SunSpec Modbus templates

All 88 available SunSpec templates for ModbusCloud.

Monitor SunSpec-compliant inverters, storage systems, and meters using the standard SunSpec Modbus register models.

Templates
88
Connection
Modbus RTU and TCP
Registers
2 to 93 per template
Compatible models
SunSpec Model 112 — Inverter (Split Phase) FLOAT · SunSpec Model 113 — Inverter (Three Phase) FLOAT · SunSpec Model 102 — Inverter (Split-Phase) · SunSpec Model 103 — Inverter (Three Phase) · SunSpec Model 132 — Volt-Watt · SunSpec Model 130 — HVRTD · SunSpec Model 137 — LVRTC · SunSpec Model 138 — HVRTC · SunSpec Model 136 — HFRT · SunSpec Model 141 — LFRTC · SunSpec Model 142 — HFRTC · SunSpec Model 140 — HVRTX · SunSpec Model 144 — HFRTX · SunSpec Model 203 — wye-connect three phase (abcn) meter · SunSpec Model 204 — delta-connect three phase (abc) meter · SunSpec Model 212 — split single phase (ABN) meter · SunSpec Model 213 — wye-connect three phase (abcn) meter · SunSpec Model 214 — delta-connect three phase (abc) meter · SunSpec Model 303 — Back of Module Temperature Model · SunSpec Model 304 — Inclinometer Model · SunSpec Model 63002 — SunSpec Test Model 2 · SunSpec Model 706 — DER Volt-Watt · SunSpec Model 708 — DER Trip HV · SunSpec Model 710 — DER Trip HF
Last updated

SunSpec templates

2 via Modbus RTU, 84 via Modbus TCP

The scan recognises these devices

Connect them to RS485 or the network and start a scan in the portal.

Gateway

€295one-off

Portal

€149per year

Incl. 4G data up to 30 MB per month

or
€495one-off

Excl. VAT. White label customer portal included. All prices

Order your first gateway

100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

The ModbusCloud Gateway with the RS485 terminal and the antenna connectors

SunSpec is an open information model for solar inverters, energy storage, meters, and environmental sensors. Rather than a manufacturer, SunSpec defines a standardised set of Modbus register models (103 Three Phase Inverter, 111/112 Float Inverters, 120 Nameplate, 122 Measurements & Status, 123 Immediate Controls, 124 Storage, and more) that many hardware vendors implement. If your device carries the SunSpec label, these templates give you a drop-in configuration without digging through vendor-specific register maps.

ModbusCloud ships ready-made templates for the full SunSpec model family so you can read nameplate data, live AC and DC measurements, status flags, storage state, and basic settings over Modbus. Whether the device speaks Modbus TCP over Ethernet or RTU over RS485, pick the SunSpec model that matches the firmware and the register addresses, scaling factors, and data types are already mapped. That matters for fleets where installers meet mixed hardware but want one consistent dashboard.

All SunSpec templates are free to browse. Import the model that matches your device into your ModbusCloud portal and read live data within minutes — no register mapping, no combing through SunSpec specification PDFs.

What you can read out

  • AC active power and energy totals
  • DC voltage, current, and power
  • Inverter operating state and event flags
  • Battery state of charge and storage limits
  • Nameplate ratings and device identification

Typical installations

  • Mixed-vendor PV fleets standardised on SunSpec-compliant inverters and meters
  • Commercial storage sites where operators need one register model across hardware
  • Retrofit projects replacing legacy loggers with standards-based Modbus polling

Want to see how it works?

Electrician working in an open distribution board