SunSpec Modbus templates
All 88 available SunSpec templates for ModbusCloud.
Monitor SunSpec-compliant inverters, storage systems, and meters using the standard SunSpec Modbus register models.
- Templates
- 88
- Connection
- Modbus RTU and TCP
- Registers
- 2 to 93 per template
- Compatible models
- SunSpec Model 112 — Inverter (Split Phase) FLOAT · SunSpec Model 113 — Inverter (Three Phase) FLOAT · SunSpec Model 102 — Inverter (Split-Phase) · SunSpec Model 103 — Inverter (Three Phase) · SunSpec Model 132 — Volt-Watt · SunSpec Model 130 — HVRTD · SunSpec Model 137 — LVRTC · SunSpec Model 138 — HVRTC · SunSpec Model 136 — HFRT · SunSpec Model 141 — LFRTC · SunSpec Model 142 — HFRTC · SunSpec Model 140 — HVRTX · SunSpec Model 144 — HFRTX · SunSpec Model 203 — wye-connect three phase (abcn) meter · SunSpec Model 204 — delta-connect three phase (abc) meter · SunSpec Model 212 — split single phase (ABN) meter · SunSpec Model 213 — wye-connect three phase (abcn) meter · SunSpec Model 214 — delta-connect three phase (abc) meter · SunSpec Model 303 — Back of Module Temperature Model · SunSpec Model 304 — Inclinometer Model · SunSpec Model 63002 — SunSpec Test Model 2 · SunSpec Model 706 — DER Volt-Watt · SunSpec Model 708 — DER Trip HV · SunSpec Model 710 — DER Trip HF
- Last updated
SunSpec templates
2 via Modbus RTU, 84 via Modbus TCP
SunSpec Model 111 — Inverter (Single Phase) FLOATModbus TCP33 read, 0 write
SunSpec Model 1 — CommonModbus TCP8 read, 1 write
SunSpec Model 10 — Communication Interface HeaderModbus TCP5 read, 1 write
SunSpec Model 101 — Inverter (Single Phase)Modbus TCP45 read, 0 write
SunSpec Model 11 — Ethernet Link LayerModbus TCP8 read, 3 write
SunSpec Model 12 — IPv4Modbus TCP17 read, 12 write
SunSpec Model 120 — NameplateModbus TCP27 read, 0 write
SunSpec Model 121 — Basic SettingsModbus TCP32 read, 20 write
SunSpec Model 122 — Measurements_StatusModbus TCP22 read, 0 write
SunSpec Model 123 — Immediate ControlsModbus TCP26 read, 21 write
SunSpec Model 124 — StorageModbus TCP26 read, 12 write
SunSpec Model 125 — PricingModbus TCP9 read, 6 write
SunSpec Model 126 — Static Volt-VARModbus TCP12 read, 5 write
SunSpec Model 127 — Freq-Watt ParamModbus TCP11 read, 6 write
SunSpec Model 128 — Dynamic Reactive CurrentModbus TCP15 read, 11 write
SunSpec Model 129 — LVRTDModbus TCP11 read, 5 write
SunSpec Model 13 — IPv6Modbus TCP17 read, 12 write
SunSpec Model 131 — Watt-PFModbus TCP12 read, 5 write
SunSpec Model 133 — Basic SchedulingModbus TCP6 read, 2 write
SunSpec Model 134 — Freq-Watt CrvModbus TCP12 read, 5 write
SunSpec Model 135 — LFRTModbus TCP11 read, 5 write
SunSpec Model 139 — LVRTXModbus TCP12 read, 5 write
SunSpec Model 14 — Proxy ServerModbus TCP10 read, 8 write
SunSpec Model 143 — LFRTXModbus TCP12 read, 5 write
SunSpec Model 145 — Extended SettingsModbus TCP10 read, 7 write
SunSpec Model 15 — Interface Counters ModelModbus TCP14 read, 1 write
SunSpec Model 16 — Simple IP NetworkModbus TCP11 read, 8 write
SunSpec Model 160 — Multiple MPPT Inverter Extension ModelModbus TCP9 read, 0 write
SunSpec Model 17 — Serial InterfaceModbus RTU10 read, 6 write
SunSpec Model 18 — Cellular LinkModbus TCP7 read, 5 write
SunSpec Model 19 — PPP LinkModbus TCP11 read, 6 write
SunSpec Model 2 — Basic AggregatorModbus TCP12 read, 0 write
SunSpec Model 201 — Meter (Single Phase) single phase (AN or AB) meterModbus TCP74 read, 0 write
SunSpec Model 202 — split single phase (ABN) meterModbus TCP74 read, 0 write
SunSpec Model 211 — single phase (AN or AB) meterModbus TCP64 read, 0 write
SunSpec Model 220 — Secure AC Meter Selected ReadingsModbus TCP33 read, 0 write
SunSpec Model 3 — Secure Dataset Read RequestModbus TCP59 read, 55 write
SunSpec Model 302 — Irradiance ModelModbus TCP2 read, 0 write
SunSpec Model 305 — GPSModbus TCP8 read, 0 write
SunSpec Model 306 — Reference Point ModelModbus TCP6 read, 0 write
SunSpec Model 307 — Base MetModbus TCP13 read, 0 write
SunSpec Model 308 — Mini Met ModelModbus TCP6 read, 0 write
SunSpec Model 4 — Secure Dataset Read ResponseModbus TCP61 read, 0 write
SunSpec Model 401 — String Combiner (Current)Modbus TCP13 read, 0 write
SunSpec Model 402 — String Combiner (Advanced)Modbus TCP18 read, 0 write
SunSpec Model 403 — String Combiner (Current)Modbus TCP15 read, 0 write
SunSpec Model 404 — String Combiner (Advanced)Modbus TCP23 read, 0 write
SunSpec Model 5 — Secure Write RequestModbus TCP89 read, 87 write
SunSpec Model 501 — Solar ModuleModbus TCP19 read, 3 write
SunSpec Model 502 — Solar ModuleModbus TCP23 read, 3 write
SunSpec Model 6 — Secure Write Sequential RequestModbus TCP90 read, 88 write
SunSpec Model 601 — Tracker Controller DRAFT 2Modbus TCP13 read, 3 write
SunSpec Model 63001 — SunSpec Test Model 1Modbus TCP55 read, 8 write
SunSpec Model 64001 — Veris Status and ConfigurationModbus TCP37 read, 1 write
SunSpec Model 64020 — Mersen GreenStringModbus RTU32 read, 0 write
SunSpec Model 64101 — Eltek Inverter ExtensionModbus TCP9 read, 0 write
SunSpec Model 64111 — Basic Charge ControllerModbus TCP25 read, 0 write
SunSpec Model 64112 — OutBack FM Charge ControllerModbus TCP66 read, 0 write
SunSpec Model 64410 — DC Simulator Control InterfaceModbus TCP36 read, 27 write
SunSpec Model 64411 — AC Simulator Control InterfaceModbus TCP50 read, 16 write
SunSpec Model 64412 — DER Cyber ExploitationModbus TCP45 read, 43 write
SunSpec Model 64413 — PV CurvesModbus TCP5 read, 0 write
SunSpec Model 64414 — DER Simulation ControlsModbus TCP11 read, 8 write
SunSpec Model 64415 — CSIP Client ControlModbus TCP5 read, 3 write
SunSpec Model 7 — Secure Write Response Model (DRAFT 1)Modbus TCP10 read, 1 write
SunSpec Model 701 — DER AC MeasurementModbus TCP72 read, 0 write
SunSpec Model 702 — DER CapacityModbus TCP51 read, 19 write
SunSpec Model 703 — Enter ServiceModbus TCP13 read, 8 write
SunSpec Model 704 — DER AC ControlsModbus TCP45 read, 32 write
SunSpec Model 705 — DER Volt-VarModbus TCP13 read, 4 write
SunSpec Model 707 — DER Trip LVModbus TCP9 read, 2 write
SunSpec Model 709 — DER Trip LFModbus TCP9 read, 2 write
SunSpec Model 711 — DER Frequency DroopModbus TCP12 read, 4 write
SunSpec Model 712 — DER Watt-VarModbus TCP12 read, 4 write
SunSpec Model 713 — DER Storage CapacityModbus TCP9 read, 0 write
SunSpec Model 714 — DER DC MeasurementModbus TCP13 read, 0 write
SunSpec Model 715 — DERCtlModbus TCP7 read, 3 write
SunSpec Model 8 — Get Device Security CertificateModbus TCP4 read, 0 write
SunSpec Model 801 — Energy Storage Base Model (DEPRECATED)3 read, 0 write
SunSpec Model 802 — Battery Base ModelModbus TCP58 read, 6 write
SunSpec Model 803 — Lithium-Ion Battery Bank ModelModbus TCP28 read, 0 write
SunSpec Model 804 — Lithium-Ion String ModelModbus TCP37 read, 2 write
SunSpec Model 805 — Lithium-Ion Module ModelModbus TCP28 read, 0 write
SunSpec Model 806 — Flow Battery ModelModbus TCP3 read, 0 write
SunSpec Model 807 — Flow Battery String ModelModbus TCP31 read, 0 write
SunSpec Model 808 — Flow Battery Module ModelModbus TCP3 read, 0 write
SunSpec Model 809 — Flow Battery Stack Model3 read, 0 write
SunSpec Model 9 — Set Operator Security CertificateModbus TCP93 read, 91 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

SunSpec is an open information model for solar inverters, energy storage, meters, and environmental sensors. Rather than a manufacturer, SunSpec defines a standardised set of Modbus register models (103 Three Phase Inverter, 111/112 Float Inverters, 120 Nameplate, 122 Measurements & Status, 123 Immediate Controls, 124 Storage, and more) that many hardware vendors implement. If your device carries the SunSpec label, these templates give you a drop-in configuration without digging through vendor-specific register maps.
ModbusCloud ships ready-made templates for the full SunSpec model family so you can read nameplate data, live AC and DC measurements, status flags, storage state, and basic settings over Modbus. Whether the device speaks Modbus TCP over Ethernet or RTU over RS485, pick the SunSpec model that matches the firmware and the register addresses, scaling factors, and data types are already mapped. That matters for fleets where installers meet mixed hardware but want one consistent dashboard.
All SunSpec templates are free to browse. Import the model that matches your device into your ModbusCloud portal and read live data within minutes — no register mapping, no combing through SunSpec specification PDFs.
What you can read out
- AC active power and energy totals
- DC voltage, current, and power
- Inverter operating state and event flags
- Battery state of charge and storage limits
- Nameplate ratings and device identification
Typical installations
- Mixed-vendor PV fleets standardised on SunSpec-compliant inverters and meters
- Commercial storage sites where operators need one register model across hardware
- Retrofit projects replacing legacy loggers with standards-based Modbus polling
Knowledge base articles about SunSpec

SunSpec Modbus: one register map for many inverters
SunSpec Modbus is the open register map SMA, Fronius, SolarEdge and Kostal share. The layout, int+SF vs float, the TCP port per brand and reading a mixed fleet.
Fronius Modbus: read a Symo GEN24 over Modbus TCP
Fronius Modbus explained: enable Modbus TCP on the Symo GEN24 on port 502, choose between int+SF and float, read the right SunSpec registers and scale them correctly. Practical guide for solar installers.
SMA Modbus: reading a Sunny Boy over Modbus TCP (installers)
SMA Modbus explained: enable the Modbus TCP server on port 502, choose between the SMA profile (unit ID 3) and SunSpec (unit ID 126), read the right registers, and handle the NaN values at night. Practical guide for installers.
Want to see how it works?