E+E Elektronik Modbus templates

All 12 available E+E Elektronik templates for ModbusCloud.

Read E+E Elektronik humidity, temperature, CO2, differential pressure and air velocity sensors via Modbus RTU.

Templates
12
Connection
Modbus RTU and TCP
Registers
1 to 5 per template
Compatible models
EE431 · EE441 · EE451 · EE471 · EE872 · EE260 · EE072 · EE800 · EE600 · EE671 · EE210 · EE074 · EE310 · EE650 · EE680
Last updated

E+E Elektronik templates

11 via Modbus RTU, 1 via Modbus TCP

The scan recognises these devices

Connect them to RS485 or the network and start a scan in the portal.

Gateway

€295one-off

Portal

€149per year

Incl. 4G data up to 30 MB per month

or
€495one-off

Excl. VAT. White label customer portal included. All prices

Order your first gateway

100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

The ModbusCloud Gateway with the RS485 terminal and the antenna connectors

E+E Elektronik, based in Engerwitzdorf (Austria), manufactures precision climate and process sensors used across HVAC, pharma, clean rooms, meteorology, and industrial drying. The 12 E+E Elektronik Modbus RTU templates in our library cover humidity and temperature probes (EE072, EE074, EE210, EE260, EE310), temperature-only transmitters (EE4x1), differential pressure (EE600), thermal air-velocity sensors (EE650, EE671, EE680), and combined CO2/humidity/temperature room sensors (EE800, EE872).

With ModbusCloud and these E+E Elektronik templates you get float32 readings of relative and absolute humidity, dew point, frost point, enthalpy, air velocity, differential pressure, CO2 concentration, and accurate temperature in Celsius or Kelvin. The heated EE260 probe is specifically designed for meteorological and high-humidity outdoor use; the EE310 handles industrial ranges up to 180 °C and 20 bar. All data arrives over Modbus RTU as calibrated engineering values, no raw A/D conversion.

All 12 E+E Elektronik templates are free to browse. Import one into your ModbusCloud portal to read calibrated climate data live within minutes, without decoding E+E register maps from datasheets.

What you can read out

  • Relative and absolute humidity
  • Dew point and frost point
  • Air velocity and temperature
  • CO2 concentration (EE800, EE872)
  • Differential pressure (EE600)

Typical installations

  • Clean rooms, pharma production and laboratory climate control
  • Meteorological stations and outdoor humidity monitoring
  • HVAC ventilation ducts and air handling units

Want to see how it works?

Electrician working in an open distribution board