%Read
Voltage A-B H26 Magnitude%Read
Voltage A-B H27 Magnitude%Read
Voltage A-B H28 Magnitude%Read
Voltage A-B H29 Magnitude%Read
Voltage A-B H30 Magnitude%Read
Voltage A-B H31 Magnitude%Read
Voltage B-C H1 Magnitude%Read
Voltage B-C H2 Magnitude%Read
Voltage B-C H3 Magnitude%Read
Voltage B-C H4 Magnitude%Read
Voltage B-C H5 Magnitude%Read
Voltage B-C H6 Magnitude%Read
Voltage B-C H7 Magnitude%Read
Voltage B-C H8 Magnitude%Read
Voltage B-C H9 Magnitude%Read
Voltage B-C H10 Magnitude%Read
Voltage B-C H11 Magnitude%Read
Voltage B-C H12 Magnitude%Read
Voltage B-C H13 Magnitude%Read
Voltage B-C H14 Magnitude%Read
Voltage B-C H15 Magnitude%Read
Voltage B-C H16 Magnitude%Read
Voltage B-C H17 Magnitude%Read
Voltage B-C H18 Magnitude%Read
Voltage B-C H19 Magnitude%Read
Voltage B-C H20 Magnitude%Read
Voltage B-C H21 Magnitude%Read
Voltage B-C H22 Magnitude%Read
Voltage B-C H23 Magnitude%Read
Voltage B-C H24 Magnitude%Read
Voltage B-C H25 Magnitude%Read
Voltage B-C H26 Magnitude%Read
Voltage B-C H27 Magnitude%Read
Voltage B-C H28 Magnitude%Read
Voltage B-C H29 Magnitude%Read
Voltage B-C H30 Magnitude%Read
Voltage B-C H31 Magnitude%Read
Voltage C-A H1 Magnitude%Read
Voltage C-A H2 Magnitude%Read
Voltage C-A H3 Magnitude%Read
Voltage C-A H4 Magnitude%Read
Voltage C-A H5 Magnitude%Read
Voltage C-A H6 Magnitude%Read
Voltage C-A H7 Magnitude%Read
Voltage C-A H8 Magnitude%Read
Voltage C-A H9 Magnitude%Read
Voltage C-A H10 Magnitude%Read
Voltage C-A H11 Magnitude%Read
Voltage C-A H12 Magnitude%Read
Voltage C-A H13 Magnitude%Read
Voltage C-A H14 Magnitude%Read
Voltage C-A H15 Magnitude%Read
Voltage C-A H16 Magnitude%Read
Voltage C-A H17 Magnitude%Read
Voltage C-A H18 Magnitude%Read
Voltage C-A H19 Magnitude%Read
Voltage C-A H20 Magnitude%Read
Voltage C-A H21 Magnitude%Read
Voltage C-A H22 Magnitude%Read
Voltage C-A H23 Magnitude%Read
Voltage C-A H24 Magnitude%Read
Voltage C-A H25 Magnitude%Read
Voltage C-A H26 Magnitude%Read
Voltage C-A H27 Magnitude%Read
Voltage C-A H28 Magnitude%Read
Voltage C-A H29 Magnitude%Read
Voltage C-A H30 Magnitude%Read
Voltage C-A H31 Magnitude%Read
Voltage A-N H1 Magnitude%Read
Voltage A-N H2 Magnitude%Read
Voltage A-N H3 Magnitude%Read
Voltage A-N H4 Magnitude%Read
Voltage A-N H5 Magnitude%Read
Voltage A-N H6 Magnitude%Read
Voltage A-N H7 Magnitude%Read
Voltage A-N H8 Magnitude%Read
Voltage A-N H9 Magnitude%Read
Voltage A-N H10 Magnitude%Read
Voltage A-N H11 Magnitude%Read
Voltage A-N H12 Magnitude%Read
Voltage A-N H13 Magnitude%Read
Voltage A-N H14 Magnitude%Read
Voltage A-N H15 Magnitude%Read
Voltage A-N H16 Magnitude%Read
Voltage A-N H17 Magnitude%Read
Voltage A-N H18 Magnitude%Read
Voltage A-N H19 Magnitude%Read
Voltage A-N H20 Magnitude%Read
Voltage A-N H21 Magnitude%Read
Voltage A-N H22 Magnitude%Read
Voltage A-N H23 Magnitude%Read
Voltage A-N H24 Magnitude%Read
Voltage A-N H25 Magnitude%Read
Voltage A-N H26 Magnitude%Read
Voltage A-N H27 Magnitude%Read
Voltage A-N H28 Magnitude%Read
Voltage A-N H29 Magnitude%Read
Voltage A-N H30 Magnitude%Read
Voltage A-N H31 Magnitude%Read
Voltage B-N H1 Magnitude%Read
Voltage B-N H2 Magnitude%Read
Voltage B-N H3 Magnitude%Read
Voltage B-N H4 Magnitude%Read
Voltage B-N H5 Magnitude%Read
Voltage B-N H6 Magnitude%Read
Voltage B-N H7 Magnitude%Read
Voltage B-N H8 Magnitude%Read
Voltage B-N H9 Magnitude%Read
Voltage B-N H10 Magnitude%Read
Voltage B-N H11 Magnitude%Read
Voltage B-N H12 Magnitude%Read
Voltage B-N H13 Magnitude%Read
Voltage B-N H14 Magnitude%Read
Voltage B-N H15 Magnitude%Read
Voltage B-N H16 Magnitude%Read
Voltage B-N H17 Magnitude%Read
Voltage B-N H18 Magnitude%Read
Voltage B-N H19 Magnitude%Read
Voltage B-N H20 Magnitude%Read
Voltage B-N H21 Magnitude%Read
Voltage B-N H22 Magnitude%Read
Voltage B-N H23 Magnitude%Read
Voltage B-N H24 Magnitude%Read
Voltage B-N H25 Magnitude%Read
Voltage B-N H26 Magnitude%Read
Voltage B-N H27 Magnitude%Read
Voltage B-N H28 Magnitude%Read
Voltage B-N H29 Magnitude%Read
Voltage B-N H30 Magnitude%Read
Voltage B-N H31 Magnitude%Read
Voltage C-N H1 Magnitude%Read
Voltage C-N H2 Magnitude%Read
Voltage C-N H3 Magnitude%Read
Voltage C-N H4 Magnitude%Read
Voltage C-N H5 Magnitude%Read
Voltage C-N H6 Magnitude%Read
Voltage C-N H7 Magnitude%Read
Voltage C-N H8 Magnitude%Read
Voltage C-N H9 Magnitude%Read
Voltage C-N H10 Magnitude%Read
Voltage C-N H11 Magnitude%Read
Voltage C-N H12 Magnitude%Read
Voltage C-N H13 Magnitude%Read
Voltage C-N H14 Magnitude%Read
Voltage C-N H15 Magnitude%Read
Voltage C-N H16 Magnitude%Read
Voltage C-N H17 Magnitude%Read
Voltage C-N H18 Magnitude%Read
Voltage C-N H19 Magnitude%Read
Voltage C-N H20 Magnitude%Read
Voltage C-N H21 Magnitude%Read
Voltage C-N H22 Magnitude%Read
Voltage C-N H23 Magnitude%Read
Voltage C-N H24 Magnitude%Read
Voltage C-N H25 Magnitude%Read
Voltage C-N H26 Magnitude%Read
Voltage C-N H27 Magnitude%Read
Voltage C-N H28 Magnitude%Read
Voltage C-N H29 Magnitude%Read
Voltage C-N H30 Magnitude%Read
Voltage C-N H31 Magnitude%Read
Current A H1 Magnitude%Read
Current A H2 Magnitude%Read
Current A H3 Magnitude%Read
Current A H4 Magnitude%Read
Current A H5 Magnitude%Read
Current A H6 Magnitude%Read
Current A H7 Magnitude%Read
Current A H8 Magnitude%Read
Current A H9 Magnitude%Read
Current A H10 Magnitude%Read
Current A H11 Magnitude%Read
Current A H12 Magnitude%Read
Current A H13 Magnitude%Read
Current A H14 Magnitude%Read
Current A H15 Magnitude%Read
Current A H16 Magnitude%Read
Current A H17 Magnitude%Read
Current A H18 Magnitude%Read
Current A H19 Magnitude%Read
Current A H20 Magnitude%Read
Current A H21 Magnitude%Read
Current A H22 Magnitude%Read
Current A H23 Magnitude%Read
Current A H24 Magnitude%Read
Current A H25 Magnitude%Read
Current A H26 Magnitude%Read
Current A H27 Magnitude%Read
Current A H28 Magnitude%Read
Current A H29 Magnitude%Read
Current A H30 Magnitude%Read
Current A H31 Magnitude%Read
Current B H1 Magnitude%Read
Current B H2 Magnitude%Read
Current B H3 Magnitude%Read
Current B H4 Magnitude%Read
Current B H5 Magnitude%Read
Current B H6 Magnitude%Read
Current B H7 Magnitude%Read
Current B H8 Magnitude%Read
Current B H9 Magnitude%Read
Current B H10 Magnitude%Read
Current B H11 Magnitude%Read
Current B H12 Magnitude%Read
Current B H13 Magnitude%Read
Current B H14 Magnitude%Read
Current B H15 Magnitude%Read
Current B H16 Magnitude%Read
Current B H17 Magnitude%Read
Current B H18 Magnitude%Read
Current B H19 Magnitude%Read
Current B H20 Magnitude%Read
Current B H21 Magnitude%Read
Current B H22 Magnitude%Read
Current B H23 Magnitude%Read
Current B H24 Magnitude%Read
Current B H25 Magnitude%Read
Current B H26 Magnitude%Read
Current B H27 Magnitude%Read
Current B H28 Magnitude%Read
Current B H29 Magnitude%Read
Current B H30 Magnitude%Read
Current B H31 Magnitude%Read
Current C H1 Magnitude%Read
Current C H2 Magnitude%Read
Current C H3 Magnitude%Read
Current C H4 Magnitude%Read
Current C H5 Magnitude%Read
Current C H6 Magnitude%Read
Current C H7 Magnitude%Read
Current C H8 Magnitude%Read
Current C H9 Magnitude%Read
Current C H10 Magnitude%Read
Current C H11 Magnitude%Read
Current C H12 Magnitude%Read
Current C H13 Magnitude%Read
Current C H14 Magnitude%Read
Current C H15 Magnitude%Read
Current C H16 Magnitude%Read
Current C H17 Magnitude%Read
Current C H18 Magnitude%Read
Current C H19 Magnitude%Read
Current C H20 Magnitude%Read
Current C H21 Magnitude%Read
Current C H22 Magnitude%Read
Current C H23 Magnitude%Read
Current C H24 Magnitude%Read
Current C H25 Magnitude%Read
Current C H26 Magnitude%Read
Current C H27 Magnitude%Read
Current C H28 Magnitude%Read
Current C H29 Magnitude%Read
Current C H30 Magnitude%Read
Current C H31 Magnitude%Read
Harmonics Auto Reset Day1Read
Harmonics Auto Reset Month1Read
Harmonics Auto Reset Day2Read
Harmonics Auto Reset Month2Read
Harmonics Auto Reset Day3Read
Harmonics Auto Reset Month3Read
Harmonics Auto Reset Day4Read
Harmonics Auto Reset Month4Read
Harmonics Auto Reset Day5Read
Harmonics Auto Reset Month5Read
Harmonics Auto Reset Day6Read
Harmonics Auto Reset Month6Read
Harmonics Auto Reset Day7Read
Harmonics Auto Reset Month7Read
Harmonics Auto Reset Day8Read
Harmonics Auto Reset Month8Read
Harmonics Auto Reset Day9Read
Harmonics Auto Reset Month9Read
Harmonics Auto Reset Day10Read
Harmonics Auto Reset Month10Read
Harmonics Auto Reset Day11Read
Harmonics Auto Reset Month11Read
Harmonics Auto Reset Day12Read
Harmonics Auto Reset Month12Read
Harmonics Auto Reset A.SuppressionmARead
Max/Min Reset Date and TimeRead
Max Current AvgARead
Max Current Avg Occurrence Date TimeRead
Max Voltage L-L AvgVRead
Max Voltage L-L Avg - Occurrence Date TimeRead
Max Voltage L-N AvgVRead
Max Voltage L-N Avg - Occurrence Date TimeRead
Max Active Power TotalWRead
Max Active Power Total -occurrence Date TimeRead
Max Reactive Power TotalvarRead
Max Reactive Power Total -occurrence Date TimeRead
Max Apparent Power TotalVARead
Max Apparent Power Total - Occurrence Date TimeRead
Max Power Factor TotalRead
Max Power Factor Total -occurrence Date TimeRead
Max FrequencyHzRead
Max Frequency Occurrence Date TimeRead
Min Current AvgARead
Min Current Avg Occurrence Date TimeRead
Min Voltage L-L AvgVRead
Min Voltage L-L Avg Occurrence Date TimeRead
Min Voltage L-N AvgVRead
Min Voltage L-N Avg Occurrence Date TimeRead
Min Active Power TotalWRead
Min Active Power Total Occurrence Date TimeRead
Min Reactive Power TotalvarRead
Min Reactive Power Total Occurrence Date TimeRead
Min Apparent Power TotalVARead
Min Apparent Power Total Occurrence Date TimeRead
Min Power Factor TotalRead
Min Power Factor Total Occurrence Date TimeRead
Min FrequencyHzRead
Min Frequency Occurrence Date TimeRead
Max Current NeutralARead
Max Current Neutral Occurrence Date TimeRead
Min Current NeutralARead
Min Current Neutral Occurrence Date TimeRead
Last Cleared Active Energy Delivered (Into Load) FloatkWhRead
Last Cleared Active Energy Received (Out of Load) FloatkWhRead
Last Cleared Active Energy Delivered + Received FloatkWhRead
Last Cleared Active Energy Delivered - Received FloatkWhRead
Last Cleared Reactive Energy Delivered FloatkvarhRead
Last Cleared Reactive Energy Received FloatkvarhRead
Last Cleared Reactive Energy Delivered + Received FloatkvarhRead
Last Cleared Reactive Energy Delivered - Received FloatkvarhRead
Last Cleared Apparent Energy Delivered FloatkVAhRead
Last Cleared Apparent Energy Received FloatkVAhRead
Last Cleared Apparent Energy Delivered + Received FloatkVAhRead
Last Cleared Apparent Energy Delivered - Received FloatkVAhRead
Phase Angle Between Voltage A and Current ARead
Phase Angle Between Voltage B and Current BRead
Phase Angle Between Voltage C and Current CRead
Run Sec Delivered (Into Load)sRead
Run Sec Received (Out of Load)sRead
Last Cleared Active Energy Delivered (Into Load)WhRead
Last Cleared Active Energy Received (Out of Load)WhRead
Last Cleared Active Energy Delivered + ReceivedWhRead
Last Cleared Active Energy Delivered - ReceivedWhRead
Last Cleared Reactive Energy DeliveredvarhRead
Last Cleared Reactive Energy ReceivedvarhRead
Last Cleared Reactive Energy Delivered + ReceivedvarhRead
Last Cleared Reactive Energy Delivered - ReceivedvarhRead
Last Cleared Apparent Energy DeliveredVAhRead
Last Cleared Apparent Energy ReceivedVAhRead
Last Cleared Apparent Energy Delivered + ReceivedVAhRead
Last Cleared Apparent Energy Delivered - ReceivedVAhRead
Last Cleared Run Sec Delivered (Into Load)sRead
Last Cleared Run Sec Received (Out of Load)sRead
Last Cleared Rate 1 ValueRead
Last Cleared Rate 2 ValueRead
AI A01 TypeRead
AI A01 LabelRead
AI A01 Units CodeRead
AI A01 Scale CodeRead
AI A01 Range SelectRead
AI A01 Analog Input MinimumRead
AI A01 Analog Input MaximumRead
AI A01 Present Raw ValueRead
AI A01 Present Scaled ValueRead
AI A01 IO Point Diagnostic BitmapRead
AI A02 TypeRead
AI A02 LabelRead
AI A02 Units CodeRead
AI A02 Scale CodeRead
AI A02 Range SelectRead
AI A02 Analog Input MinimumRead
AI A02 Analog Input MaximumRead
AI A02 Present Raw ValueRead
AI A02 Present Scaled ValueRead
AI A02 IO Point Diagnostic BitmapRead
AO A01 TypeRead
AO A01 LabelRead
AO A01 Range SelectRead
AO A01 Output EnableRead
AO A01 Reference Register NumberRead
AO A01 Lower Limit Register ValueRead
AO A01 Upper Limit Register ValueRead
AO A01 Present Analog ValueRead
AO A01 Present Raw (Register) ValueRead
AO A01 Calibration OffsetRead
AO A01 Calibration GainRead
AO A01 Present Digital ValueRead
AO A01 IO Point Diagnostic BitmapRead
AO A02 TypeRead
AO A02 LabelRead
AO A02 Range SelectRead
AO A02 Output EnableRead
AO A02 Reference Register NumberRead
AO A02 Lower Limit Register ValueRead
AO A02 Upper Limit Register ValueRead
AO A02 Present Analog ValueRead
AO A02 Present Raw (Register) ValueRead
AO A02 Calibration OffsetRead
AO A02 Calibration GainRead
AO A02 Present Digital ValueRead
AO A02 IO Point Diagnostic BitmapRead
Acc Active Energy Received Phase AWhRead
Acc Active Energy Received Phase BWhRead
Acc Active Energy Received Phase CWhRead
Acc Active Energy Delivered + Received Phase AWhRead
Acc Active Energy Delivered + Received Phase BWhRead
Acc Active Energy Delivered + Received Phase CWhRead
Acc Active Energy Delivered - Received Phase AWhRead
Acc Active Energy Delivered - Received Phase BWhRead
Acc Active Energy Delivered - Received Phase CWhRead
Acc Reactive Energy Received Phase AvarhRead
Acc ReactiveEnergy Received Phase BvarhRead
Acc Reactive Energy Received Phase CvarhRead
Acc Reactive Energy Delivered + Received Phase AvarhRead
Acc Reactive Energy Delivered + Received Phase BvarhRead
Acc Reactive Energy Delivered + Received Phase CvarhRead
Acc Reactive Energy Delivered - Received Phase AvarhRead
Acc Reactive Energy Delivered - Received Phase BvarhRead
Acc Reactive Energy Delivered - Received Phase CvarhRead
Acc Apparent Energy Received Phase AVAhRead
Acc Apparent Energy Received Phase BVAhRead
Acc Apparent Energy Received Phase CVAhRead
Acc Apparent Energy Delivered + Received Phase AVAhRead
Acc Apparent Energy Delivered + Received Phase BVAhRead
Acc Apparent Energy Delivered + Received Phase CVAhRead
Acc Apparent Energy Delivered - Received Phase AVAhRead
Acc Apparent Energy Delivered - Received Phase BVAhRead
Acc Apparent Energy Delivered - Received Phase CVAhRead
Acc Active Energy Received Phase A FloatkWhRead
Acc Active Energy Received Phase B FloatkWhRead
Acc Active Energy Received Phase C FloatkWhRead
Acc Active Energy Delivered + Received Phase A FloatkWhRead
Acc Active Energy Delivered + Received Phase B FloatkWhRead
Acc Active Energy Delivered + Received Phase C FloatkWhRead
Acc Active Energy Delivered - Received Phase A FloatkWhRead
Acc Active Energy Delivered - Received Phase B FloatkWhRead
Acc Active Energy Delivered - Received Phase C FloatkWhRead
Acc Reactive Energy Received Phase A FloatkvarhRead
Acc ReactiveEnergy Received Phase B FloatkvarhRead
Acc Reactive Energy Received Phase C FloatkvarhRead
Acc Reactive Energy Delivered + Received Phase A FloatkvarhRead
Acc Reactive Energy Delivered + Received Phase B FloatkvarhRead
Acc Reactive Energy Delivered + Received Phase C FloatkvarhRead
Acc Reactive Energy Delivered - Received Phase A FloatkvarhRead
Acc Reactive Energy Delivered - Received Phase B FloatkvarhRead
Acc Reactive Energy Delivered - Received Phase C FloatkvarhRead
Acc Apparent Energy Received Phase A FloatkVAhRead
Acc Apparent Energy Received Phase B FloatkVAhRead
Acc Apparent Energy Received Phase C FloatkVAhRead
Acc Apparent Energy Delivered + Received Phase A FloatkVAhRead
Acc Apparent Energy Delivered + Received Phase B FloatkVAhRead
Acc Apparent Energy Delivered + Received Phase C FloatkVAhRead
Acc Apparent Energy Delivered - Received Phase A FloatkVAhRead
Acc Apparent Energy Delivered - Received Phase B FloatkVAhRead
Acc Apparent Energy Delivered - Received Phase C FloatkVAhRead
Last Cleared Active Energy Delivered Phase AWhRead
Last Cleared Active Energy Delivered Phase BWhRead
Last Cleared Active Energy Delivered Phase CWhRead
Last Cleared Active Energy Recieved Phase AWhRead
Last Cleared Active Energy Recieved Phase BWhRead
Last Cleared Active Energy Recieved Phase CWhRead
Last Cleared Active Energy Delivered + Received Phase AWhRead
Last Cleared Active Energy Delivered + Received Phase BWhRead
Last Cleared Active Energy Delivered + Received Phase CWhRead
Last Cleared Active Energy Delivered - Received Phase AWhRead
Last Cleared Active Energy Delivered - Received Phase BWhRead
Last Cleared Active Energy Delivered - Received Phase CWhRead
Last Cleared Reactive Energy Delivered Phase AvarhRead
Last Cleared Reactive Energy Delivered Phase BvarhRead
Last Cleared Reactive Energy Delivered Phase CvarhRead
Last Cleared Reactive Energy Recieved Phase AvarhRead
Last Cleared ReactiveEnergy Recieved Phase BvarhRead
Last Cleared Reactive Energy Recieved Phase CvarhRead
Last Cleared Reactive Energy Delivered + Received Phase AvarhRead
Last Cleared Reactive Energy Delivered + Received Phase BvarhRead
Last Cleared Reactive Energy Delivered + Received Phase CvarhRead
Last Cleared Reactive Energy Delivered - Received Phase AvarhRead
Last Cleared Reactive Energy Delivered - Received Phase BvarhRead
Last Cleared Reactive Energy Delivered - Received Phase CvarhRead
Last Cleared Apparent Energy Delivered Phase AVAhRead
Last Cleared Apparent Energy Delivered Phase BVAhRead
Last Cleared Apparent Energy Delivered Phase CVAhRead
Last Cleared Apparent Energy Recieved Phase AVAhRead
Last Cleared Apparent Energy Recieved Phase BVAhRead
Last Cleared Apparent Energy Recieved Phase CVAhRead
Last Cleared Apparent Energy Delivered + Received Phase AVAhRead
Last Cleared Apparent Energy Delivered + Received Phase BVAhRead
Last Cleared Apparent Energy Delivered + Received Phase CVAhRead
Last Cleared Apparent Energy Delivered - Received Phase AVAhRead
Last Cleared Apparent Energy Delivered - Received Phase BVAhRead
Last Cleared Apparent Energy Delivered - Received Phase CVAhRead
Last Cleared Active Energy Delivered Phase A FloatkWhRead
Last Cleared Active Energy Delivered Phase B FloatkWhRead
Last Cleared Active Energy Delivered Phase C FloatkWhRead
Last Cleared Active Energy Recieved Phase A FloatkWhRead
Last Cleared Active Energy Recieved Phase B FloatkWhRead
Last Cleared Active Energy Recieved Phase C FloatkWhRead
Last Cleared Active Energy Delivered + Received Phase A FloatkWhRead
Last Cleared Active Energy Delivered + Received Phase B FloatkWhRead
Last Cleared Active Energy Delivered + Received Phase C FloatkWhRead
Last Cleared Active Energy Delivered - Received Phase A FloatkWhRead
Last Cleared Active Energy Delivered - Received Phase B FloatkWhRead
Last Cleared Active Energy Delivered - Received Phase C FloatkWhRead
Last Cleared Reactive Energy Delivered Phase A FloatkvarhRead
Last Cleared Reactive Energy Delivered Phase B FloatkvarhRead
Last Cleared Reactive Energy Delivered Phase C FloatkvarhRead
Last Cleared Reactive Energy Recieved Phase A FloatkvarhRead
Last Cleared ReactiveEnergy Recieved Phase B FloatkvarhRead
Last Cleared Reactive Energy Recieved Phase C FloatkvarhRead
Last Cleared Reactive Energy Delivered + Received Phase A FloatkvarhRead
Last Cleared Reactive Energy Delivered + Received Phase B FloatkvarhRead
Last Cleared Reactive Energy Delivered + Received Phase C FloatkvarhRead
Last Cleared Reactive Energy Delivered - Received Phase A FloatkvarhRead
Last Cleared Reactive Energy Delivered - Received Phase B FloatkvarhRead
Last Cleared Reactive Energy Delivered - Received Phase C FloatkvarhRead
Last Cleared Apparent Energy Delivered Phase A FloatkVAhRead
Last Cleared Apparent Energy Delivered Phase B FloatkVAhRead
Last Cleared Apparent Energy Delivered Phase C FloatkVAhRead
Last Cleared Apparent Energy Recieved Phase A FloatkVAhRead
Last Cleared Apparent Energy Recieved Phase B FloatkVAhRead
Last Cleared Apparent Energy Recieved Phase C FloatkVAhRead
Last Cleared Apparent Energy Delivered + Received Phase A FloatkVAhRead
Last Cleared Apparent Energy Delivered + Received Phase B FloatkVAhRead
Last Cleared Apparent Energy Delivered + Received Phase C FloatkVAhRead
Last Cleared Apparent Energy Delivered - Received Phase A FloatkVAhRead
Last Cleared Apparent Energy Delivered - Received Phase B FloatkVAhRead
Last Cleared Apparent Energy Delivered - Received Phase C FloatkVAhRead

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Show current, voltage, power and power factor per phase on a dashboard for each distribution board.
  • Track energy delivered and received per tariff and per phase in the history for sub-metering reports.
  • Get an alert when peak demand or the total current goes above a threshold you set.
  • Watch voltage and current THD over time to spot non-linear loads in a building.
  • Compare the min and max values with their time stamps after a power quality complaint.

Installation

  1. Connect D0, D1 and the shield of the meter to the RS485 port of the ModbusCloud Gateway and terminate the last device on the bus.

  2. On the meter display set the protocol to Modbus, an unused address, the baud rate and the parity.

  3. In ModbusCloud add a Modbus device with the same address and serial settings and import this template.

  4. Check that current, voltage and frequency come in with plausible values for your installation.

Things to watch for

The meter does not answer. What should I check?

Compare address, baud rate and parity on the meter display with the settings in ModbusCloud; the protocol must be Modbus, not Jbus or ASCII. Swap D0 and D1 if needed, and check that only the two ends of the bus have a terminating resistor.

Power and energy look too high or too low by a constant factor.

Check the CT and VT ratios and the wiring type in the meter setup. The meter scales with these ratios, so a wrong primary current gives every power and energy value the same error. Energy counters are in Wh and varh, power in kW.

Why can I not change the meter settings by writing a register?

The PM2200 changes its settings through a command interface: you write a command number and its parameters, not the setting itself. That interface is in the Alarms and Commands template. Use it with care, because a wrong command can reset energy or change the CT ratio.

Some harmonic and I/O registers stay empty.

Individual harmonics, the analog and digital I/O and the energy log are PM2230 functions, and I/O only works with the option module fitted. On a PM2220 these registers return no data or the not-available value.

Want to see how it works?

Electrician working in an open distribution board